Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"E-Mosquito"”.

  1. Needle and Potentiostat Study for Blood Glucose Monitoring: Third-Generation E-Mosquito

    … number of patients drop their treatments. E-Mosquito is a new concept: a minimally-invasive glucose monitor meant to replace the finger pricking test. The second-generation E-Mosquito has proven to be an effective device to access a blood sample without inflicting pain to the user. …

    calgary Repository record for Needle and Potentiostat Study for Blood Glucose Monitoring: Third-Generation E-Mosquito (opens in a new tab)

  2. Shape Memory Alloy-based Whole Blood Glucose Monitoring Device: The e-Mosquito

    … blood glucose monitoring, the e-Mosquito. The proposed design of the e-Mosquito device aims to extract whole blood sample from a small lanced skin wound using a novel shape memory alloy (SMA)-based microactuator and directly measure the blood glucose level from this sample. A …

    calgary Repository record for Shape Memory Alloy-based Whole Blood Glucose Monitoring Device: The e-Mosquito (opens in a new tab)

  3. Development and Microscaling of a Novel Glucose Biosensor for Application in a Minimally Invasive Sampling Platform

    … Shannon frequency of blood glucose levels. The e-Mosquito provides near-painless sampling, is apply-and-forget, and provides a higher sampling rate. This thesis concerns miniaturiziation of a novel glucose transducer, for integration in the e-Mosquito, that consists of iridium and glucose oxidase …

    calgary Repository record for Development and Microscaling of a Novel Glucose Biosensor for Application in a Minimally Invasive Sampling Platform (opens in a new tab)

  4. Electromechanical Shape Memory Alloy Actuators for Blood Extraction

    … drawing capillary blood for analysis by the e-Mosquito wearable, autonomous glucose monitoring system for diabetes. All the designs used contracting shape memory alloy wires, fixed geometry and millimetre-scale moving parts, primarily to extend a disposable lancet needle from the device and …

    calgary Repository record for Electromechanical Shape Memory Alloy Actuators for Blood Extraction (opens in a new tab)

  5. Efeitos da alternância de hospedeiros no fitness do Zika virus

    … um vírus de RNA transmitido majoritariamente por mosquitos Aedes aegypti. A alternância entre hospedeiro humano e mosquito impõe pressões seletivas distintas que podem influenciar a evolução e o fitness viral. Portanto, compreender como os vírus se adaptam a essa transição é fundamental para …

    brazil-ufsc Repository record for Efeitos da alternância de hospedeiros no fitness do Zika virus (opens in a new tab)