Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 100 for “"Duty ratio"”

  1. Large signal transient analysis of duty ratio controlled DC-to-DC converter

    The large-signal transient response of duty ratio controlled dc-to-dc converters is investigated using the phase-plane technique. The transition pattern of large-signal trajectories is provided in terms of the circuit parameter and operating conditions. Several transient trajectories of practical …

    vt Repository record for Large signal transient analysis of duty ratio controlled DC-to-DC converter (opens in a new tab)

  2. Torque Ripple Minimization in Direct Torque Control of Induction Machines

    … drive performance can be achieved by varying the duty ratio of the selected voltage vector during each switching period according to the magnitude of the torque error and position of the stator flux. A duty ratio control scheme for an inverter-fed induction machine using DTC method is presented in …

    ohiolink Repository record for Torque Ripple Minimization in Direct Torque Control of Induction Machines (opens in a new tab)

  3. Solution Kinetic Study Of Vesicle Trafficking Of Zymogen Granules And Myosin 16a Molecular Motor

    … move in actin tracks continuously and have high duty ratio. For e.g. myosin 5a transports neuronal vesicles (diameter: 40 nm) and has high duty ratio. The high duty ratio motors bound to actin more than half of the ATPase cycle. In contrast, myosin 1c and myosin 5c are low duty ratio motors and …

    wayne-thes Repository record for Solution Kinetic Study Of Vesicle Trafficking Of Zymogen Granules And Myosin 16a Molecular Motor (opens in a new tab)

  4. Study Of Zyomogen Granule Movement Along Actin Filaments Using A Single Beam Optical Trap

    … motors have certain characteristics, a high duty ratio and the ability to move continuously along actin tracks. The high duty ratio means that during most of the ATPase cycle the motor is in a bound state with actin. Interestingly, Myosin 1c and 5c are low duty ratio motors, meaning that the …

    wayne-thes Repository record for Study Of Zyomogen Granule Movement Along Actin Filaments Using A Single Beam Optical Trap (opens in a new tab)

  5. Hypertrophic cardiomyopathy-linked alpha-cardiac actin mutations and their role on actomyosin interactions

    … actin and myosin result in contraction. The duty ratio, r, is the fraction of time spent by actin and myosin interacting. My hypothesis is that mutations in subdomain 1 of actin increase the duty ratio allowing for HCM development. The duty ratio for the R95C ACTC variant was found to be …

    guelph Repository record for Hypertrophic cardiomyopathy-linked alpha-cardiac actin mutations and their role on actomyosin interactions (opens in a new tab)

  6. AI-enhanced high-frequency, high-efficiency multi-input single-output converter for offshore photovoltaic systems

    Offshore photovoltaic generation provides an attractive pathway for expanding solar-energy deployment without directly competing with valuable land resources. However, offshore and floating platforms experience rapid irradiance variation, partial shading, wave-induced motion, nonuniform cooling, …

    nanyang Repository record for AI-enhanced high-frequency, high-efficiency multi-input single-output converter for offshore photovoltaic systems (opens in a new tab)

  7. Design and development of a high-gain power converter based on active-switched inductor-capacitor and voltage multiplier

    … high-gain converters often use extreme duty ratios, transformers, coupled inductors, multiple active switches, or cascaded voltage multipliers, increasing converter size, cost, complexity, semiconductor stress, and power loss. For microinverter and renewable energy applications, this …

    qu-belfast Repository record for Design and development of a high-gain power converter based on active-switched inductor-capacitor and voltage multiplier (opens in a new tab) Embargoed until 2028-12-31

  8. Improvements in direct torque control of induction motors

    … both the torque and the flux. Therefore, a duty ratio has to be determined each switching time. By means of varying the duty ratio between its extreme values (0 up to 1) it is possible to apply any voltage to the motor. The optimum duty ratio per sampling period is a non-linear function of …

    barcelona Repository record for Improvements in direct torque control of induction motors (opens in a new tab)

  9. Development of an Intelligent Electrolytic In-process Dressing (ELID) grinding system

    … over dressing. In conventional ELID grinding the duty ratio of the dressing power supply is kept constant throughout the grinding cycle. However this method is not suitable to achieve grinding wheel truing which is very important to maintain the stability of the grinding. In this research work a …

    nus Repository record for Development of an Intelligent Electrolytic In-process Dressing (ELID) grinding system (opens in a new tab)

  10. Analysis and design of a 500 kHz series resonant inverter for induction heating applications

    … the power stage components, and to predict the duty ratio and the operating frequency range is presented using a PSC-SRl design example operating at 500 kHz and 10 kW. In addition, a novel and simple frequency control circuit that implements the proposed frequency control strategy is provided. …

    vt Repository record for Analysis and design of a 500 kHz series resonant inverter for induction heating applications (opens in a new tab)

  11. Modeling, Analysis and Experimental Implementation of the Parallel Power Processing Topology for Solar PV Applications

    … the response of the system for any change in the duty ratio. The simulation and experimental results confirmed the validity of the model and the high efficiency system operation with MPP tracking.</p><p>The use of the PPP with the split loads is also presented along with the simulation results. …

    ohiolink Repository record for Modeling, Analysis and Experimental Implementation of the Parallel Power Processing Topology for Solar PV Applications (opens in a new tab)

  12. Switch mode emulation of large value capacitors in the rotor circuit to improve the induction motor performance.

    … an enhancement of the motor performance. The duty ratio and its resolution are dependent on the rotor circuit parameters that vary with the motor load. Fuzzy control for the duty ratio to achieve the required phase angle is investigated. Verification is presented by experimentation in a …

    nott-trent Repository record for Switch mode emulation of large value capacitors in the rotor circuit to improve the induction motor performance. (opens in a new tab)

  13. The modelling of quasi-resonant and multi-resonant boost converters

    … function, which can be seen as the equivalent duty ratio of the converter, and its analytic expression is determined. Multi-resonant converters have two characteristic functions and a numerical method is developed to evaluate them. The dc (steady-state) model of quasi-resonant and …

    nott-trent Repository record for The modelling of quasi-resonant and multi-resonant boost converters (opens in a new tab)

  14. Direct torque control of three-level inverter fed IPMSM drive

    … beginning of this thesis reveal that the integration of three-level inverters into switching table based DTC drives is complicated and does not readily alleviate the shortcomings of classical DTC. Firstly, 3L-DTC drives are typically intended for use in higher power motors and therefore, the …

    nanyang Repository record for Direct torque control of three-level inverter fed IPMSM drive (opens in a new tab)

  15. Design of an IGBT-Based Pulsed Power Supply for Non-continuous-mode Electrospinning

    … their small size, high surface-to-volume ratio, high porosity, and superior mechanical performance. Recently, controlled drug delivery systems have gained significant attention, especially with respect to the use of polymer nanofibres. For these systems, the ability to control of the …

    waterloo Repository record for Design of an IGBT-Based Pulsed Power Supply for Non-continuous-mode Electrospinning (opens in a new tab)

  16. Numerical and Experimental Investigation of Parabola-Cone Structured Films on Perovskite Solar Cells

    … parameters such as height, base diameter, aspect ratio, angle of incidence and base duty ratio. The modelling results suggest that the aspect ratio and the base duty ratio of parabola-cone array are two key parameters that can affect the transmission and absorption of incident light. It was …

    auckland-ms Repository record for Numerical and Experimental Investigation of Parabola-Cone Structured Films on Perovskite Solar Cells (opens in a new tab)

  17. THE APPLICATION OF PULSE MODULATED PLASMA TO THE PLASMA ENHANCED CHEMICAL VAPOR DEPOSITION OF DIELECTRIC MATERIALS

    … not affect any other qualities; the O2/precursor ratio is the most influential factor among all variables considered in this experiment. the deposition hardness and O: Si ratio always increase with this ratio while the carbon content always decreases . However, different precursors require …

    ohiolink Repository record for THE APPLICATION OF PULSE MODULATED PLASMA TO THE PLASMA ENHANCED CHEMICAL VAPOR DEPOSITION OF DIELECTRIC MATERIALS (opens in a new tab)

  18. How do regulated thin filaments with hypertrophic cardiomyopathy-linked α-cardiac actin affect actomyosin interactions?

    … and biophysical assays to calculate the duty ratio (r). Compared to human ACTC (WTrec), E99K, R95C, F90Δ, and H88Y yielded higher, lower, or similar r. The varying r suggested that actomyosin changes may occur at the level of regulation by troponin and tropomyosin. Compared to WTrec …

    guelph Repository record for How do regulated thin filaments with hypertrophic cardiomyopathy-linked α-cardiac actin affect actomyosin interactions? (opens in a new tab)

  19. A soft-switch back-to-back bi-directional DC-DC converter and the FPGA based digital control design

    … bi-directional converter is operated with fixed duty ratio and phase shift control. Through analysis, a simple fist-order system is obtained for the converter. Using a digital PI controller, the close loop system achieves a satisfactory dynamic performance in both step-down and step-up mode …

    nus Repository record for A soft-switch back-to-back bi-directional DC-DC converter and the FPGA based digital control design (opens in a new tab)

  20. High-performance digital control of UPS inverters

    … Both these methods can achieve a wide range of duty ratio, independent of the model of inverter.

    nus Repository record for High-performance digital control of UPS inverters (opens in a new tab)

Page 1 of 5