Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 34 for “"EEDF"”.
-
Measurements of a DC Gas Discharge
… of the electron energy distribution function (EEDF). First, measurements of the discharge were performed including obtaining current-voltage (IV) characteristics and determining breakdown voltages for several gases. Images of discharges were recorded using a digital camera, and emission spectra …
-
Control of the Electron Energy Distribution and Plasma Ignition Delay in a Novel Dual Tandem Inductively Coupled Plasma
The electron energy distribution function (EEDF) plays an essential role in non-equilibrium low-temperature plasmas. The EEDF governs the rate of electron-impact reactions and determines the plasma gas composition, which in turn, determines the fluxes of radicals, ions, and photons striking the …
-
Ionization and Acceleration of Low-Temperature Magnetically Confined Plasma
… and electron energy distribution function (EEDF). A combined measurement of the Langmuir probe and laser-induced fluorescence provided an estimation of the Hall parameter, collision frequency, and axial electron. The plume was composed mostly of ions which were thermalized and made the EEDF …
-
A global model framework with self-consistent electron energy distribution for reaction kinetics in low-temperature plasmas
… electron energy distribution function (EEDF) profoundly affects reaction kinetics as many reactions depend on the electron energy. The Maxwellian EEDF is often assumed, leading to overestimated electron impact reaction rates and time evolution of species densities. A self-consistent EEDF …
-
Measurements of metastable atom density using energies and densities of energetic "fast" electrons detected in the electron energy distribution function associated with the afterglow plasma produced by a radio frequency inductively coupled plasma helium discharge.
… electron energy distribution function (EEDF), and metastable atom density in the afterglow of low-pressure (50 mTorr) helium radio-frequency inductively coupled plasma (RF-ICP) discharges were measured with a Langmuir probe. During the Afterglow period, sufficient time resolution was …
-
Langmuir probe measurements in 13.56MHz discharges
… the electron energy distribution function (eedf), in 13.56MHz argon and nitrogen plasmas under various discharge conditions. The development and application of the tuned probe is described, as is the rf environment, since successful measurements rely on a thorough understanding of the …
-
Plasma transport and development of plasma kinetics in ARIS
… the electron energy distribution function(EEDF). We explore the possibility of a magnetised boundary in the the diffusion chamber region by means of a multi-cusp magnetic array. A multi-cusp produces an effective field close to the boundary with low penetration on the plasma bulk. The …
-
INVESTIGATION OF LANGMUIR PROBES IN NON-MAXWELLIAN PLASMA USING PARTICLE-IN-CELL (PIC) MODELING
… the environment around LP in an EP system. The EEDF has been investigated with LP to overcome some limitations of Druyvesteyn method. The EEDF changes from Druyvesteyn to bi-Maxwellian with decreasing pressure. Therefore, bi-Maxwellian method was also implemented in the system to obtain utmost …
-
Measurements of electron energy distribution function and neutral gas temperature in an inductively coupled plasma
… The electron energy distribution function (EEDF), which contains important information of ICP plasma and is necessary for an accurate kinetic description of the low-pressure discharges, has been investigated with the Langmuir probe by using the alternating current (ac) method. Measurements …
-
Numerical modeling of low-pressure plasmas: applications to electric double layers
… the electron energy distribution function (eedf) is close to Maxwellian, except for its tail which is depleted at energies higher than the plasma potential. Evidence supporting that this depletion is mostly due to the high-energy electrons escaping to the walls is given. ¶ A new hybrid …
-
Bayesian uncertainty quantification of Langmuir probe and emission measurements applied to non-equilibrium argon and nitrogen plasmas
… the electron energy distribution function (EEDF), electron density and mean energy. Rigorous uncertainty quantification is applied throughout, using new Bayesian inversion frameworks to account for data, experimental and modeling uncertainties. The ten Ar($4p$) state population densities …
-
Advanced Control of Ion and Electron Energy Distributions and Investigation of in-situ Photo-Assisted Etching
… the electron energy distribution function (EEDF) and plasma density, a plasma reactor incorporating dual tandem plasma sources separated by a grid is presented. As feature sizes shrink to the nanometer scale, tuning the EEDF becomes increasingly important for both plasma etching and …
-
The particle trap and plasma parameter studies in an RF argon discharge
… nₑ, and electron energy distribution function (EEDF). The second objective is to investigate the forces acting on contaminant particle which can be generate during process. The final objective is to understand the physical nature of the plasma which is very sensitive to changes of processing …
-
An experimental investigation of heating mechanisms, mode transition and instabilities in a radio frequency inductively coupled plasma
… in the electron energy distribution function (EEDF) and the presence of metastable atoms Finally, a specific type of instability observed in low pressure ICPs is investigated experimentally and the results are found to agree on many points with a proposed model describing the instability.
-
Reconnection-Driven Electron Acceleration
… electron energy distribution functions (EEDFs) whose peak energies increase as the guide field decreases. A cross-over occurs at a guide field of 10, when the spatio-temporal production of energetic electrons in PHASMA increases dramatically. Measurements for this case reveal the …
-
Time dependent collisional radiative model of an extreme ultraviolet driven plasma
… non- Maxwellian electron distribution functions (EEDF) provided by the PIC model the CRM model calculates the argon excited state densities and the spontaneous photon emission rate. The results are compared to Optical Emission Spectroscopy measurements. The experiments show that the timescales on …
-
Hybrid Pumping Process for High-Power (TW-Class) Pulsed Gas Lasers
… data, the electron energy distribution function (EEDF), reaction rates, and mean electron energy ((e)) were computed across reduced electric fields of 1-1000 Td. Results show that efficient excitation occurs when (e) lies between 8-15 eV, corresponding to tens to low hundreds of Townsends, where …
-
Hybrid Pumping Process for High-Power (TW-Class) Pulsed Gas Lasers
… data, the electron energy distribution function (EEDF), reaction rates, and mean electron energy ((e)) were computed across reduced electric fields of 1-1000 Td. Results show that efficient excitation occurs when (e) lies between 8-15 eV, corresponding to tens to low hundreds of Townsends, where …
-
Hybrid Pumping Process for High-Power (TW-Class) Pulsed Gas Lasers
… data, the electron energy distribution function (EEDF), reaction rates, and mean electron energy ((e)) were computed across reduced electric fields of 1-1000 Td. Results show that efficient excitation occurs when (e) lies between 8-15 eV, corresponding to tens to low hundreds of Townsends, where …
-
Hybrid Pumping Process for High-Power (TW-Class) Pulsed Gas Lasers
… data, the electron energy distribution function (EEDF), reaction rates, and mean electron energy ((e)) were computed across reduced electric fields of 1-1000 Td. Results show that efficient excitation occurs when (e) lies between 8-15 eV, corresponding to tens to low hundreds of Townsends, where …
Page 1 of 2