Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 53 for “"EPID"”.

  1. EPID-based Dose Verification for Adaptive Radiotherapy

    … and the delivered dose. Although placement of an EPID behind the patient during treatment allows for exit dosimetry which may be used to reconstruct the delivered patient dose via backprojection of the fluence, there have not been any studies examining the basic assumption of backprojection-based …

    vcu Repository record for EPID-based Dose Verification for Adaptive Radiotherapy (opens in a new tab)

  2. 2d dose measurement using a flat panel EPID

    … silicon electronic portal imaging device (a-Si EPID) to complement the film. The dosimetric behaviour of the device is studied both experimentally and numerically using the EGSnrc Monte Carlo simulation routine. The intrinsic build-up of the flat panel EPID was found to be 1.1 cm of water …

    ubc Repository record for 2d dose measurement using a flat panel EPID (opens in a new tab) Download PDF for 2d dose measurement using a flat panel EPID (opens in a new tab)

  3. EPID dosimetry in intensity modulated radiation therapy applications.

    Electronic Portal Imaging Devices (EPIDs) can be used for dosimetric purposes, provided that an appropriate dosimetric calibration is used. However, in most studies published so far, transmitted dose maps, measured using EPIDs, are used under limited conditions only and further investigation is …

    adelaide Repository record for EPID dosimetry in intensity modulated radiation therapy applications. (opens in a new tab)

  4. Early parent interaction with deaf children: developing the EPID Tool

    … (2) to gain consensus on the core content of the EPID tool Results: Though methods of assessment are different between researchers and practitioners, both tend to assess the following parental skills: attention getting, joint engagement, parental sensitivity, and how a parent provides access to, …

    city-london Download PDF for Early parent interaction with deaf children: developing the EPID Tool (opens in a new tab)

  5. Towards EPID-based 3D in vivo dosimetry for modern radiation therapy

    … This project proposes a methodology for EPID-based in vivo dosimetry, combining the accuracy of Monte Carlo (MC) methods for dose simulation in patient geometry, with the time-efficiency of deep neural networks. The Deep Dose Estimation (DDE) network, originally developed for dose …

    lmu-germany Repository record for Towards EPID-based 3D in vivo dosimetry for modern radiation therapy (opens in a new tab)

  6. In vivo δοσιμετρία ακτινοθεραπευτικής δέσμης φωτονίων με χρήση a-Si EPID.

    … is the validation of a new easily applicable EPID dosimetry method based on the back projection approach and the comparison of this method with the EBT2 film dosimetry method.Methods: The dosimetric characteristics of the EPID were determined. The methodology to calculate the dose on the …

    greece Repository record for In vivo δοσιμετρία ακτινοθεραπευτικής δέσμης φωτονίων με χρήση a-Si EPID. (opens in a new tab)

  7. Simulation of the transmitted dose in an EPID using a Monte Carlo method

    … Chamber (SLIC) Electronic Portal Imaging Device (EPID) for calculations of transmitted dose in the EPID. The project was divided into two parts. The head of a 6 MV Varian 600C/D photon linac was first simulated by BEAMnrc. The modelling parameters such as the electron beam energy and the Full …

    adelaide Repository record for Simulation of the transmitted dose in an EPID using a Monte Carlo method (opens in a new tab)

  8. Automated review of patient position during DIBH breast hybrid IMRT using EPID images

    … by using electronic portal imaging device (EPID) images acquired in each fraction. Three image-processing algorithms were evaluated on their ability to accurately measure the chest wall position (CWP) in EPID images. One of the algorithms is based on the use of the Canny filter while the …

    manitoba Repository record for Automated review of patient position during DIBH breast hybrid IMRT using EPID images (opens in a new tab)

  9. Four-Dimensional In Vivo Dosimetry By Dose Reconstruction Using Continuous Epid Images And Phase Sorting Method

    … in using an electronic portal imaging device (EPID) for in vivo dosimetry, by correlating pixel values of measured EPID images to three-dimensional (3D) dose in the patient. In this research, a non-iterative dose reconstruction method has been employed, which utilizes phantom and EPID response …

    ecu Repository record for Four-Dimensional In Vivo Dosimetry By Dose Reconstruction Using Continuous Epid Images And Phase Sorting Method (opens in a new tab)

  10. 2D transit dosimetry using electronic portal imaging device

    … silicon electronic portal imaging device (a-Si EPID) was originally designed for positional verification in radiotherapy. Several feature of the a-Si EPID, such as the high-resolution detector array and ease of operation, have made this imaging device an attractive tool for dose measurements. …

    glasgow Download PDF for 2D transit dosimetry using electronic portal imaging device (opens in a new tab)

  11. Robust and efficient process for acceptance testing of radiation therapy machines

    … using the electronic portal imaging device (EPID). The project aimed to 1) show that the variability in EPID response can be normalized and that EPID can be used for correlating beam energy changes, 2) show that AT of a linac can be automated and can be performed using EPID as the measurement …

    missouri Repository record for Robust and efficient process for acceptance testing of radiation therapy machines (opens in a new tab)

  12. in vivo patient dose verification of volumetric modulated arc therapy including stereotactic body radiation treatment applications using portal dose images

    … silicon electronic portal imaging device (a-Si EPID). A geometrical characterization of the linear accelerator (linac) during VMAT delivery was performed. An angle adjustment method was determined which improves each EPID’s angular accuracy to within ±1° of the true physical angle. SBRT delivers …

    manitoba Repository record for in vivo patient dose verification of volumetric modulated arc therapy including stereotactic body radiation treatment applications using portal dose images (opens in a new tab)

  13. A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices

    … of using an Electronic Portal Imaging Device (EPID) for dose verification. However, EPIDs have limitations stemming from the non-uniform backscatter due to the support-arm as well as from scatter, glare, and an increased sensitivity to low-energy photons. None of these effects is typically …

    mcmaster Repository record for A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices (opens in a new tab)

  14. Portal Imaging Using a CSI (TL) Scintillator Coupled to a Cooled CCD Camera

    … A prototype electronic portal imaging device (EPID) was built, using a 12.7 mm thick, 20.32 cm diameter, CsI (Tl) scintillator, coupled to an Astromed ® liquid nitrogen cooled CCD TV camera. The system geometry of the prototype EPID was optimized to achieve high spatial resolution. Experimental …

    tenn-hsc Repository record for Portal Imaging Using a CSI (TL) Scintillator Coupled to a Cooled CCD Camera (opens in a new tab)

  15. Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device

    … format makes electronic portal imaging devices (EPIDs) good candidates for in vivo dosimetry. Currently there is no commercial transit dosimetry module, which could facilitate routine in vivo dosimetry with the EPID. Some centres are developing their in-house packages, and they are under …

    glasgow Download PDF for Transit dosimetry based on water equivalent path length measured with an amorphous silicon electronic portal imaging device (opens in a new tab)

  16. An electronic portal image-based monte carlo approach to in-vivo dosimetry for intensity modulated radiation therapy

    … model. Use of the amorphous-silicon detector (or EPID, for Electronic Portal Imaging Device), available on many linear accelerators, provides a solution. We hypothesize that non-transit dose images from the EPID provide us with information regarding certain delivery errors. To obtain this …

    ubc Repository record for An electronic portal image-based monte carlo approach to in-vivo dosimetry for intensity modulated radiation therapy (opens in a new tab) Download PDF for An electronic portal image-based monte carlo approach to in-vivo dosimetry for intensity modulated radiation therapy (opens in a new tab)

  17. Dosimetric verification of radiation therapy including intensity modulated treatments, using an amorphous-silicon electronic portal imaging device

    … silicon electronic portal imaging device (a-Si EPID), but the technique is applicable to any planar imager. A detailed, physics-motivated fluence model was developed to characterize fluence exiting the linear accelerator head. The model was further refined using results from Monte Carlo …

    manitoba Repository record for Dosimetric verification of radiation therapy including intensity modulated treatments, using an amorphous-silicon electronic portal imaging device (opens in a new tab)

Page 1 of 3