Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 45 for “"Ductility demand"”.

  1. Three Dimensional Dynamic Response of Reinforced Concrete Bridges Under Spatially Varying Seismic Ground Motions

    … hinges located at the pier end zones. The ductility demand at each pier is determined from the bidirectional rotations occurring at the plastic hinges during the seismic response evaluation of the bridge models. Variability of the soil characteristics along the length of the bridge is …

    arizona-thes Repository record for Three Dimensional Dynamic Response of Reinforced Concrete Bridges Under Spatially Varying Seismic Ground Motions (opens in a new tab)

  2. The Effects of Diaphragm Flexibility on the Seismic Response of One-Storey Steel Buildings

    … the period of the building, magnifies the ductility demand on the lateral load resisting system (LLRS), and changes the manner in which the inertia forces are distributed along the length of the diaphragm. These effects are influenced by the manner in which the LLRS responds. In particular, …

    carleton Repository record for The Effects of Diaphragm Flexibility on the Seismic Response of One-Storey Steel Buildings (opens in a new tab)

  3. Torsional response of multi-storey buildings using 3-D inelastic dynamic analysis

    … is done by calculating the displacements and ductility demand of several practical five storey eccentric buildings designed according to the 1985 code, and comparing the response to similar non eccentric buildings. The analysis is carried out using a modified version of the computer program …

    ubc Repository record for Torsional response of multi-storey buildings using 3-D inelastic dynamic analysis (opens in a new tab) Download PDF for Torsional response of multi-storey buildings using 3-D inelastic dynamic analysis (opens in a new tab)

  4. Seismic Response of Inelastic Structures Subjected to Bidirectional Excitations

    … could seriously underestimate the displacement ductility demand. It is recommended herein that such structures to be designed remain elastic or almost elastic under expected earthquake disturbances. Taking the interaction effect and the critical orientation of ground motion components into …

    mcmaster Repository record for Seismic Response of Inelastic Structures Subjected to Bidirectional Excitations (opens in a new tab)

  5. Nonlinear Response of Torsionally Coupled Structures

    … The main concern herein is the peak ductility demand especially at edges.</p> <p>A limited parametric study is undertaken to identify trends in peak ductility demand. The effects of torsional coupling in nonlinear systems are also investigated. Real earthquake records as well as an …

    mcmaster Repository record for Nonlinear Response of Torsionally Coupled Structures (opens in a new tab)

  6. Seismic Response of Steel Frames with Bilinear and Flag Shaped Hysteretic Braces

    … (EDDs), which effectively lower the seismic demand on main structural components by absorbing a portion of the seismic input energy. This energy is often absorbed through the yielding of metallic components within these devices. Examples of traditionally used metals are steel and lead which …

    mcmaster Repository record for Seismic Response of Steel Frames with Bilinear and Flag Shaped Hysteretic Braces (opens in a new tab)

  7. Inelastic response of torsionally unbalanced multistorey shearwall buildings designed using elastic static and dynamic analyses

    … and control the increased displacement and ductility demand on edge-elements of vertically uniform, multistorey, shear core buildings, designed to yield in flexure, with varying degrees of asymmetric stiffness distribution. A comparison is made between the elastic and nonlinear time history …

    ubc Repository record for Inelastic response of torsionally unbalanced multistorey shearwall buildings designed using elastic static and dynamic analyses (opens in a new tab) Download PDF for Inelastic response of torsionally unbalanced multistorey shearwall buildings designed using elastic static and dynamic analyses (opens in a new tab)

  8. Direct Design of Reinforced Concrete Slabs Using Non Elastic Stress Fields

    … the effect on serviceability limit and ductility demand of using non elastic stress fields. This is the main object of the present work. The work divides into two convenient parts: i-Determination of elasto-plastic stress fields as input to Wood-Armer equations. This is accomplished …

    glasgow Download PDF for Direct Design of Reinforced Concrete Slabs Using Non Elastic Stress Fields (opens in a new tab)

  9. A comparison of the structural response to synthetic earthquake ground motions compatible with central eastern United States attenuation models.

    … Hazard Maps. Specifically, it compares the ductility demands induced by these synthetic earthquake records via nonlinear time history analysis conducted on single degree of freedom systems of various natural frequencies. The synthetic ground motions generated for the study are compatible …

    louisville Repository record for A comparison of the structural response to synthetic earthquake ground motions compatible with central eastern United States attenuation models. (opens in a new tab)

  10. Effect of anchorage slip and inelastic shear on seismic response of reinforced concrete frames.

    … The program is enhanced with calculations of ductility demand and energy dissipation factors. Related input and output features of the program are also enhanced. In the final phase of the project, the enhanced computer program is used to determine the seismic response of three reinforced …

    ottawa-retro Repository record for Effect of anchorage slip and inelastic shear on seismic response of reinforced concrete frames. (opens in a new tab)

  11. The modified substitute structure method as a design aid for seismic resistant coupled structural walls

    … is presented as a design aid which evaluates ductility requirements and deflections to determine the suitability of a reinforced concrete structural wall to withstand an anticipated siesmic disturbance. The procedure is analogous to elastic modal analysis but is an iterative technique which …

    ubc Repository record for The modified substitute structure method as a design aid for seismic resistant coupled structural walls (opens in a new tab) Download PDF for The modified substitute structure method as a design aid for seismic resistant coupled structural walls (opens in a new tab)

  12. Impacts of Cascadia Subduction Zone M9 Earthquakes on Bridges in Washington State: SDOF Idealized Bridges

    … Database (UW-PEER 2020).4. The deformation demands for pre-1976 and 1976-present bridges were estimated for 30 M9 scenarios, the 10 locations, N-S and E-W directions, 120 site profiles (sorted into four site categories) and 18 periods. Both the response of systems with mean strengths and …

    washington Repository record for Impacts of Cascadia Subduction Zone M9 Earthquakes on Bridges in Washington State: SDOF Idealized Bridges (opens in a new tab)

  13. Inelastic torsional seismic analysis of frame buildings

    … are developed to estimate the curvature ductility demand in each case, which is considered to be the basic indicator of potential damage. PITSA is based upon a "substitute damping ratio" which is intended to represent the loss of energy due to hysteresis. The relationship of this factor …

    ubc Repository record for Inelastic torsional seismic analysis of frame buildings (opens in a new tab) Download PDF for Inelastic torsional seismic analysis of frame buildings (opens in a new tab)

  14. Performance-based seismic engineering of low and medium-rise steel frames

    … response parameters such as, interstory drift, ductility demand, and dissipated hysteretic energy are obtained. In addition, a modified form of Park-Ang damage index is calculated for moment-resisting frames. The seismic performance of the steel frames is assessed in accordance with the …

    njit Repository record for Performance-based seismic engineering of low and medium-rise steel frames (opens in a new tab)

  15. Modified substitute structure method for analysis of existing R/C structures

    … modified substitute structure method computes ductility demand of each member via an elastic modal analysis, in which reduced flexural stiffness and substitute damping factors are used iteratively. As a result of the analysis, it is possible to describe, in general terms, the location and …

    ubc Repository record for Modified substitute structure method for analysis of existing R/C structures (opens in a new tab) Download PDF for Modified substitute structure method for analysis of existing R/C structures (opens in a new tab)

  16. Connections to concrete-filled steel tubes

    … studied, and the connections with the highest ductility demand were isolated. The second phase of the research was devoted to the inelastic finite element analysis of several connection details. A 3-D finite element model was developed for each connection detail. The parameters used in the …

    uiuc Repository record for Connections to concrete-filled steel tubes (opens in a new tab)

  17. Effect of Viscous Fluid Dampers on Steel Moment Frame Designed for Strength and Hybrid Steel Moment Frame Design

    … for low intensity gentle earthquakes. The ductility demand IDA study proves that as the frames become more hybrid, the ductility demand increases for the special detailing frame, where plastic capacity was reduced, and decreases for the ordinary detailing frame, where the plastic capacity …

    vt Repository record for Effect of Viscous Fluid Dampers on Steel Moment Frame Designed for Strength and Hybrid Steel Moment Frame Design (opens in a new tab)

  18. Effect of retrofit strategies on mitigating progressive collapse of multistorey steel frame structures

    … (the chord rotation, tie forces and displacement ductility demand), 2) investigate the effect of variation of bay span on the three performance parameters by studying three models of different spans of 5.0, 7.5 and 9.0 m subjected to GSA load, and 3) propose equations for predicting the effect of …

    concordia Download PDF for Effect of retrofit strategies on mitigating progressive collapse of multistorey steel frame structures (opens in a new tab)

  19. Quasi-static cyclic loading protocol development for the seismic performance assessment of bridge piers

    … need to be representative of the seismic demands to which a structural component may be subjected during seismic events. A standard loading protocol available in the literature will not necessarily yield a meaningful response. For the quasi-static cyclic test program, a loading protocol …

    ubc Repository record for Quasi-static cyclic loading protocol development for the seismic performance assessment of bridge piers (opens in a new tab) Download PDF for Quasi-static cyclic loading protocol development for the seismic performance assessment of bridge piers (opens in a new tab)

Page 1 of 3