Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 34 for “"Dual-Energy Computed Tomography"”
-
Addressing current limitations in dual-energy computed tomography
Dual-energy CT (DECT) provides better material differentiation compared to conventional CT. However, DECT is fundamentally limited by noise amplification and the need for dual dataset acquisition. Noise amplification during signal decomposition significantly limits utility of DECT basis material …
-
Advances in dual-energy computed tomography imaging of radiological properties
Dual-energy computed tomography (DECT) has shown great potential in the reduction of uncertainties of proton ranges and low energy photon cross section estimation used in radiation therapy planning. The work presented herein investigated three contributions for advancing DECT applications. 1) A …
-
Noise Reduction And Information Extraction Of Dual-Energy Computed Tomography Images
With every new generation of computed tomography machinery, big improvements in terms of image quality and acquisition speed were achieved. Nonetheless, a persistent feature of the CT remained: the single energy acquisition of images, which results in images where materials of similar density …
-
Functional and Molecular Imaging Using Nanoparticle Contrast Agents for Dual-Energy Computed Tomography
<p>X-ray computed tomography (CT) is one of the most useful diagnostic tools for clinicians, with widespread availability, fast scan times, and low cost. CT imaging can reveal a patient’s anatomy in exquisite detail and is extremely useful in the diagnosis of a wide variety of diseases. However, CT …
-
Single-Scan Dual-Energy Computed Tomography Using Static Detector Modulation: A Simulation Study
Dual-energy computed tomography (DECT) is an advanced medical imaging technology that offers superior material differentiation capabilities by scanning patients using X-ray beams with two different energy spectra. However, DECT is inherently constrained by noise amplification and the necessity for …
-
Dual-Energy Computed Tomography for Accurate Stopping-Power Prediction in Proton Treatment Planning
Derzeitige Reichweiteunsicherheiten in der Protonentherapie verhindern das vollständige Ausschöpfen ihrer physikalischen Vorteile. Ein wesentlicher Anteil ist dabei auf die Vorhersage der Reichweite mittels Röntgen-Computertomographie (CT) zurückzuführen. Um die CT-bezogene Unsicherheit zu …
-
Basis Vector Model Method for Proton Stopping Power Estimation using Dual-Energy Computed Tomography
… stoichiometric calibration method using single-energy computed tomography (SECT) images, which in principle may introduce large intrinsic uncertainties into estimation results. One major factor that limits the performance of SECT-based methods is the Hounsfield unit (HU) degeneracy in the …
-
Dual-Energy Computed Tomography Scan and Color Doppler Twinkling Artifact of Canine Uroliths to Determine Urolith Fragility by Laser Lithotripsy.
… fragmentation of uroliths using laser energy. However, not every patient is considered for lithotripsy as there are several factors that determine whether a candidate is amenable to laser lithotripsy. The objectives of this study were to 1) Determine whether uroliths in a synthetic …
-
Utilization Of Dual Energy Computed Tomography Based Metal Artifact Reduction To Improve Radiation Treatment Planning In Patients With Implanted High-Z Materials
High quality computed tomography (CT) scans are integral to the successful cancer radiation therapy treatment plan. Metal streak artifact in the CT image originates when a high density medical implant (dental, orthopedic, etc.) disproportionally attenuates the imaging beam and corrupts the imaging …
-
Identification of Intracranial Lesions With Dual-Energy Computed to mography and Magnetic Resonance Phase Imaging
On conventional Single-energy Computed Tomography (SECT), lesions with an attenuation greater than 100 Hounsfield Units (HU) can be definitively diagnosed as calcification. However, low-density calcifications and hemorrhage may have overlapping attenuation ranges between 40 and 100 HU and, …
-
Αιμοδυναμική μελέτη του ανευρυσματικού σάκου μετά την ενδαγγειακή αποκατάσταση ανευρύσματος με σύγχρονες τεχνικές ιατρικής απεικόνισης
… purpose the following techniques were used : A. Dual-energy computed tomography, B. Perfusion imaging and C. Radiomic analysis and artificial intelligence algorithms.The study’s conclusions are encouraging, showing that functional imaging with quantitative assessment of type II endoleak is just a …
-
Deep Learning for Medical Imaging in a Biased Environment
… about human physiology and data derived from dual energy computed tomography scans. In this dissertation, we address the gaps in the radiology literature by introducing new tools, testing strategies, and methods to mitigate the influence of dataset biases.
-
Διαμόρφωση συστήματος πλοήγησης με δεδομένα από εγκάρσιες απεικονιστικές μεθόδους για την ακριβή τοποθέτηση ραδιενεργού πλάκας σε ασθενείς που υποβάλλονται σε βραχυθεραπεία
… with ruthenium-106 (106Ru) plaque based on individualized parameter of ocular geometry. Moreover, to investigate the possibility of creating fusion images from magnetic tomography (in the preoperative period) and special protocol of dual energy computed tomography (DECT) (in the postoperative …
-
Three-Dimensional Medical Image Registration with Applications in Proton Therapy
… In clinical proton therapy dose planning, dual-energy computed tomography (DECT) has notably improved the accuracy of estimating the stopping-power ratio map, reducing proton beam range uncertainty. To address the inter-scan motion artifacts inherent in sequential DECT acquisition, we …
-
Comparison between Dual-Energy-CT perfusion imaging and perfusion-weighted SElf-gated Non-Contrast-Enhanced FUnctional MR imaging of the lung in patients with pulmonary artery embolism
… and an even more common clinical suspect. The computed tomography pulmonary angiogram (CTPA) is the main medical imaging tool used to diagnose a suspected case of PE. To gain a better impression of the effects of a PE on the perfusion and hence the gas exchange, a functional imaging method is …
-
Upscaling Lithology and Porosity Types from Microscopic to Core Domain with Thin Section Petrography, Dual Energy CT, and Rock Types: Creation of Diagenesis and Porosity Type Logs
… and porosity from thin sections to cores using dual energy and multi-scale CT. A new rock typing approach (Genetic Rock Typing) is proposed to upscale diagenetic minerals and pore types, from thin sections to the core domain, to create a diagenesis log. A newly acquired large collection of Late …
-
Performance Evaluation of Material Decomposition Using Rapid Kvp-Switching Dual-Energy Ct For Assessing Bone Mineral Density
… bone, and has previously been characterized with dual-energy x-ray absorptiometry (DXA) or single-energy computed tomography (SECT). Dual-energy computed tomography (DECT) is able to create two three-dimensional sets of images representing the densities of two materials in a given basis pair. DECT …
-
Skeletal-wide heterogeneity of cancellous bone and methods to assess in vivo
… the skeletons of both humans (using whole-body dual energy computed tomography imaging (DECT)) and mice (using micro computed tomography (microCT)). Mice, clinical trial patients, and recently deceased donors were imaged, non-invasively, using a wide array of novel imaging modalities. MicroCT …
-
Porous Topography Dependence of Mechanical properties and Biological Responses for 3D Printed Stainless Steel and Modified Bioimplant Devices
… femur, and a qualitative analysis on femur using Dual Energy Computed Tomography (DECT), Computed Tomography (CT), and Volume Rendering Technology (VRT) shows a relatively good bone growth after implantation of both lattice samples and modified samples. Tissues are also sliced and evaluated by …
Page 1 of 2