Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 22 for “"Dual plane"”.
-
A Study of Ship Airwakes Using Dual Plane Stereoscopic PIV
… was measured using a novel time-dependent, dual plane, stereoscopic particle image velocimetry approach. Two flow planes over the flight deck, one parallel and one perpendicular to the free-stream were simultaneously measured. Measurements were carried out over four such pairs of …
-
Integration of Dual-plane co-RASOR MR Imaging into Radiation Therapy Planning
… and paramagnetic seeds. This allowed individual visualization of a low dose rate (LDR) brachytherapy seed and a gold fiducial marker. Phantom validation showed that each seed contains its maximal CNR in opposing frequency regions. The relative difference between global and local maxima in …
-
Studies in wall turbulence using dual plane particle image velocimetry and direct numerical simulation data.
… first part of this thesis deals with the use of Dual Plane Particle Image Velocimetry (DPPIV) to understand the organization of vortex structures in the logarithmic region of turbulent boundary layer and channel flows. DPPIV provides the full velocity gradient tensor in a plane parallel to the …
-
Single- and Dual-Plane Automatic Balancing of an Elastically-Mounted Cylindrical Rotor with Considerations of Coulomb Friction and Gravity
This work treats dual-plane automatic ball balancing of elastically-mounted cylindrical rotors. The application is primarily to systems with a vertically-oriented single-bearing support, but extension is also made to horizontally-oriented single-bearing support as typically found in a vehicle …
-
Comparison of RANS Modeling to Dual-Plane PIV Measurements of the Turbulent Tip Vortex Trailed from a Hovering Rotor
… computational results were compared to detailed, dual plane Particle Image Velocimetry (PIV) measurements of a turbulent tip vortex trailed from a single-bladed rotor. The work investigated both the required mesh resolution and most suitable turbulence closure models with rotational/curvature …
-
Evolution of eddies and packets in turbulent boundary layers.
… new method applied on the streamwise/spanwise plane had a good performance on vortex identification, which was tested by two Direct Numerical Simulation (DNS) of channel flow at Re#28; = 590 and 934, and one Dual-Plane Particle Image Velocimetry (PIV) data set of boundary layer at Re#28; = …
-
DESIGN AND ANALYSIS OF HYBRID DRIVEN CONTINUUM ROBOT WITH VARIABLE STIFFNESS CAPABILITY
… hybrid-driven continuum robot with novel dual-plane constraint design that is easily extensible to multiple sections. The variable stiffness mechanism has a stiffness of range of at least 278%. To characterize the robot, statics and dynamics models were proposed. A verification experiment …
-
Design of Tunable Beamforming Networks Using Metallic Ridge Gap Waveguide Technology
… networks. The Butler matrix is designed using a dual-plane topology to avoid using crossovers. Ridge gap waveguide technology is chosen among different transmission lines to implement the Butler matrix for several reasons: It does not need dielectrics to operate, so its power handling capacity is …
-
Krūtų rekonstrukcija po mastektomijos: pagrindiniai metodai, metodo pasirinkimą lemiantys veiksniai, rezultatai, komplikacijos /
… be done epipectorally, subpectorally or using dual-plane technique. Breast reconstruction with autologous flaps is favoured method because of better patient satisfaction, more natural looking breast and sensation. Autologous reconstruction is suitable for patients with larger or average-sized …
-
MRI methods for predicting response to cardiac resynchronization therapy
… allows us to project the LV lead location from dual-plane fluoroscopy onto MR measurements of cardiac function. By applying these techniques in patients undergoing CRT, we were able to investigate the relationship between regional dyssynchrony, LV pacing lead location, and CRT response.
-
Advanced Laser Diagnostics Development for Stereoscopic Imaging of Gaseous High Speed Flows
… the development of next-generation VENOM, i.e., dual-plane stereoscopic VENOM, for unprecedented characterization of fluid elements in three dimensions.
-
Assessment of Normal Knee Kinematics Using High-Speed Stereo-Radiography System
… to describe knee kinematics in healthy individuals for comparison in diagnosis of pathology and understanding treatment to restore normal function. However measuring the in vivo dynamic biomechanics in 6 degrees of freedom with an accuracy that is acceptable has been shown to be technically …
-
Quantitative analysis of cell mechanics with a focus on human induced pluripotent stem cell-derived cardiomyocytes (hipsc-cms)
… parameters. An advanced workflow combining TFM, dual-plane imaging, and finite element analysis (FEA) quantified hiPSC-CM contractile behavior, highlighting the critical roles of substrate stiffness and micropatterning in modulating cellular mechanics. Micropatterning improved directional force …
-
Measurement and visualisation of slurry flow using electrical resistance tomography
… technique, in which a high performance dual-plane Electrical Resistance Tomography (ERT) system is employed with a capability of acquiring data at a rate of 1000 dual-frames per second. It also proposes an ERT based technique, which combines the ERT and an Electromagnetic Flow meter …
-
Application of Parallel Imaging to Murine Magnetic Resonance Imaging
… detuning switches. The unbalanced feed of this "dual-plane pair" element also eliminates the need for baluns in this case. The use of the element design in a 10-channel adjustable array coil for mouse imaging is presented, styled as a human cardiac top-bottom half-rack design. The design and …
-
Reliable Inference of Functional Connectivity Measures from Two-Photon Calcium Imaging Data
… the spatial maps of directed interactions in dual-plane (L4 and L2/3) recordings combined with holographic optogenetic stimulation of mouse A1. Directed links (estimated with a Monte Carlo GC procedure) are mapped using GPRZ to produce connection maps and region-level statistics. We find that …
-
Analysis of novel high-performance switch architectures for broadband-ISDN.
… limitation of the input buffered switch, a dual plane switch architecture is presented, where each plane is a nonblocking switch with input buffers.
-
Novel Machine Learning Methods for Prostate Image Analysis
… the capability of modern ultrasound systems for dual-plane scanning. Specifically, we use modern image stitching and matching techniques to infer the relative positions of images in the sagittal direction. This allows us to determine the spatial relative positions of transverse images and …
-
Experimental Investigations on Impinging Liquid Jets with Gas Entrainment
… and length. Results were validated using dual-plane x-ray computed tomography. Results were in agreement with the ones obtained from the wire-mesh sensors and approximately four to six times smaller than predictions found in related publications. Instantaneous as well as time-averaged …
Page 1 of 2