Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 6 of 6 for “"ELF procedure"”.
-
Optimized Distribution of Strength in Buckling-Restrained Brace Frames in Tall Buildings
… as determined from the Equivalent Lateral Force (ELF) procedure. For tall buckling restrained braced frames (BRBFs), two questions remain unanswered: what brace distribution will minimize total brace area, while satisfying story drift and ductility limits, and is the ELF procedure an effective …
-
A Comparison of Optimized Nonlinear Time History Analysis and the Equivalent Lateral Forces Method for Brace Design
This thesis presents the development of a design procedure for buckling-restrained braced frames (BRBF's). This procedure uses nonlinear time history analysis and a formal optimization algorithm. The time history analysis includes an elasto-plastic model for the braces. The optimization algorithm …
-
Performance-based Seismic Design of Multi-Story Light-frame Wood Buildings using Adaptive Displacement-based Design Procedure
… the first story. The current force-based design procedure, namely the Equivalent Lateral Force (ELF) procedure, does not explicitly consider the contribution of non-structural elements. This research (1) studied soft-story deficiency in light-frame wood buildings due to unintended stiffness and …
-
Simplified Seismic Design for Mid-Rise Buildings with Vertical Combination of Framing Systems
… methods, i.e., modified equivalent lateral force procedure (ELF) and two-stage analysis procedures, are proposed to evaluate seismic loads of the combined framing systems. The simplified approaches to determine the required storey-stiffness arrangements and compute seismic loads are developed …
-
Shake table testing of a two-story CLT platform building
… building system. The Equivalent Lateral Force (ELF) procedure was used in the design of the stacked CLT shear walls, with the assumption that shear was resisted entirely by generic angle brackets, and the overturning moment was resisted by tie-down rods on either end of each shear wall. The …
-
Comparative response of mid-rise (9-story) based-isolated and conventional steel moment resisting frame buildings
… check with standard response spectrum analysis procedures. The OpenSees model was used for nonlinear pushover analysis and nonlinear response history analysis to suites of ground motions representing various probability of occurrence events. Eigenvalue analysis was carried out on the various …