Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 28 for “"Dry cooling"”.

  1. The Effect of Wind on Multiple, Short, Natural-draft Dry Cooling Towers

    … plants in arid areas necessitates the use of dry cooling systems to reject heat from the condenser. Previous research has shown that the capacity of short natural draft dry cooling towers (NDDCTs), used as condensers for CST plants, can be significantly influenced by the prevailing wind …

    auckland-tech Repository record for The Effect of Wind on Multiple, Short, Natural-draft Dry Cooling Towers (opens in a new tab)

  2. An estimation of the performance limits and improvement of dry cooling on trough solar thermal plants

    … for the Las Vegas vicinity with conventional wet cooling and conventional dry cooling cases considered separately using this software. TMY2 data are used for this location for this purpose. Similarly, the same studies are carried out for "ideal" cooling systems as a compariSon It turned out that …

    unlv Repository record for An estimation of the performance limits and improvement of dry cooling on trough solar thermal plants (opens in a new tab) Download PDF for An estimation of the performance limits and improvement of dry cooling on trough solar thermal plants (opens in a new tab)

  3. Experimental Investigation of Latent Heat Energy Storage System (LHTESS) for Enhancing Performance of Dry-Cooling Powerplant

    … future - these conventional techniques for water cooling of thermal power-plants will become unsustainable in various geographical regions that have scarcity of water resources. This is expected to arise from a combination of environmental concerns, increased water demand due to population growth, …

    tamu Repository record for Experimental Investigation of Latent Heat Energy Storage System (LHTESS) for Enhancing Performance of Dry-Cooling Powerplant (opens in a new tab)

  4. Economics of Possible Energy Sector Roles in a Food Energy Water Stressed Region

    … possibilities for retrofitting existing cooling systems of power plants to reduce water withdrawal and consumption are considered. To evaluate water related actions by regional power plants, an examination is done of the water savings and associated cost arising from potential changes in …

    tamu Repository record for Economics of Possible Energy Sector Roles in a Food Energy Water Stressed Region (opens in a new tab)

  5. Sustainable energy systems : the environmental footprints of electricity generation systems : mechanisms for managing electricity, water resources and air quality

    … generally greater than the cost of implementing dry cooling in the same facilities at high electricity demand levels, but comparable to dry cooling at low to moderate demand levels. Finally, while changes in total emissions can be used as a surrogate for air quality impacts, actual changes in air …

    texas Repository record for Sustainable energy systems : the environmental footprints of electricity generation systems : mechanisms for managing electricity, water resources and air quality (opens in a new tab)

  6. The South African water management framework : Lethabo power station as a case study

    … the same policies and strategies. For example, dry cooling technologies were initially only designed for water scarce areas, but Eskom has committed to implement dry cooling technology at all new build power stations even though it is more expensive in terms of capital cost and maintenance. For …

    nwu-za Repository record for The South African water management framework : Lethabo power station as a case study (opens in a new tab)

  7. Development of Scalable and Tunable Super- Hydrophilic and - Hydrophobic Coatings on the CU Substrate for Phase Change Heat Transfer Applications

    … objective of the first section is to enhance the dry cooling technology which is widely used in industrial applications such as in the air side of power plants, AC unit, or electronic cooling. However, the thermal dissipation performance is limited with low heat transfer coefficients (HTCs) due to …

    south-carolina Repository record for Development of Scalable and Tunable Super- Hydrophilic and - Hydrophobic Coatings on the CU Substrate for Phase Change Heat Transfer Applications (opens in a new tab)

  8. Design and experimental testing of metamaterial-based agitators

    … or huge water consumption of traditional cooling methods, many power plants are looking for a way that is eco-friendly and high efficient but low-cost to retrofit their current cooling system. This study aims to explore innovative solutions to enhance heat transfer efficiency based on …

    missouri Repository record for Design and experimental testing of metamaterial-based agitators (opens in a new tab)

  9. Numerical and Experimental Analysis of Air-Cooled Condensers

    … project is to numerically and experimentally dry cooling process in air-cooled condensers (ACCs) designed for concentrated solar power (CSP) applications. This effort is driven by the growing economic and political pressure to reduce water consumption during power generation due to limited …

    unlv Repository record for Numerical and Experimental Analysis of Air-Cooled Condensers (opens in a new tab) Download PDF for Numerical and Experimental Analysis of Air-Cooled Condensers (opens in a new tab)

  10. Caracterização de fitas supercondutoras 2G HTS em regime de Flux flow

    … techniques were used for the construction of a dry cooling current lead.

    brazil-uerj Repository record for Caracterização de fitas supercondutoras 2G HTS em regime de Flux flow (opens in a new tab)

  11. Cooling the steam power plant condenser using a vapor compression refrigeration system

    … consume more than 7.6 x 106 L/day of water for cooling (equivalent plant capacity >250 MW) must consider alternate technologies to determine the best available technology for rejecting the waste heat. A steam condenser is an essential part of a steam power plant. Steam condensation occurs in a …

    msu Repository record for Cooling the steam power plant condenser using a vapor compression refrigeration system (opens in a new tab)

  12. Hydrogen-water collision: Quantifying the water demands of the green hydrogen economy

    … of eight lower with evaporative compared to dry cooling but required 300 to 500% more water. However, if desalinated seawater is used as feedstock, thermal seawater desalination can simultaneously serve the electrolyser cooling and water demands and generates 50-270 LH2O/kgH2 surplus and for …

    unsw Repository record for Hydrogen-water collision: Quantifying the water demands of the green hydrogen economy (opens in a new tab)

  13. Optimisation criteria of a Rankine steam cycle powered by thorium HTR

    … cement production plant is unknown, both wet and dry cooling tower options are investigated. An overall average ambient temperature of India is used as input for the cooling tower calculations. EES software is used to construct a simulation model with the capability of optimising the Rankine cycle …

    nwu-za Repository record for Optimisation criteria of a Rankine steam cycle powered by thorium HTR (opens in a new tab)

  14. Numerical Analysis on Convective Cooling Augmented by Evaporative Heat and Mass Transfer for Thermal Power Plant Application

    … a numerical study on the effect of evaporative cooling on the augmentation of forced convective cooling. In recent years, on-demand phase change boosted cooling has drawn major interest where convective heat transfer is augmented/aided by evaporative heat and mass transport processes. This dual …

    south-carolina Repository record for Numerical Analysis on Convective Cooling Augmented by Evaporative Heat and Mass Transfer for Thermal Power Plant Application (opens in a new tab)

  15. Design of an Annular Disc-shaped Heat Pipe for Air-cooled Steam Condensers

    … condensers (ACC) in replace to the typical water-cooling methods of once-through cooling and the surface condenser/wet-cooling tower combination. Although the ACC is a dry cooling method, the industry is quite hesitant to switch over to ACC mainly for three reasons: (a) lower power output, (b) …

    ucf Repository record for Design of an Annular Disc-shaped Heat Pipe for Air-cooled Steam Condensers (opens in a new tab)

  16. Design and Preliminary Evaluation of a Supercritical Carbon Dioxide Brayton Cycle for Solar Dish Concentrator Clean Energy Production

    … the UNLV Machine Shop. This, in conjunction with dry cooling, compounds the capacity for increased efficiency with trivial water consumption and decreased environmental and geographical footprints. Photographic flux mapping was used to provide solar flux information leading to the custom design …

    unlv Repository record for Design and Preliminary Evaluation of a Supercritical Carbon Dioxide Brayton Cycle for Solar Dish Concentrator Clean Energy Production (opens in a new tab) Download PDF for Design and Preliminary Evaluation of a Supercritical Carbon Dioxide Brayton Cycle for Solar Dish Concentrator Clean Energy Production (opens in a new tab)

  17. Experimental Investigation of a Compact Heat Exchanger for Thermal Energy Storage in Sustainability Applications (for Mitigating Energy-Water Nexus Issues)

    … phase change materials (PCM), for supplementing cooling loads of a dry-cooling platform. The melting and solidification times for a fixed mass of a chosen PCM was estimated from temperature measurements (recorded experimentally using a digital data acquisition system) performed in this study. A …

    tamu Repository record for Experimental Investigation of a Compact Heat Exchanger for Thermal Energy Storage in Sustainability Applications (for Mitigating Energy-Water Nexus Issues) (opens in a new tab)

  18. A Comparative Study of Cooling System Parameters in U.S. Thermoelectric Power Plants

    … purpose of this study is to provide and analyze cooling system parameters using 2008 data provided by the Energy Information Administration. Additionally, the cost of water saved among different categories of power plants is calculated. In general, the conditions which cause cooling systems to …

    vt Repository record for A Comparative Study of Cooling System Parameters in U.S. Thermoelectric Power Plants (opens in a new tab)

Page 1 of 2