Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 35 for “"Dynabeads"”.

  1. PHYSICO-CHEMICAL STUDIES OF THE VESICULAR GLUTAMATE TRANSPORTER 1 (VGLUT1)

    … a nickel chelating column or cobalt-coated Dynabeads. The HiTrapTM nickel chelating column proved to be more efficient in purification of recombinant VGLUT1 than Dynabeads. To study the physico-chemical properties and structure of VGLUT1 and advance our understanding of the membrane …

    montana Repository record for PHYSICO-CHEMICAL STUDIES OF THE VESICULAR GLUTAMATE TRANSPORTER 1 (VGLUT1) (opens in a new tab)

  2. PHYSICO-CHEMICAL STUDIES OF THE VESICULAR GLUTAMATE TRANSPORTER 1 (VGLUT1)

    … a nickel chelating column or cobalt-coated Dynabeads. The HiTrapTM nickel chelating column proved to be more efficient in purification of recombinant VGLUT1 than Dynabeads. To study the physico-chemical properties and structure of VGLUT1 and advance our understanding of the membrane …

    montana-tech Repository record for PHYSICO-CHEMICAL STUDIES OF THE VESICULAR GLUTAMATE TRANSPORTER 1 (VGLUT1) (opens in a new tab)

  3. APPLICATION OF NANOTECHNOLOGY TO PATHOGEN DETECTION AND INACTIVATION

    … IMS were 1.4~26 times higher than those of Dynabeads®-based IMS. When combined with RT-PCR, IMNP-based method, with a detection limit of 226 CFU/0.5 ml milk, was ca. 3 log magnitude more sensitive than Dynabeads®-based method. Cell numbers derived from IMNP-based RT-PCR were more than 25 …

    clemson Repository record for APPLICATION OF NANOTECHNOLOGY TO PATHOGEN DETECTION AND INACTIVATION (opens in a new tab)

  4. Proof-of-Concept of a Jagged1-functionalized PEG-4MAL Hydrogel

    … strategy in which JAG1 is immobilized on dynabeads and delivered in a 4-arm poly(ethylene glycol) maleimide (PEG-4MAL) hydrogel. Despite success in inducing osteogenic differentiation and bone formation, the lack of FDA approval for dynabeads is an obstacle for translation that motivates …

    gatech Repository record for Proof-of-Concept of a Jagged1-functionalized PEG-4MAL Hydrogel (opens in a new tab)

  5. Qualitative und quantitative Bestimmung von Nukleinsäuren humaner pathogener Viren in der Umwelt als Instrument der Risikoabschätzung

    … der paramagnetischen Polystyrolkugeln der Sorte Dynabeads untersucht und optimiert. Betrachtet werden die untersuchten Standartbedingungen am Beispiel des Enterovirus Poliovirus Sabin 1 in Bezug auf die Effizienz des direkten bzw. indirekten Einfangs, des Lysevermögens der intakten Viren, sowie …

    fu-berlin Repository record for Qualitative und quantitative Bestimmung von Nukleinsäuren humaner pathogener Viren in der Umwelt als Instrument der Risikoabschätzung (opens in a new tab)

  6. \(In\) \(vitro\)-Aktivierung muriner regulatorischer T-Zellen durch die Anwendung des CD28-Superagonisten D665

    … murine Tregs in dieser Arbeit im Vergleich zur Dynabeads-basierten Stimulationsmethoden eine nicht signifikant stärkere Expansion in Folge der in vitro-Kultivierung auf, ohne Einfluss auf den typischen Phänotyp der Tregs zu nehmen. Zudem zeichneten sich CD28-SA-stimulierte Tregs durch eine nicht …

    wurz-thes Repository record for \(In\) \(vitro\)-Aktivierung muriner regulatorischer T-Zellen durch die Anwendung des CD28-Superagonisten D665 (opens in a new tab)

  7. Využití magnetických mikročástic pro izolaci DNA

    … byly použity komerční magnetické mikročástice Dynabeads® DNA DIRECT™ Universal (Dynal, Norsko) na bázi polystyrenu a částice MPG® Uncoated (PureBiotech, USA) na bázi magnetického skla. Sledována byla závislost množství izolované DNA na výchozí koncentraci DNA v roztoku a závislost množství …

    brno-tech Repository record for Využití magnetických mikročástic pro izolaci DNA (opens in a new tab)

  8. Rare-earth elements recovery from fluorescent lamp phosphors: carrier magnetic separation with biotechnologically functionalized carriers

    … darunter kommerziell erhältliche Hochleistungs-Dynabeads sowie synthetisierte Eisenoxid- und Kern-Schale-Nanopartikel, wurden funktionalisiert und charakterisiert. Im Rahmen der Forschungsgruppe BioKollekt lag ein besonderer Fokus auf dem Potenzial der Peptidfunktionalisierung zur Erzeugung …

    qucosa-diss

  9. Entwicklung und Evaluierung neuer Methoden zur Analyse des Proteoms von Listeria monocytogenes in infizierten Wirtszellen

    … mit unterschiedlicher Beschichtung gewählt: Dynabeads anti Listeria (Dynal, Oslo), Kieselgel  Magnetit Beads (MERCK in Entwicklung), Dynabeads M-270 Epoxy – CBD Beads (Beschichtung mit Phagenlysin Ply 118). Hierbei konnte nur für die Kieselgel + Magnetit Beads eine hinreichende …

    wurz-thes Repository record for Entwicklung und Evaluierung neuer Methoden zur Analyse des Proteoms von Listeria monocytogenes in infizierten Wirtszellen (opens in a new tab)

  10. Surface Directed Monoclonal Antibodies against STEC Aid in the Reduction of Pathogen Detection Times from Food and Water

    … using specific monoclonal antibody (mAb)-coated Dynabeads, and detection via fluorescence microscopy, (2) the addition of enrichment culture into a flow through system consisting of a column packed with large polystyrene beads (≥ 100 μm) coated with specific mAbs for capture. The results indicate …

    ottawa-retro Repository record for Surface Directed Monoclonal Antibodies against STEC Aid in the Reduction of Pathogen Detection Times from Food and Water (opens in a new tab)

  11. Optimization of automated immunomagnetic separation for the detection of escherichia coli 0157: H7 by quantitative polymerase chain reaction

    … with specific, antibody coated, MyOneTm Dynabeads®. The new protocol was found to increase capture by approximately 60 % in comparison to the standard AIMS protocol for Escherichia coil. The improved protocol was used to test spiked food samples according to the BS EN ISO 16140:2003 …

    cent-lancashire Download PDF for Optimization of automated immunomagnetic separation for the detection of escherichia coli 0157: H7 by quantitative polymerase chain reaction (opens in a new tab)

  12. Two-dimensional assembly of colloidal particles: fabrication and application

    … yeast cells and magnetic particles, e.g., the Dynabeads, under a perpendicularly applied AC electric field due to included dipolar attraction. Interestingly, the hybrid clusters can propel under the same electric field due to unbalanced electrohydrodynamic flow surrounding them. To remotely …

    colo-mines Repository record for Two-dimensional assembly of colloidal particles: fabrication and application (opens in a new tab)

  13. A Novel and Rapid Staphylococcus aureus Bacterial Identification Method Utilizing ImmunoMagnetic Beads and Single Cell Laser-Light Scattering

    … that anti-Protein A conjugated to magnetic DynaBeads could bind to surface Protein A on S. aureus from swab sample and facilitate their isolation upon exposure to a magnetic field within a 4-8 hour procedure. S. aureus cells isolated by IMS would then be accurately identified using …

    nmu Repository record for A Novel and Rapid Staphylococcus aureus Bacterial Identification Method Utilizing ImmunoMagnetic Beads and Single Cell Laser-Light Scattering (opens in a new tab)

  14. Methodological Improvements in the mRNA Profiling Assays for Incorporation into DNA Casework Workflows

    … It involves extraction of RNA using the Dynabeads™ mRNA DIRECT™ Kit, while saving the extraction waste fractions for downstream male-DNA quantitation and STR profiling. The RNA is then used in a rapid and sensitive 1-step combined reverse transcription-HRM assay to positively detect the …

    ucf Repository record for Methodological Improvements in the mRNA Profiling Assays for Incorporation into DNA Casework Workflows (opens in a new tab)

  15. Zum Nachweis von pathogenen Prionen mittels "Kapillarelektrophorese-laserinduzierter Fluoreszenz (CE-LIF)"

    … Eine selektive Bindung von PrPsc an Dynabeads® gekoppeltem Plasminogen konnte nicht nachgewiesen werden. Dagegen wurde eine Anlagerung an Antikörper-beschichteten Beads festgestellt. Allerdings war die Bin-dungskapazität der Beads bei Versuchen in mit in PBS gelöstem PrPc oder PrPsc …

    lmu-germany Repository record for Zum Nachweis von pathogenen Prionen mittels "Kapillarelektrophorese-laserinduzierter Fluoreszenz (CE-LIF)" (opens in a new tab)

  16. Microfluidic cancer cell isolation system using magnetic nanoparticle hybrids and advanced interdigitated electrode technology

    … a successful commercial product is Invitrogen’s Dynabeads® Technology. Magnetic cell isolation technologies have been evolving slowly mainly due to the complexity of the cancers, the short number of successful cancer biomarkers, and the ethics of magnetic nanoparticles in in-vivo cancer therapy. …

    whiterose Download PDF for Microfluidic cancer cell isolation system using magnetic nanoparticle hybrids and advanced interdigitated electrode technology (opens in a new tab)

  17. Etablierung eines Protokolls zur Transfektion von porcinen T-Zellen als Vorarbeit für zukünftige Großtiermodelle in der Immunologie

    … T-Zellen mittels Antikörper-beschichteten Dynabeads und Anti-CD28 mAb 3D11 zeigt eine Zellexpansion mit Zunahme der Viabilität im Verlauf. Die Integration der Transfektion in den Expansionsprozess ermöglicht die Proliferation der T-Zellen nach der Transfektion. Zukünftige Forschungsarbeiten …

    wurz-thes Repository record for Etablierung eines Protokolls zur Transfektion von porcinen T-Zellen als Vorarbeit für zukünftige Großtiermodelle in der Immunologie (opens in a new tab)

  18. Optimizing a potency assay for regulatory T cell therapies

    … proliferation was activation for 3 days with Dynabeads Human T-Expander CD3/CD28. Human serum supplementation in serum-free media was necessary for Treg suppression. Measuring suppression of T cell proliferation alone was poorly able to distinguish between suppression mediated by activated …

    ubc Repository record for Optimizing a potency assay for regulatory T cell therapies (opens in a new tab) Download PDF for Optimizing a potency assay for regulatory T cell therapies (opens in a new tab)

  19. Characterisation of the myeloid compartment in ovarian cancer

    … capability, which led to phagocytosis of the Dynabeads thus affecting their ability to cause T cell proliferation and demonstrating an inaccurate immunosuppressive effect. Further suppression analyses demonstrated a lack of consistent immunosuppression and as such their phenotypic …

    birmingham Download PDF for Characterisation of the myeloid compartment in ovarian cancer (opens in a new tab)

  20. Analyzing CD8+ Cytotoxic T Lymphocyte Migration in The Complex Pancreatic Ductal Adenocarcinoma Tumor Microenvironment

    … tumor-bearing KPC/KPCT mice and activated using Dynabeads T cell activator. Fully activated CD8+ can then be seeded on top of the tumor slice, and attached/infiltrated T cell migration can be monitored using time-lapse imaging utilizing multiphoton laser scanning microscope (MPLSP), and tumor …

    umn Repository record for Analyzing CD8+ Cytotoxic T Lymphocyte Migration in The Complex Pancreatic Ductal Adenocarcinoma Tumor Microenvironment (opens in a new tab)

Page 1 of 2