Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 1,118 for “"Duty-cycle"”

  1. Duty cycle control in wireless sensor networks

    … this thesis study, basic routing algorithms and duty cycle control algorithms for WSNs in the literature are studied. One of the duty cycle control algorithms, Role Alternating, Coverage Preserving, and Coordinated Sleep algorithm (RACP) is examined and simulated using the ns2 simulation …

    metu Repository record for Duty cycle control in wireless sensor networks (opens in a new tab)

  2. Transistorized variable duty cycle D.C. voltage regulator

    … factors Influencing the efficiency of a variable duty cycle transistorised regulator designed to meet these specifications. Basic to the theoretical efficiency of this type of regulator is the relation: duty cycle = conduction time/total period where "conduction time" is the interval during which …

    nps Repository record for Transistorized variable duty cycle D.C. voltage regulator (opens in a new tab)

  3. Duty cycle analysis for aircraft control surface actuation

    … PBW actuators can benefit significantly from a duty cycle based requirements specification. Two particularly areas of concern, which have been noted in literature, include PBW actuator thermal performance and durability, both of which are directly influenced by the duty cycle. A particularly …

    texas Repository record for Duty cycle analysis for aircraft control surface actuation (opens in a new tab) Restricted access

  4. Duty cycle and luminance considerations in multi-flash campimetry

    concordia

  5. Sleipnir: a versatile extremely low duty-cycle sensor network.

    … we then have to build extremely low duty-cycle sensor networks where during the operation of sensor applications, sensor nodes activate very briefly and stay in a dormant state for a very long period of time. In this dissertation research, we initiate the first systematic research for …

    umn Repository record for Sleipnir: a versatile extremely low duty-cycle sensor network. (opens in a new tab)

  6. Operational Analysis of a CLLC Converter with Duty Cycle Control

    Renewable energy sources generate electricity at different magnitudes and in various forms, such as AC to DC sources. To consume this energy, society utilizes power electronics to convert this electrical energy into a form that can be utilized by a standard load. There are a variety of approaches …

    ohiolink Repository record for Operational Analysis of a CLLC Converter with Duty Cycle Control (opens in a new tab)

  7. FRAM based low power systems for low duty cycle applications

    Ferro-Electric Random Access Memory (FRAM) is a leap forward in non-volatile data storage technology for embedded systems. It allows for persistent storage without any power consumption, fulfilling the same role as flash memory. FRAM, however, provides several major advantages over flash memory, …

    alaska Repository record for FRAM based low power systems for low duty cycle applications (opens in a new tab)

  8. HIGH DUTY CYCLE ECHOLOCATION AND PREY DETECTION ABILITY IN BATS

    … bats separate pulse and echo in time (low duty cycle bats), a few species separate pulse and echo in frequency (high duty cycle). The type of écholocation is defined by the pattern of signal emission, but many other call variables differ significantly between the two approaches. This study …

    uwo Repository record for HIGH DUTY CYCLE ECHOLOCATION AND PREY DETECTION ABILITY IN BATS (opens in a new tab)

  9. IMPACT OF GRATING DUTY-CYCLE RANDOMNESS ON DFB LASER PERFORMANCE

    The duty-cycle randomness (DCR) lying the Bragg grating of the distributed feedback (DFB) lasers introduced by the fabrication process is inevitable even with the state-of-the-art technologies such as the electron beam lithography and dry or wet etching. This thesis investigates the impact of …

    mcmaster Repository record for IMPACT OF GRATING DUTY-CYCLE RANDOMNESS ON DFB LASER PERFORMANCE (opens in a new tab)

  10. RF transmitter using 33% duty cycle LO signal for harmonic suppression

    … is demonstrated in previous literature. The 33% duty cycle LO scheme is used since it intrinsically does not have 3rd-order harmonic. Thus the intermodulation with 3×LO (3LO) frequency component is avoided. As a result, CIM3 is suppressed at the RF output. This technique is not sensitive to …

    nanyang Repository record for RF transmitter using 33% duty cycle LO signal for harmonic suppression (opens in a new tab)

  11. Duty-Cycle Based Physical Unclonable Functions (PUFs) for Hardware Security Applications

    Duty cycle and frequency are important characteristics of periodic signals that are exploited to develop a variety of application circuits in IC design. Controlling the duty cycle and frequency provides a method to develop adaptable circuits for a variety of applications. These applications range …

    usf Repository record for Duty-Cycle Based Physical Unclonable Functions (PUFs) for Hardware Security Applications (opens in a new tab)

  12. A Temperature Aware Asynchoronous Duty Cycle Protocol in Wireless Body Area Networks

    … in routing to prevent heat rise and efficient duty cycle protocols to conserve battery life, to the best of our knowledge none of them address both the issues. In our proposed protocol we adopt the shortest hop routing of packets from one sensor node to another sensor node. We also establish an …

    ohiolink Repository record for A Temperature Aware Asynchoronous Duty Cycle Protocol in Wireless Body Area Networks (opens in a new tab)

  13. The Characterization and Feasibility of a Low-Duty-Cycle Diaphragmless Shock Tube

    … gas pressures repeatedly to within 0.31% at low-duty-cycle of 6 seconds. The driven gas pressure profiles within the test-section suggest that shock waves may be forming within test section for a driver gas pressure of 200 psig and above, which corresponds to shock wave Mach numbers of 1.7 to …

    tamu Repository record for The Characterization and Feasibility of a Low-Duty-Cycle Diaphragmless Shock Tube (opens in a new tab)

  14. Measurement and design on data collection of low-duty cycle wireless sensor networks

    … energy-constrained sensor nodes, are mostly duty-cycled and rely on multi-hop routing to collect data. Data collection mechanism is thus a building block of WSN systems. The performance of low duty cycle WSN nowadays, however, are far restricted by the limited understanding and the …

    hkust Repository record for Measurement and design on data collection of low-duty cycle wireless sensor networks (opens in a new tab)

  15. Efficient duty cycle MAC protocols for dynamic traffic loads in wireless sensor networks

    … and many protocols have been proposed based on duty cycling to reduce this cost. These protocols, either synchronous or asynchronous, are mainly optimized for light traffic loads. A WSN, however, could often experience bursty and high traffic loads, as may happen for example with broadcast or …

    rice Repository record for Efficient duty cycle MAC protocols for dynamic traffic loads in wireless sensor networks (opens in a new tab)

  16. The Effect of Handgrip Exercise Duty Cycle on Brachial Artery Flow Mediated Dilation

    … function). However, different exercise duty-cycles (ratio of handgrip relaxation to contraction in seconds) produce different patterns of BA shear stress with different anterograde and retrograde flow magnitudes. PURPOSE: To determine the impact of HGEX duty-cycle on BA %FMD while …

    queens Repository record for The Effect of Handgrip Exercise Duty Cycle on Brachial Artery Flow Mediated Dilation (opens in a new tab)

  17. A variable duty cycle maximum power point tracking algorithm for wind energy conversion systems.

    … limitations. This algorithm employs a variable duty cycle to reduce the oscillations in delivered power once the peak power is detected. The performance of the proposed algorithm was evaluated using MA TLAB-SIMULINK. Efficiencies of 95.48%, 98.8%, and 92.2% were observed under constant wind …

    louisville Repository record for A variable duty cycle maximum power point tracking algorithm for wind energy conversion systems. (opens in a new tab)

Page 1 of 56