Inkjet-Printed ECG Electrodes and AI-based Data Reliability for Smart-Health CPS
… capture and monitoring of Electrocardiogram (ECG/EKG) signal is essential but challenging. To address the challenges, our research focuses on developing reliable, user-friendly, and economically viable solutions for interfacing and powering of CPS device and reliability of captured data from …
-
Material and Device Design Strategies for Suppressing the Foreign Body Response to Implantable Electronics
… applications via electrocardiography (ECG) in mice. Device design and a new surface functionalization strategy for substantially enhancing adhesion of ZIPH on plastic substrates are explored. We also discuss the (ECG) recording setup and amplifier design. Finally, we show that ZIPH ECG …
-
Material and Device Design Strategies for Suppressing the Foreign Body Response to Implantable Electronics
… applications via electrocardiography (ECG) in mice. Device design and a new surface functionalization strategy for substantially enhancing adhesion of ZIPH on plastic substrates are explored. We also discuss the (ECG) recording setup and amplifier design. Finally, we show that ZIPH ECG …
-
MONITORING NEUROMUSCULAR BLOCKADE AT THE ADDUCTOR POLLICIS AND ORBICULARIS OCULI WITH SPLIT DOSING OF MIVACURIUM CHLORIDE
… of the ulnar nerve was achieved by placing ECG electrodes 2 cm and 10 cm proximal to the distal end of the ulnar nerve. The same type ECG electrodes were used at the orbicularis oculi muscle group. One electrode was placed 2 cm lateral and 2 cm caudal to the outer canthus of the eye and the …
-
Silver nanowire/chitosan nanocomposite dry electrodes for electrocardiogram
… were used as in-vitro electrocardiogram (ECG) electrodes. ECG measurement results showed that higher nanowire loadings within the nanocomposites have better performance in terms of recording useful ECG signals. Results presented herein showed that the Ag NW/ chitosan nanocomposites have a …
-
Development of a multi-lead trans-thoracic impedance pneumograph for heart rate variability studies
… that measures respiratory tidal volume and ECG for use in heart rate variability studies, was designed, built and tested. The device developed is a Multi-Lead Trans-Thoracic Impedance Pneumograph, which determines tidal volume on a breath by breath basis, utilizing both hardware and …
-
Distribuição e orientação dos quimiorreceptores de O2 branquiais em tilápia-do-Nilo (Oreochromis niloticus): controle das respostas cardiorrespiratórias à hipóxia
… buccal and two opercular canullae, and a pair of ECG electrodes were implanted in a group of intact fish (control group, n = 10; Wt = 258.4 ± 7.4 g). This procedure served to measure the following cardiorespiratory variables: respiratory frequency - fR, ventilatory tidal volume - VT, gill …
-
ECG Authentication for Mobile Device
… algorithm based on electrocardiogram or ECG is proposed. In this system the user will only need to touch the ECG electrodes of the mobile device to gain access. With this authentication mode no one will be able to see the biometric pattern that is used to unlock the de vices. This will …
-
Preparation and application of cellulose based sensing materials
… are further tested as human motion sensors and ECG electrodes, marking significant strides in wearable technology. The second part of this work presents a super-elastic Carbon Black (CB) coated cellulose sub-micron fiber aerogel sensor, which is developed through ice-templating and electrostatic …
-
Development of soft biopotential sensors for electrocardiogram and electroencephalogram systems
… approach to long-term electrocardiography (ECG) and electroencephalogram for cardiovascular and neural diseases diagnosis and therapy. However, current ECG Holters are either in small size with limited vector information or in bulky size with cumbersome wirings. Besides, the conventional …
-
Advanced robust non-invasive foetal heart detection techniques during active labour using one pair of transabdominal electrodes
… using only a pair of transabdominal electrodes. The first and second techniques are, namely, the structured third- order cumulant-slice-template matching and the bispectral-contours-template matching for fetal QRS identification, respectively. The third technique is based on the …
-
Non-invasive electrical imaging of the heart
… activity of the heart from multiple thoracic ECG signals. The computational framework required to produce such electrical images of the heart from non-invasive torso surface signals is presented. It is shown reliable electrical images of the heart can be obtained under a controlled …
-
Modulação autonômica cardíaca durante o exercício no peixe de respiração aérea bagre africano, Clarias gariepinus
… Two groups of C.gariepinus were implanted with ECG electrodes under benzocaine anaesthesia, used to measure ƒH during exercise, routine between AB events, and ƒH Pre-AB and ƒH Post-AB. A peritoneal cannula was inserted to inject antagonist drugs, propranolol and atropine. In Group 1 (n = 9; 126 …
-
Hermetically-Encapsulated Precision Accelerometer Contact Microphones for Wearable Medical Devices
… by comparing it against a medical-grade ECG system. The results indicate a high correlation r2 = 0.98, verifying the use of the ACM for vital parameter monitoring in place of ECG electrodes without compromising on signal strength, quality, and accuracy, while providing additional benefits …
-
The role of PDE2 as a potential target for antiarrhythmic therapy in cardiovascular diseases
… PDE2 inhibition with BAY 60-7550 using ex vivo ECG electrodes. To assess the potential antiarrhythmic effects of PDE2 modulation under pathophysiological conditions, two different experimental models were induced in mice: (i) Heart failure (HF) was induced through a 5-week regimen including a …
-
The role of PDE2 as a potential target for antiarrhythmic therapy in cardiovascular diseases
… PDE2 inhibition with BAY 60-7550 using ex vivo ECG electrodes. To assess the potential antiarrhythmic effects of PDE2 modulation under pathophysiological conditions, two different experimental models were induced in mice: (i) Heart failure (HF) was induced through a 5-week regimen including a …
-
Automatizované měření vlastností zesilovačů biologických signálů
Tato bakalářská práce se věnuje zesilovačům pro biologické signály. V této práci jsou uvedeny základní elektrodiagnostické metody pro snímání biologických signálů. V práci je popsáno zpracování biologických signálů a druhy snímačů pro biologické signály. Dále je zde popsáno vývojové prostředí …
-
Automatizované měření vlastností zesilovačů biologických signálů
Tato bakalářská práce se věnuje zesilovačům pro biologické signály. V této práci jsou uvedeny základní elektrodiagnostické metody pro snímání biologických signálů. V práci je popsáno zpracování biologických signálů a druhy snímačů pro biologické signály. Dále je zde popsáno vývojové prostředí …
-
Establishment of normal limits of the electrocardiogram in healthy Nigerians using automated methods
Automated analysis of the electrocardiogram (ECG) has been of increasing importance over the past five decades. Establishment of the normal limits of the ECG in any population is the first step before computer application in ECG interpretation in that population. Normal limits of the ECG have been …
-
Cyklopočítač s měřičem frekvence
Bakalářská práce se zabývá návrhem a realizací cyklopočítače s měřičem frekvence šlapání. Zařízení měří rychlost, frekvenci šlapání, tepovou frekvenci, ujetou vzdálenost a také aktuální čas a datum. Naměřené hodnoty se ukládají do paměti a poté je lze prostřednictvím USB rozhraní přenést do …