Showing 1 to 10 of 10 for “"EPID dosimetry"”.

  1. EPID dosimetry in intensity modulated radiation therapy applications.

    Electronic Portal Imaging Devices (EPIDs) can be used for dosimetric purposes, provided that an appropriate dosimetric calibration is used. However, in most studies published so far, transmitted dose maps, measured using EPIDs, are used under limited conditions only and further investigation is …

    adelaide Repository record for EPID dosimetry in intensity modulated radiation therapy applications. (opens in a new tab)

  2. In vivo δοσιμετρία ακτινοθεραπευτικής δέσμης φωτονίων με χρήση a-Si EPID.

    … is the validation of a new easily applicable EPID dosimetry method based on the back projection approach and the comparison of this method with the EBT2 film dosimetry method.Methods: The dosimetric characteristics of the EPID were determined. The methodology to calculate the dose on the …

    greece Repository record for In vivo δοσιμετρία ακτινοθεραπευτικής δέσμης φωτονίων με χρήση a-Si EPID. (opens in a new tab)

  3. in vivo patient dose verification of volumetric modulated arc therapy including stereotactic body radiation treatment applications using portal dose images

    … silicon electronic portal imaging device (a-Si EPID). A geometrical characterization of the linear accelerator (linac) during VMAT delivery was performed. An angle adjustment method was determined which improves each EPID’s angular accuracy to within ±1° of the true physical angle. SBRT delivers …

    manitoba Repository record for in vivo patient dose verification of volumetric modulated arc therapy including stereotactic body radiation treatment applications using portal dose images (opens in a new tab)

  4. 2D transit dosimetry using electronic portal imaging device

    … silicon electronic portal imaging device (a-Si EPID) was originally designed for positional verification in radiotherapy. Several feature of the a-Si EPID, such as the high-resolution detector array and ease of operation, have made this imaging device an attractive tool for dose measurements. …

    glasgow Download PDF for 2D transit dosimetry using electronic portal imaging device (opens in a new tab)

  5. A theoretical evaluation of transmission dosimetry in 3D conformal radiotherapy.

    Two-dimensional transmission dosimetry in radiotherapy has been discussed in the literature for some time as being a potential method for in vivo dosimetry. However, it still remains to become a wide spread practice in radiotherapy clinics. This is most likely due to the variety in radiotherapy …

    adelaide Repository record for A theoretical evaluation of transmission dosimetry in 3D conformal radiotherapy. (opens in a new tab)

  6. Developing a tri-hybrid algorithm to predict patient x-ray scatter into planar imaging detectors for therapeutic photon beams

    In vivo dosimetry via transmission imaging of the therapy beam can verify the intended treatment plan was delivered to the patient. However, the EPID (electronic portal imaging device) transmission images are contaminated with patient-generated scattered photons. If this component can be accurately …

    manitoba Repository record for Developing a tri-hybrid algorithm to predict patient x-ray scatter into planar imaging detectors for therapeutic photon beams (opens in a new tab)

  7. A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices

    … of using an Electronic Portal Imaging Device (EPID) for dose verification. However, EPIDs have limitations stemming from the non-uniform backscatter due to the support-arm as well as from scatter, glare, and an increased sensitivity to low-energy photons. None of these effects is typically …

    mcmaster Repository record for A Study of IMRT Pre-Treatment Dose Verification Using a-Si Electronic Portal Imaging Devices (opens in a new tab)

  8. Verification of the delivered patient radiation dose for non-coplanar beam therapy

    … of more stringent quality assurance. In vivo dosimetry based on the analysis of megavoltage transmission images acquired with an Electronic Portal Imaging Device (EPID) is a powerful quality assurance method that validates the actual delivered 3D dose to the patient. Currently, CancerCare …

    manitoba Repository record for Verification of the delivered patient radiation dose for non-coplanar beam therapy (opens in a new tab)