Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 113 for “"Dual modality"”.

  1. Dual-modality thermoacoustic and photoacoustic imaging

    … and photoacoustic imaging techniques to achieve dual-contrast: microwave and light absorption), non-ionizing, low-cost, high-resolution, three-dimensional breast imaging. We have also developed a novel concept of using a negative acoustic lens to increase the acceptance angle of an unfocused …

    wustl Repository record for Dual-modality thermoacoustic and photoacoustic imaging (opens in a new tab)

  2. Radiolabeled magnetic nanoparticles for dual-modality disease imaging

    Dual modality contrast agents (DMCAs), such as radiolabeled magnetic nanoparticles (MNPs), are promising candidates for a number of diagnostic applications, since they combine the advantages of two different imaging modalities, namely single photon emission computed tomography (SPECT) or positron …

    greece Repository record for Radiolabeled magnetic nanoparticles for dual-modality disease imaging (opens in a new tab)

  3. An image reconstruction algorithm for a dual modality tomographic system.

    … describes an investigation into the use of dual modality tomography to measure component concentrations within a cross-section. The benefits and limitations of using dual modality compared with single modality are investigated and discussed. A number of methods are available to provide …

    sheffield-hallam Download PDF for An image reconstruction algorithm for a dual modality tomographic system. (opens in a new tab)

  4. Dual modality optical coherence tomography : Technology development and biomedical applications

    … tomography (OCT) is a cross-sectional imaging modality that is widely used in clinical ophthalmology and interventional cardiology. It is highly promising for in situ characterization of tumor tissues. OCT has high spatial resolution and high imaging speed to assist clinical decision making in …

    njit Repository record for Dual modality optical coherence tomography : Technology development and biomedical applications (opens in a new tab)

  5. Design and validation of a dual modality brain-computer interface

    … on many subjects, and the effectiveness of each modality as well as the combined NIRS-tEEG was statistically evaluated. In comparison to each of the modalities, the dual-modality accuracy was found to be significantly higher.

    freiburg-diss Repository record for Design and validation of a dual modality brain-computer interface (opens in a new tab)

  6. Development of Iron Oxide Based Nanoparticles as Dual-Modality Imaging Probes

    Dual-modality (MR/nuclear) imaging can combine exquisite anatomical resolution with superior molecular sensitivity, and significantly facilitate the accuracy of cancer diagnosis. However, the application of this technique is hampered by the paucity of sensitive dual-modality imaging probes that …

    utswmed Repository record for Development of Iron Oxide Based Nanoparticles as Dual-Modality Imaging Probes (opens in a new tab)

  7. Dual-modality optical-dielectric cytometer for microplastic and single-cell analysis

    … dielectric properties of particles in flow. The dual-modality optical-dielectric cytometer utilizes a high-speed camera focused in a microfluidic channel with integrated coplanar electrodes. A polarizable particle placed in a non-uniform electric field experiences a translational motion, altering …

    manitoba Repository record for Dual-modality optical-dielectric cytometer for microplastic and single-cell analysis (opens in a new tab)

  8. MODELING OF DUAL MODALITY PROBE FOR CONCURRENTLY COLLECTING MR AND OPTICAL SPECTRA

    … characteristic in situ. Nowadays, combining multimodality sensors on a single probe is an emerging and promising trend in multimodality approach. The aim of this study is to create simulations for both MR Spectroscopy and Optical Spectroscopy in order to find out the effective areas of the …

    houston Repository record for MODELING OF DUAL MODALITY PROBE FOR CONCURRENTLY COLLECTING MR AND OPTICAL SPECTRA (opens in a new tab)

  9. PET/MR imaging of atherosclerotic plaque and tumor using dual modality SPIOS

    … emission tomography (PET). Our results show that dual modality SPIOs with active targeting mediated by affinity ligands can be a great tool in molecular imaging and diagnosis of early stage plaque and tumor.

    gatech Repository record for PET/MR imaging of atherosclerotic plaque and tumor using dual modality SPIOS (opens in a new tab)

  10. Dual Modality Initiations and Subsequent Interactive Structure in Dyads With Deaf Infants

    Successful interaction requires mutual understanding of signals which are used and responded to appropriately (Schaffer, Collis, & Parsons, 1977) in a variety of modes. Predictable responses by each member of the dyad help to sustain a dialogue in which each member's activity is intricately related …

    uiuc Repository record for Dual Modality Initiations and Subsequent Interactive Structure in Dyads With Deaf Infants (opens in a new tab)

  11. Dual modality tomography for the monitoring of constituent volumes in multi-component flows.

    … describes an investigation into the use of dual modality tomography to monitor multi-component flows. The concept of combining two modalities for this purpose evolved from a desire by the Water Research Council to determine volume flow rates of the major components of sewage. No single …

    sheffield-hallam Download PDF for Dual modality tomography for the monitoring of constituent volumes in multi-component flows. (opens in a new tab)

  12. Dual Modality Optical Coherence Tomography and Multispectral Fluorescence Imaging for Ovarian Cancer Detection

    … study evaluates the feasibility and design of dual modality, multispectral fluorescence imaging (MFI) and optical coherence tomography (OCT) endoscopes for improved ovarian cancer screening. The study is broken up into three sections. In the first study MFI is validated in an ex vivo imaging …

    arizona-thes Repository record for Dual Modality Optical Coherence Tomography and Multispectral Fluorescence Imaging for Ovarian Cancer Detection (opens in a new tab)

  13. Design and Application of a Dual-Modality Small Animal SPECT and Micro-CT System

    … and the construction and implementation of a dual-modality imaging system is described. An ordered subset-expectation maximization reconstruction utilizing a voxel-driven approach that incorporates the detector response and a 5 mm pinhole collimator was evaluated using in silico and …

    marquette Repository record for Design and Application of a Dual-Modality Small Animal SPECT and Micro-CT System (opens in a new tab)

  14. Dual-modality Smartphone-based Fiber-optic Microendoscope System for Early Detection of Cervical Neoplasia

    … we report the design and development of a dual-modality fiber-optic microendoscope system (SmartME) that integrates high-resolution fluorescence imaging (FLI) and quantitative diffuse reflectance spectroscopy (DRS) onto a smartphone platform. A smartphone App has also been developed to …

    marquette Repository record for Dual-modality Smartphone-based Fiber-optic Microendoscope System for Early Detection of Cervical Neoplasia (opens in a new tab)

  15. Design and development of a prototype of dual modality PET/optical breast cancer margin specification imager

    … margin in the volume of the tissue sample. The dual modality PET/optical breast cancer specification imager uses a pair of small PET detectors to measure the bioactivity of an excised sample of tissue. A co-registered optical image is taken to allow the surgeon to visually correlate the position …

    wvu Repository record for Design and development of a prototype of dual modality PET/optical breast cancer margin specification imager (opens in a new tab)

  16. Development and Optimization of a Dedicated Dual-Modality SPECT-CT System for Improved Breast Lesion Diagnosis

    … this thesis is to characterize and implement a dual-modality SPECT-CT dedicated breast imaging system that can overcome these limitations and integrate both metabolic and anatomical information to further improve the visual quality and quantitative accuracy over independent systems …

    duke Repository record for Development and Optimization of a Dedicated Dual-Modality SPECT-CT System for Improved Breast Lesion Diagnosis (opens in a new tab)

  17. A dual modality, DCE-MRI and x-ray, physical phantom for quantitative evaluation of breast imaging protocols

    … In this study, we developed and characterized a dual-modality, x-ray and DCE-MRI, anthropomorphic breast phantom for the quantitative assessment of breast imaging protocols. X-ray properties of the phantom were quantitatively compared with patient data, including attenuation coefficients, which …

    maryland Repository record for A dual modality, DCE-MRI and x-ray, physical phantom for quantitative evaluation of breast imaging protocols (opens in a new tab)

Page 1 of 6