Efecto de las variables determinantes del flujo sanguíneo cerebral sobre los valores de NIRS intraoperatorio
… of cerebral blood flow, and the CO2 levels (etCO2), the mean arterial pressure (PAM) and the inspired oxygen fraction (FiO2). Methods: Longitudinal observational study of 64 patients undergoing to elective surgery under general anesthesia in the Fundación Cardioinfantil. Before and during …
-
Improving the care of preterm infants: before, during, and after, stabilisation in the delivery room
… producing mannequin, qualitative end tidal CO2 (EtCO2) detectors, a bespoke quantitative EtCO2 detector, and annotated videos of infant stabilisation as well as NICU procedures Results Manual ventilation improved with the use of EtCO2 detection, and was positively assessed by trainees. …
-
Avaliações hemogasométricas e cardiocirculatórias em cadelas pré-púberes e adultas submetidas à ovariossalpingohisterectomia por videocirurgia e por laparotomia
… Foram registrados FC, FR, PAS, PAM, PAD, T°C, ETCO2, tempo inspiratório e pressão de pico inspiratória e, colhidas amostras de sangue arterial para mensuração de pH, SaO2 (%); PaO2 (mmHg); PaCO2 (mmHg); HCO3 - (mmol/L), EB e TCO2. Tomando como base os valores de PaCO2 e ETCO2 encontrados, foi …
-
CEREBRAL BLOOD FLOW DURING CARDIOPULMONARY RESUSCITATION
… (LVCC) has been shown to improve end-tidal CO2 (ETCO2) and arterial blood pressure (BP). Using a porcine model, we hypothesized that, consistent with improved ETCO2 and BP, LVCC will promote greater cerebral blood flow (CBF) than SCC. Methods: Female pigs (N=32; 35±2 kg) were systematically …
-
Implementing Noninvasive Capnography Monitoring to Enhance Early Recognition of Postoperative Respiratory Decline in High-Risk Patients: A Quality Improvement Project
… of PACU staff on the use of non-invasive ETCO2 monitoring occurred, the implementation of non-invasive ETCO2 monitoring in the PACU was used to monitor identified patients, and data reports were collected from electronic health records to evaluate results. Pre- and post-intervention rates …
-
Devices to Improve Interoperability Between Simulators and Clinical Devices for Simulation-Based Resuscitation Training and Research
… pad placement. 2. The End Tidal Carbon Dioxide (ETCO2) Sensor Signal Generator allows users to display and control an ETCO2 waveform and numeric values on compatible clinical defibrillators and monitors. 3. The Zoll R Series Defibrillator Emulator interfaces pre-existing CPR performance …
-
ΤΟ ΙΣΟΦΛΟΥΡΑΝΙΟ ΣΤΙΣ ΝΕΥΡΟΧΕΙΡΟΥΡΓΙΚΕΣ ΕΠΕΜΒΑΣΕΙΣ
… PRESSURE (MAP), BLOOD GASES, END-TIDAL CO2 (ETCO2). ISOFLURANE DID NOT CAUSE ANY SIGNIFICANT CHANGE IN ICP, CVP, AND HR. MAP WAS DECREASED SIGNIFICANT AND THE HIGHER ISOFLURANE CONCENTRATION (P<0,001), PH AND PAO2 WERE NO SIGNIFICANT CHANGED (P<0,1), ETCO2 WAS 2,8-3,0%. FROM ALL THESE ABOVE …
-
The Effect of Local Anesthesia When Used in Dental Restorative Cases Under General Anesthesia on Control of Intraoperative Physiologic Parameters and Post-Operative Comfort
… in heart rate, and respiratory rate, ETCO2. Results: No statistically significant differences in FLACC score and PPPM score were seen between the two treatment groups. Intraoperatively, patients treated with preemptive LA had statistically significant lower heart rates and ETCO2 than …
-
Retinal Vascular Reactivity to Incremental Hyperoxia During Isocapnia
… enabled the specific control of end-tidal CO2 (ETCO2) and fractional expired O2 (FeO2), independent of each other and of minute ventilation. The specific aims of each chapter are as follows: Chapter 3: To compare the magnitude and variability of the retinal vascular reactivity response to an …
-
Nasal/Oral Automatic Sampling System in Oral/Maxillofacial Surgery
… method to monitor end-tidal carbon dioxide (EtCO2) for a patient who is under general anesthesia. It can monitor a patient's ventilation during sedation accurately. However, in the oral and maxillofacial surgery, the patients must open their mouth. The capnography reading will be unreliable …
-
Increasing staff comfort in performing conscious sedation during brachytherapy : a teaching quality improvement project
… rescue equipment, and end-tidal carbon dioxide (EtCO2) monitoring. Workshop efficacy was measured by comparing pre- and post-workshop reported comfort levels of the providers via survey. Results: Post-intervention survey results show an overall increase in comfort levels from 29% to 67%, with the …
-
Validation of Non-Invasive CO<sub>2</sub> Tolerance Field Test
… of a second CO2T field test, end-tidal CO2 (EtCO2), and lactate (BL) measurements during the repeated Wingate tests. STATISTICS: Repeated measures ANOVA and paired t-test were used to determine if differences existed between CO2T times, EtCO2, anaerobic capacity (AC), and blood BL values. …
-
Επιπτώσεις στην καρδιοαναπνευστική λειτουργία παιδιών από την χρήση προστατευτικής μάσκας
… (HR), τελο-εκπνευστικής συγκέντρωσης CO2 (EtCO2) και αναπνοών (RR). Πριν και μετά την CPET μετρήθηκε η μέγιστη εισπνευστική ρινική ροή (nPIF). Οι συμμετέχοντες πραγματοποίησαν δύο CPET, μία χωρίς μάσκα και μία με τυπική χειρουργική μάσκα, με τυχαία σειρά και με διάλειμμα 45 λεπτών μεταξύ …
-
MAGNETIC RESONANCE IMAGING OF CEREBRAL VENOUS OXYGENATION
… Yv variations. We found that end-tidal CO2 (EtCO2) positively correlated with Yv and explained approximately 50% of inter-subject Yv variations. These findings were reproducible in two different populations (young and elderly) and on two different MR systems (Philips and Siemens). Moreover, …
-
Carbon Dioxide Pneumoperitoneum and Laparoscopic Ovariectomy in the Domestic Rabbit (Oryctolagus cuniculus)
… indices (CI, SVI); heart rate; end-tidal CO2 (ETCO2); blood gases (PaCO2, PaO2); peak inspiratory pressure (PIP); and peripheral oxygen saturation (SpO2). Heart rate, SpO2, and ABP were unaffected by IAP. For PaO2, an interaction effect was seen between IAP and pressure sequence. PaCO2 …
-
Incidence of hypoxaemia with intravenous fentanyl and midazolam sedation in adult patients undergoing oral surgery procedures
… each 1% reduction in SpO2 and 1kPa reduction in EtCO2 from baseline by 190% and 192%, respectively. The risk of moderate and severe hypoxaemia increased by 7% (p=0.0003) & 8% (p = 0.0002) respectively, for each added year of age. Conclusions: This study presents information on the incidence of …
-
Evaluation of a Quality Improvement Intervention for Anesthetic Management of Acute Ischemic Stroke Patients Undergoing Endovascular Therapy
… in respiratory parameters were identified (EtCO2>40 mmHg, EtCO2<30 mmHg, SpO2<92%). The subjects in post-intervention phase had lower in-hospital all-cause mortality, (adjusted OR 0.67 [0.55-0.80]; p<0.0005), higher likelihood of favorable neurologic outcome (mRS≤2, adjusted OR 1.27 …
-
Efeitos cardiorrespiratórios e hemogasométricos da ventilação controlada com pressão positiva expiratória final associada ao pneumoperitônio com dióxido de carbono em coelhos
… pressão parcial de CO2 no final da expiração (EtCO2), frequência cardíaca (FC), pressão arterial diastólica (PAD), pressão arterial sistólica (PAS), pressão arterial média (PAM) e temperatura foram avaliadas em diferentes momentos da anestesia. Os animais foram submetidos à eutanásia nos …
-
Avaliação do sono em pacientes com mucopolissacaridose tipo VI
… e do pico do dióxido de carbono final exalado (EtCO2) 44,1 ± 6,01 mmHg. A ocorrência de apnéias centrais foi rara. Quatorze indivíduos da amostra (50%) tiveram evidência de hipertensão pulmonar (HP) documentada através de ecocardiograma. Foi observada associação positiva entre a média e o nadir …
-
Globaler zerebraler Blutfluss und linksventrikuläre systolische Herzfunktion
… 3\. Unter Berücksichtigung der gemessenen EtCO2-Werte und anderer Faktoren, wie Blutdruck, BMI, Herzfrequenz, LVEF, HMV, CI ergab sich für den Parameter LVEF, jedoch nicht für das HMV oder den CI ein signifikanter Zusammenhang. Die lediglich für einen Outputparameter positiven …