  1. Simulation of board level drop test for wafer level packages

    Reliability of IC packages during drop impact is critical for portable electronic products. Normally, portable products are designed to withstand a few accidental drops without resulting in major mechanical failure. In this study, the ABAQUS/EXPLICIT finite element software is used to perform the …

    nus Repository record for Simulation of board level drop test for wafer level packages (opens in a new tab) Download file for Simulation of board level drop test for wafer level packages (opens in a new tab)

  2. DEVELOPMENT OF DROP-TEST SIMULATION AND RELIABILITY CHARACTERIZATION FOR IC PACKAGES

    Drop impact induced failure, one of the most dominant failure modes for portable electronic products can cause housing damage, components failure and interconnects cracking. It is common that failure modes exist with the damage of the inside small components or tiny structures within the product. …

    nus Repository record for DEVELOPMENT OF DROP-TEST SIMULATION AND RELIABILITY CHARACTERIZATION FOR IC PACKAGES (opens in a new tab) Download file for DEVELOPMENT OF DROP-TEST SIMULATION AND RELIABILITY CHARACTERIZATION FOR IC PACKAGES (opens in a new tab)

  3. FINITE ELEMENT ANALYSIS OF CONFORMABLE CNG TANK – TOPOLOGY OPTIMIZATION AND DROP TEST SIMULATION

    … Phase I tanks. It also presents a brief study on Drop Test simulation of the tank. The Topology optimization analysis was conducted using FEA (Finite element analysis) packages Hypermesh and Optistruct. The results show that optimized tank design has 28 % less mass as compared to the original …

    mtu Repository record for FINITE ELEMENT ANALYSIS OF CONFORMABLE CNG TANK – TOPOLOGY OPTIMIZATION AND DROP TEST SIMULATION (opens in a new tab)

  4. The Reliability Of The Navicular Drop Test and Its Transferability To Dynamic Movement

    Background: Navicular drop can be defined as the distance the navicular tuberosity moves from a standing weight bearing to a standing neutral position, as the subtalar joint moves from a relaxed position to a neutral position. Navicular drop is an important measurement for clinicians used to …

    gsu Repository record for The Reliability Of The Navicular Drop Test and Its Transferability To Dynamic Movement (opens in a new tab)

  5. Drop Test Simulation of a Conformable CNG Tank by Finite Element Analysis using ANSYS

    … (Natural Gas Vehicle) safety standards. Physical drop tests have shown satisfactory results with NGV2 drop test criteria. These tests simulated in HyperMesh/RADIOSS by Sumit Bongir and in Abaqus by Paul Roehm have shown little discrepancies in results compared with physical test results. This …

    mtu Repository record for Drop Test Simulation of a Conformable CNG Tank by Finite Element Analysis using ANSYS (opens in a new tab)

  6. Optimization of mycelium bio-foam packaging design through drop test simulations and environmental impact assessment

    … finite element analysis (FEA) simulations of drop tests on a 32-inch flat-screen TV and a porcelain vase, the study evaluated the impact of MBF properties and design configurations on shock absorption performance. Results demonstrated MBF's ability to protect both products from damage under …

    manitoba Repository record for Optimization of mycelium bio-foam packaging design through drop test simulations and environmental impact assessment (opens in a new tab)

  7. Drop Test Simulation of a Conformable CNG Tank by Finite Element Analysis using HyperMesh/RADIOSS

    … product validation, this tank must pass the NGV2 drop test. Physical drop tests have confirmed satisfactory compliance with NGV2 drop test. It is required to be able to FEA simulate the drop test as close to reality as possible so that design predictions can be made for the next stage of the tank …

    mtu Repository record for Drop Test Simulation of a Conformable CNG Tank by Finite Element Analysis using HyperMesh/RADIOSS (opens in a new tab)

  8. Comparison of Methods Simulating the Ankle Sprain Mechanism:Inversion Drop Test and Landing on a Slanted Surface

    … to investigate the kinematics of two ankle brace testing protocols. They were drop landing on a slanted surface and the inversion drop test. Difference in kinematics and ground reaction forces of drop landing wearing an ankle brace on flat and lateral slant surfaces were also investigated. Eleven …

    ut-knoxville Repository record for Comparison of Methods Simulating the Ankle Sprain Mechanism:Inversion Drop Test and Landing on a Slanted Surface (opens in a new tab)

  9. Parametric Investigation of a Laboratory Drop Test to Simulate Base Acceleration Induced By Wave Impacts of High Speed Planing Craft

    … about wave slamming and simulating them with drop tests. Eventually, a final experiment strongly influenced by the experiment model found in (Protocol 1, 2014) was formulated. Technical drawings were produced which in turn were given to the NSWCCD DN waterfront fabrication shop at Naval …

    odu Repository record for Parametric Investigation of a Laboratory Drop Test to Simulate Base Acceleration Induced By Wave Impacts of High Speed Planing Craft (opens in a new tab)

  10. Implementation of a Drop Test Impact Rig for Dynamic Testing of High Speed Craft Shock Mitigation Seats and Extraction of Modal Parameters

    … injury to the occupants. The need for a standard testing platform and experimental analysis to investigate a seat's effectiveness forms the major objective of research being carried out by Carleton University's Applied Dynamics Laboratory (ADL) in partnership with Defence Research and Development …

    carleton Repository record for Implementation of a Drop Test Impact Rig for Dynamic Testing of High Speed Craft Shock Mitigation Seats and Extraction of Modal Parameters (opens in a new tab)

  11. A NOCSAE DROP TEST/ 3D-FEM STUDY ON THE RELATIONSHIP BETWEEN KINEMATIC RESPONSE OF THE HEAD, HEAD IMPACT CONTACT PRESSURE (HICP) AND KINETIC RESPONSE OF THE BRAIN TO DELINEATE THE RISK OF TRAUMATIC BRAIN INJURIES (TBI).

    … is normal? Probably we might wonder “Are drops which occur at a small height dangerous?” Yes, they can be. Brain injuries are main reason for the fatality in youth [1], and low level falls are one of the most neglected and understated injuries. The main objective of this study is to study …

    mtu Repository record for A NOCSAE DROP TEST/ 3D-FEM STUDY ON THE RELATIONSHIP BETWEEN KINEMATIC RESPONSE OF THE HEAD, HEAD IMPACT CONTACT PRESSURE (HICP) AND KINETIC RESPONSE OF THE BRAIN TO DELINEATE THE RISK OF TRAUMATIC BRAIN INJURIES (TBI). (opens in a new tab)

  12. Describing the Relationship Between Three Ice Hockey Helmet Impact Tests and Reconstructions of Concussive Injuries in Professional Ice Hockey

    … as concussion. This is due to current standard tests, which only represent one head impact event (a fall to the ice) and do not measure rotational head kinematics. It is important that helmets are evaluated using impact conditions that represent how players sustain concussions in ice hockey. The …

    ottawa-retro Repository record for Describing the Relationship Between Three Ice Hockey Helmet Impact Tests and Reconstructions of Concussive Injuries in Professional Ice Hockey (opens in a new tab)

  13. Durability of wood pellets

    … approaches, including Dural, Tumbler and drop test, and established relationship between them. In particular, 1) we developed a robust method that measures durability based on Dural. A series of experiments were conducted using eight different machine settings and four types of pellets. It …

    ubc Repository record for Durability of wood pellets (opens in a new tab) Download PDF for Durability of wood pellets (opens in a new tab)

  14. Vacuum Integrity and Leak Localization in Polymer Composite Manufacturing

    … manufacturers verify integrity with a vacuum-drop test which confirms whether a leak is present but gives no information about where it is located. When the vacuum-drop test fails, the leak is found by a manual search that is slow, depends on skilled operators and scales poorly to large parts. …

    ottawa-retro Repository record for Vacuum Integrity and Leak Localization in Polymer Composite Manufacturing (opens in a new tab)

  15. Analysis of radio controlled airplane landing gear using empirical similitude

    … thesis uses empirical similitude to compare the drop test result of an RC plane landing gear to a large oleo strut landing gear. This is useful to help create novel designs for applications onto large aircraft, as it is difficult to run experiments on the larger system. A drop test rig was …

    texas Repository record for Analysis of radio controlled airplane landing gear using empirical similitude (opens in a new tab)

  16. Characterization and Modification of Helmet Padding System to Improve Shockwave Dissipation

    … fabric was measured using a Dynamic Modulus Tester. There was a significant difference between the sound velocities of the high-performance and commodity fibers. The instrument was also used to investigate the effect of crimping, denier, twist and multiple fiber system on the sound velocity. …

    clemson Repository record for Characterization and Modification of Helmet Padding System to Improve Shockwave Dissipation (opens in a new tab)

  17. Vibration test as a new method for studying the mechanical reliability of solder interconnections under shock loading conditions

    … thesis presents a new large-amplitude vibration test method for studying the reliability of electronic assemblies under mechanical shock loadings. The vibration test has two important advantages as compared to the widely employed JESD22-B111 drop test: firstly, the vibration test is a more …

    aalto Repository record for Vibration test as a new method for studying the mechanical reliability of solder interconnections under shock loading conditions (opens in a new tab)

  18. Inverse dynamic modeling for characterization of spasticity

    … to describe the motion in the pendulum knee drop test. Inverse kinematic modeling is implemented to investigate the pathophysiology of spasticity. Using the equilibrium point hypothesis as a conceptual framework to explain disabled and non-disabled neuromuscular control, it has been …

    njit Repository record for Inverse dynamic modeling for characterization of spasticity (opens in a new tab)

  19. Pre-Irradiation Characterization of Thorium-Uranium Oxide Fuel Samples

    … pore size and distribution analysis, a vertical drop test, wavelength-dispersive X-ray spectroscopy (WDS), combustion analysis and inductively coupled plasma mass spectrometry (ICP-MS). Both the grain size and pore size distribution analyses found their respective scope to be of consistent …

    tamu Repository record for Pre-Irradiation Characterization of Thorium-Uranium Oxide Fuel Samples (opens in a new tab)

  20. Effect of Microgravity on the Development and Structure of Fire Whirls

    … on the flame. Results are presented from tests performed at the NASA Glenn Research Center Zero Gravity Research Facilities’ 5.18 s drop tower. Fire whirls were generated over a paraffin wax wick in 1 g using two offset half cylinders. A vertical bank of fans was placed at each inlet to …

    maryland Repository record for Effect of Microgravity on the Development and Structure of Fire Whirls (opens in a new tab)