Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 13 of 13 for “"EO-1 Hyperion"”.

  1. Remote Sensing of Phragmites Australis with The EO-1 Hyperion Sensor

    … degradation. This study evaluates the utility of Hyperion hyperspectral remote sensing imagery and common image analysis software for detecting large monodominant stands of Phragmites in coastal wetlands. Two approaches to hyperspectral image classification- unsupervised classification and target …

    sdstate Repository record for Remote Sensing of Phragmites Australis with The EO-1 Hyperion Sensor (opens in a new tab)

  2. Use of EO-1 Hyperion to Perform Spectral Band Adjustment of Landsat-7 ETM+ and Terra Modis Sensors for Accurate Cross Calibration

    … in this thesis is to use Earth Observer (EO-1) Hyperion data to calculate and apply SBAF between Landsat 7 (L 7) Enhanced Thematic Mapper Plus (ETM+) and the Terra Moderate Resolution Imaging Spectroradiometer (MOD IS) for pseudo invariant test sites The motivation of the work comes from …

    sdstate Repository record for Use of EO-1 Hyperion to Perform Spectral Band Adjustment of Landsat-7 ETM+ and Terra Modis Sensors for Accurate Cross Calibration (opens in a new tab)

  3. Refinement Of Trend-To-Trend Cross Calibration Total Uncertainties Utilizing Extended Pseudo Invariant Calibration Sites (Epics) Global Temporally Stable Target

    … sensors, which involves taking nearly simultaneous images of a ground target to compare uncalibrated sensor to a well-calibrated reference sensor. This study introduces the hyperspectral Trend-to-Trend (T2T) cross-calibration technique utilizing EPICS Cluster 13 Global Temporally Stable …

    sdstate Repository record for Refinement Of Trend-To-Trend Cross Calibration Total Uncertainties Utilizing Extended Pseudo Invariant Calibration Sites (Epics) Global Temporally Stable Target (opens in a new tab)

  4. The Development of Dark Hyperspectral Absolute Calibration Model Using Extended Pseudo Invariant Calibration Sites at a Global Scale: Dark EPICS-Global

    … Instrument (MSI) , and Earth Observing One (EO-1) Hyperion data for the DAHAC model development, where well-calibrated L8 and S2A are used as the reference sensors while EO-1 Hyperion with 10 nm spectral resolution is used as a hyperspectral library. The dark hyperspectral dataset (DaHD) is …

    sdstate Repository record for The Development of Dark Hyperspectral Absolute Calibration Model Using Extended Pseudo Invariant Calibration Sites at a Global Scale: Dark EPICS-Global (opens in a new tab)

  5. Hyperspectral and Multispectral Image Analysis for Vegetation Study in the Greenbelt Corridor near Denton, Texas

    … studies in the greenbelt corridor near Denton. EO-1 Hyperion was the hyperspectral image and Landsat Thematic Mapper (TM) was the multispectral image used for this research. In the first part of the research, both the images were classified for land cover mapping (after necessary atmospheric …

    unt Repository record for Hyperspectral and Multispectral Image Analysis for Vegetation Study in the Greenbelt Corridor near Denton, Texas (opens in a new tab)

  6. Empirical Absolute Calibration Model for Multiple Pseudo-Invariant Calibration Sites

    … the reference radiometer and Earth Observing-1 (EO-1) Hyperion image data to provide a representative hyperspectral reflectance profile of the PICS. Data from a region of interest (ROI) in an “optimal region” of 3% temporal, spatial, and spectral stability within the PICS are used for developing …

    sdstate Repository record for Empirical Absolute Calibration Model for Multiple Pseudo-Invariant Calibration Sites (opens in a new tab)

  7. Hyperspectral Empirical Absolute Calibration Model Using Libya 4 Pseudo-Invariant Calibration Site

    … radiometer and using Earth Observing One (EO-1) Hyperion, with a spectral resolution of 10 nm as a hyperspectral source. This model utilizes data from a region of interest (ROI) in an “optimal region” of 3% temporal, spatial, and spectral stability within the Libya 4 PICS. It uses an …

    sdstate Repository record for Hyperspectral Empirical Absolute Calibration Model Using Libya 4 Pseudo-Invariant Calibration Site (opens in a new tab)

  8. Using multispectral and hyperspectral satellite data for early detection of mountain pine beetle damage

    … data; the third question was investigated using EO-1 Hyperion hyperspectral data. Using a multi-step deductive approach, MPB-attacked stands were identified with an accuracy of 69% using the Landsat imagery, approximately four months earlier than would be possible with conventional surveys. …

    ubc Repository record for Using multispectral and hyperspectral satellite data for early detection of mountain pine beetle damage (opens in a new tab) Download PDF for Using multispectral and hyperspectral satellite data for early detection of mountain pine beetle damage (opens in a new tab)

  9. Theoretical and Applied Radiometric Cross-calibration of Satellite Optical Sensors

    This study focuses on theoretical and applied understanding of radiometric cross-calibration of optical sensors over their entire missions in support of continued long-term studies of the Earth's land surfaces. The two sensors used for the study are the Terra Moderate Resolution Imaging …

    sdstate Repository record for Theoretical and Applied Radiometric Cross-calibration of Satellite Optical Sensors (opens in a new tab)

  10. Mediterranean forest species mapping using hyperspectral imagery

    … of Mediterranean forest species, based on EO-1 Hyperion satellite spectral imagery (30m, 196 channels). Two pixel-level analysis methodologies were evaluated, based on Spectral Angle Mapper (SAM) and Support Vector Machines (SVM), as well as an object-based analysis methodology (GEOBIA). …

    greece Repository record for Mediterranean forest species mapping using hyperspectral imagery (opens in a new tab)

  11. An Updated Radiometric Calibration of the Hyperion Sensor

    … calibrate a hyperspectral sensor, the EO-1 Hyperion, by first performing cross calibration with a multispectral sensor, the Landsat 7 ETM+, and then absolute radiometric calibration using the reflectance based approach of vicarious calibration. The test site used for the …

    sdstate Repository record for An Updated Radiometric Calibration of the Hyperion Sensor (opens in a new tab)

  12. Assessment of Woody Biomass and Solar Energy Resources with Remote Sensing and GIS Techniques : A Regional Study in the High Mountains of the Eastern Pamirs (Tajikistan)

    Energy issues have been a main concern of geographical research in the Eastern Pamirs of Tajikistan. Dwarf shrubs (Krascheninnikovia ceratoides, Artemisia spp.), as the only woody vegetation, are of central importance in this context by representing a key thermal energy resource. But despite their …

    bayreuth Repository record for Assessment of Woody Biomass and Solar Energy Resources with Remote Sensing and GIS Techniques : A Regional Study in the High Mountains of the Eastern Pamirs (Tajikistan) (opens in a new tab)

  13. Estimating the water quality condition of river and lake water in the Midwestern United States from its spectral characteristics

    … focuses on the calibration of an existing bio-geo-optical model for studying the spatial variability of chl, non-algal particles (NAP), and colored dissolved organic matter (CDOM) in episodic St. Joseph River plumes in southern Lake Michigan. One set of EO-1 Hyperion imagery and one set of …

    purdue-thes Repository record for Estimating the water quality condition of river and lake water in the Midwestern United States from its spectral characteristics (opens in a new tab)