Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"Dynamic Impedance"”.

  1. MEMS Coulter counter for dynamic impedance measurement of time sensitive cells

    … characterized, which can detect and monitor the dynamic cell impedance changes in situ as a function of time and cellular volumetric changes after mixing isolated cell populations with different extracellular media within 0.2 second from the start of mixing. The novelty of this design is the use …

    missouri Repository record for MEMS Coulter counter for dynamic impedance measurement of time sensitive cells (opens in a new tab)

  2. Dynamic impedance studies of oxidation of nickel and glycerol at nickel electrodes.

    This thesis uses dynamic electrochemical impedance spectroscopy (dEIS) to study how nickel undergoes electrooxidation. An electropolishing step is used to make a clean surface, and then the transformation of nickel to α-Ni(OH)2 is studied, including how a holding potential affects the double layer …

    uvic Repository record for Dynamic impedance studies of oxidation of nickel and glycerol at nickel electrodes. (opens in a new tab)

  3. Computational Model of Electroconvulsive Therapy Considering Electric Field Dependent Skin Conductivity

    … with those of the patient’s head, determine the impedances measured by the device and govern current delivery to the brain and ECT outcomes. However, the precise relations among physical properties of the stimulus, patient head anatomy, and patient-specific impedance to the passage of current are …

    cuny Repository record for Computational Model of Electroconvulsive Therapy Considering Electric Field Dependent Skin Conductivity (opens in a new tab)

  4. Backcalculation and Sensitivity of Non-Destructive Tests to Temperature Variations in Flexible Pavements

    … structures does not take into account the dynamic nature of tests. Another limitation of the elastostatic approach is that it gives only one piece of information from each loaddeflection history recorded by a geophone. The number of unknowns typically exceeds two (at least pavement and …

    mcmaster Repository record for Backcalculation and Sensitivity of Non-Destructive Tests to Temperature Variations in Flexible Pavements (opens in a new tab)

  5. Dynamic impedances of soil layers and piles

    … in this dissertation are: (1) to evaluate the dynamic impedance of horizontally inhomogeneous, thin soil layers and of piles embedded in such layers; and (2) to provide improved insight into the response of vertically excited piles bearing on a stratum of arbitrary stiffness. The dissertation …

    rice Repository record for Dynamic impedances of soil layers and piles (opens in a new tab)

  6. Parametric average value modeling of PWM DC-DC converters

    … in terms of duty cycle and the switching-cell dynamic-impedance. An automated small-signal characterization method using a general purpose simulator is also proposed. The resulting parametric average value model is compared with the hardware prototype, the detailed simulation and the …

    ubc Repository record for Parametric average value modeling of PWM DC-DC converters (opens in a new tab) Download PDF for Parametric average value modeling of PWM DC-DC converters (opens in a new tab)

  7. Development of 3D Printed and 3D Metal-Based Micro/Nanofabricated, and Nano-Functionalized, Microelectrode Array (MEA) Biosensors For Flexible, Conformable, and In Vitro Applications

    … thesis focuses on two developmental tracks: "Dynamic 3D MEAs" and metal microfabrication for 3D MEAs. In the first part of the thesis, we explore the capabilities and limitations of 3D printed microserpentines (µserpentines) and utilize these structures to develop dynamic 3D microelectrodes. …

    ucf Repository record for Development of 3D Printed and 3D Metal-Based Micro/Nanofabricated, and Nano-Functionalized, Microelectrode Array (MEA) Biosensors For Flexible, Conformable, and In Vitro Applications (opens in a new tab)

  8. Small-signal analysis and design of a distributed power system

    … concern is the effect of the second stage's dynamic impedance on the first stage's control loops. It is found that the negative dynamic resistance of the second stage gives rise to right-half-plane poles in the opened-loop gains of the first stage. Fundamental loop-gain analysis is used to …

    vt Repository record for Small-signal analysis and design of a distributed power system (opens in a new tab)

  9. A Comprehensive Study Of Excimer Laser Systems

    … digitized and used to find such parameters as dynamic impedance of the load, energy deposited in the gas, and peak power during the pulse. The effects of varying the length and impedance of the cable PFN were studied. Several interesting relationships were discovered between the various …

    unm Repository record for A Comprehensive Study Of Excimer Laser Systems (opens in a new tab)

  10. Design of Power Receiving Units for 6.78MHz Wireless Power Transfer Systems

    … loss. The inherent feedback from the power stage dynamics to the sensed signal is analyzed to design stable and robust synchronization control, even at a low power of 0.02 W. The control system is accomplished using commercial components, including a low-cost microcontroller, which eliminates the …

    ut-knoxville Repository record for Design of Power Receiving Units for 6.78MHz Wireless Power Transfer Systems (opens in a new tab)

  11. Theory and Experiment of Antimony-Based Type-Ii Superlattice Infrared Photodetectors

    … with promising room temperature performance (dynamic impedance and area product (R0A) equals to 22 Ocm2 at 300 K) are obtained, a new design for interband tunneling detectors is introduced. With a thicker active region, the QE of interband tunneling detectors is improved more than five times …

    uiuc Repository record for Theory and Experiment of Antimony-Based Type-Ii Superlattice Infrared Photodetectors (opens in a new tab)

  12. ADVANCED SYNCHRONOUS MACHINE MODELING

    … systems, which makes direct use of the natural dynamic impedance of the rectifier without introducing low-frequency approximations or algebraic loops. By using this formulation, a direct interface of the AVM is achieved with inductive circuitry on both the ac and dc sides allowing traditional …

    uky-thes Repository record for ADVANCED SYNCHRONOUS MACHINE MODELING (opens in a new tab)

  13. Design, Testing, and Analysis of Advanced Massive MIMO Transmitters

    … PA performance is highly sensitive to load impedance. While isolators in 4G systems maintain a constant 50 Ω load, their use in massive MIMO arrays is impractical due to cost, size, bandwidth, and integration constraints. Consequently, antenna mismatches and mutual coupling introduce dynamic …

    waterloo Repository record for Design, Testing, and Analysis of Advanced Massive MIMO Transmitters (opens in a new tab)

  14. A Multi-Pronged, Noninvasive Probing of Electrodeposition in Li-Ion Batteries

    … by the development and utilization of a novel dynamic impedance measurement technique. The impedance response of the cell is captured across different states of charge of normally charged cells and of cells where electrodeposition was proven to occur. Through trends in the impedance data, and …

    tamu Repository record for A Multi-Pronged, Noninvasive Probing of Electrodeposition in Li-Ion Batteries (opens in a new tab)

  15. Non-linear dynamic analysis of shallow foundations

    Footings subjected to dynamic loads are commonly designed under the simplifying assumption of linear or equivalent-linear viscoelastic soil behaviour. Even though this approach is simple to implement and, in some cases, could take advantage of available closed-form solutions, the outcomes remain a …

    bristol Repository record for Non-linear dynamic analysis of shallow foundations (opens in a new tab) Download PDF for Non-linear dynamic analysis of shallow foundations (opens in a new tab)

  16. Technical and Economic Integration of Voltage Source Converter Based High Voltage Direct Current Transmission in Power Systems

    … is proposed for power system small signal dynamic performance improvement by use of an embedded voltage source converter (VSC) based high voltage direct current (HVDC) system. Embedded HVDC refers to a meshed AC grid with all HVDC terminals connected within the same AC grid. The concept of …

    tamu Repository record for Technical and Economic Integration of Voltage Source Converter Based High Voltage Direct Current Transmission in Power Systems (opens in a new tab)

  17. Control de la temperatura en sistemas de calentamiento por microondas

    … valuable data can be obtained for the process dynamics when using microwave technology. With this objective in mind, in a first step different suitable types of microwave applicators have been studied, as well as several optimization techniques for the temperature distribution within the …

    upv Repository record for Control de la temperatura en sistemas de calentamiento por microondas (opens in a new tab)

  18. ANALYSIS AND DESIGN OF BODY-COUPLED POWERING TX FOR BODY AREA NETWORK APPLICATIONS

    … the capacitive body-coupled powering with de-Q impedance booster and interface impedance matching technique, is proposed and demonstrated to sustain all wearable devices around human body with full body area coverage. To improve the power recovery and system efficiency, the proposed dynamic …

    nus Repository record for ANALYSIS AND DESIGN OF BODY-COUPLED POWERING TX FOR BODY AREA NETWORK APPLICATIONS (opens in a new tab) Download file for ANALYSIS AND DESIGN OF BODY-COUPLED POWERING TX FOR BODY AREA NETWORK APPLICATIONS (opens in a new tab)

  19. Understanding and monitoring the dynamic process of bipolar tissue hemostasis process

    … with experimental results. An existing minimal impedance-based monitoring method was evaluated under both the general tissue hemostasis process and the large diameter vessel sealing process. It was found that the minimal impedance-based monitoring method performed poorly with both muscle tissue …

    texas Repository record for Understanding and monitoring the dynamic process of bipolar tissue hemostasis process (opens in a new tab)

Page 1 of 2