Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 5 of 5 for “"Dynamic range extension"”

  1. High Frequency (HF) radio signal amplitude characteristics, HF receiver site performance criteria, and expanding the dynamic range of HF digital new energy receivers by strong signal elimination

    … digital technology does not provide enough dynamic range, sensitivity, or sampling rate. Alternative dynamic range extension methods are examined. A new method of dynamic range extension by removing the strongest signals present is presented. Greater receiver sensitivity results from …

    nps Repository record for High Frequency (HF) radio signal amplitude characteristics, HF receiver site performance criteria, and expanding the dynamic range of HF digital new energy receivers by strong signal elimination (opens in a new tab)

  2. Integrating logarithmic wide dynamic range CMOS image sensors

    … scenes faithfully; a feature known as wide dynamic range (WDR). Current digital image sensors have a linear response that results in saturation and loss of details. Conventional CMOS image sensors with a logarithmic response attempt to address the limited dynamic range of the linear digital …

    oxford Repository record for Integrating logarithmic wide dynamic range CMOS image sensors (opens in a new tab)

  3. MOSFET Modulated Dual Conversion Gain CMOS Image Sensors

    … low-power operation. Previously proposed high dynamic range enhancement schemes focused mainly on extending the sensor dynamic range at the high illumination end. Sensor dynamic range extension at the low illumination end has not been addressed. Since most applications require low-noise, …

    boise Repository record for MOSFET Modulated Dual Conversion Gain CMOS Image Sensors (opens in a new tab)

  4. Investigations of radiation shielding, diagnostic methods and imaging for conventional and laser-driven radiation sources

    … were compared to GEANT4 simulations and Extended-Range Bonner Sphere Spectrometer (ERBSS) neutron spectra between 10^-9-10^2 MeV. The modelling of the gantry and the treatment room are relevant to reproduce the ERBSS data, especially in the thermal energy region (10^-2-10^1 MeV) of increased …

    lmu-germany Repository record for Investigations of radiation shielding, diagnostic methods and imaging for conventional and laser-driven radiation sources (opens in a new tab)

  5. Companding Flash Analog-To-Digital Converters

    … converter can be used to satisfy both the dynamic range and resolution requirements of an infrared imaging system. In the past, infrared imaging systems had to rely on analog electronics to process a thermal image. This was costly and, in many ways, inefficient but the only way to perform …

    ucf Repository record for Companding Flash Analog-To-Digital Converters (opens in a new tab)