Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"EMG control"”.

  1. EMG Control of an Upper-Limb Rehabilitation Exoskeleton for SCI Affected Users

    … interface are challenged with developing control schemes that can detect user intent and maximize their engagement. Electromyography (EMG) is a promising technique to address this challenge. In this thesis, an EMG control scheme for an upper-limb exoskeleton, the MAHI Exo-II, is designed …

    rice Repository record for EMG Control of an Upper-Limb Rehabilitation Exoskeleton for SCI Affected Users (opens in a new tab)

  2. An adaptive calibration and control method for EMG control of a robot arm

    … to interact with their environment. Robot arms controlled with residual muscle signals measured with electromyography give such individuals the chance to complete activities of daily living on their own. While such technologies are helpful in returning a degree of autonomy to these individuals, …

    texas Repository record for An adaptive calibration and control method for EMG control of a robot arm (opens in a new tab)

  3. An Investigation Of Electromyographic (Emg) Control Of Dextrous Hand Prostheses For Transradial Amputees

    … disease or an accident. Upper-limb prostheses controlled using surface Electromyography (sEMG) offer a solution to help the amputees; however, their functionality is limited by the small number of movements they can perform and their slow reaction times. Pattern recognition (PR)-based EMG …

    plymouth Repository record for An Investigation Of Electromyographic (Emg) Control Of Dextrous Hand Prostheses For Transradial Amputees (opens in a new tab)

  4. EVALUATION OF CONTINUOUS MULTIMODALITY HAPTIC FEEDBACK FOR UPPER-LIMB PROSTHETICS

    … use this sense of touch to regulate our motor control. Upper-limb amputees not only lose their ability to perform actions with their hands but also lose their sense of touch. While commercial prostheses are available to help amputees regain their ability to perform activities of daily living, …

    jhu Repository record for EVALUATION OF CONTINUOUS MULTIMODALITY HAPTIC FEEDBACK FOR UPPER-LIMB PROSTHETICS (opens in a new tab)

  5. Exploring factors associated with upper-limb prosthesis embodiment : a mixed-methods approach

    … to explore experimentally how the prosthesis control method influences PE (Study 3). Body ownership techniques were utilised in a virtual-hand illusion paradigm, combined with motion tracking of a myoelectric prosthesis. This tested the relative impact of electromyographic (EMG) control (via …

    salford Download PDF for Exploring factors associated with upper-limb prosthesis embodiment : a mixed-methods approach (opens in a new tab)

  6. Extracting signatures from muscle activity data for control of myolectric prosthesis

    Upper limb myoelectric prostheses are controlled by the voluntary contraction of residual muscles of the amputated limb. These contractions produce weak electric signals that can be captured using surface electromyography (sEMG) which can be used to control the prosthesis. A number of …

    strathclyde Repository record for Extracting signatures from muscle activity data for control of myolectric prosthesis (opens in a new tab)

  7. Design and Testing of an Agonist-Antagonist Position-Impedance Controlled Myoelectric Prosthesis

    Intuitive prosthetic control is limited by the inability to easily convey intention and perceive physical requirements of the task. Rather than providing haptic feedback and allowing users to consciously control every component of manipulation, relegating some aspects of control to the device may …

    vcu Repository record for Design and Testing of an Agonist-Antagonist Position-Impedance Controlled Myoelectric Prosthesis (opens in a new tab)

  8. Understanding Forearm Muscle Coordination in Children

    A combination of surface electromyography (EMG) and pattern recognition algorithms have led to improvements in the functionality of upper limb prosthetics. This method of control relies on user's ability to repeatedly generate consistent muscle contractions. Research in EMG based control of …

    ucf Repository record for Understanding Forearm Muscle Coordination in Children (opens in a new tab)

  9. Real-time embedded EMG analysis for human-computer interaction

    … (HCI) applications. Electromyographic (EMG) signals fall into this class of phenomena and are generally sensed at the skin’s surface. EMG signal analysis is popularly used for classifying a wide range of wrist-hand movements within prosthetic and gesture control equipment. To enable very …

    qu-belfast Repository record for Real-time embedded EMG analysis for human-computer interaction (opens in a new tab) Download PDF for Real-time embedded EMG analysis for human-computer interaction (opens in a new tab)

  10. On the Utility of Representation Learning Algorithms for Myoelectric Interfacing

    … movement. Once transduced via electromyography (EMG) and converted into digital form, this activity can be processed to provide an estimate of the original motor intent and is as such a feasible basis for non-invasive efferent neural interfacing. EMG-based motor intent decoding has so far …

    lund Repository record for On the Utility of Representation Learning Algorithms for Myoelectric Interfacing (opens in a new tab) Download PDF for On the Utility of Representation Learning Algorithms for Myoelectric Interfacing (opens in a new tab)

  11. Aktivní protéza ruky

    … some of their abilities. METHODS: In order to control such prostheses, a system is to be developed by which electromyographic (EMG) measurements on the upper extremities can be carried out. The data obtained in this way should then be processed to recognize different gestures. These EMG …

    brno-tech Repository record for Aktivní protéza ruky (opens in a new tab)