  1. Using multiple parameters to compare effluent quality of eight wastewater treatment systems.

    Wastewater effluent qualities from two study sites in central Texas were compared using whole effluent toxicity (WET) tests and chemical indicator parameters. Three of the effluents were collected from the City of Whitney Wastewater Treatment Facility in Whitney, TX; the remaining five effluents …

    baylor Repository record for Using multiple parameters to compare effluent quality of eight wastewater treatment systems. (opens in a new tab)

  2. Effect of coagulation and flocculation technology on bleached kraft mill effluent quality

    … has removed 60±4% of the biologically treated effluent colour. Over the same period, BOD5 was reduced by 26% and TSS was increased by 19 mg/L across tertiary treatment. This study revealed that the colour removal system removed 24%, 23%, 80%, and 18% of the COD, AOX, 2,3,7,8-TCDF, and mixed …

    ubc Repository record for Effect of coagulation and flocculation technology on bleached kraft mill effluent quality (opens in a new tab) Download PDF for Effect of coagulation and flocculation technology on bleached kraft mill effluent quality (opens in a new tab)

  3. Effect of Solids Retention Time on Activated Sludge Properties and Effluent Quality

    … or sludge age on activated sludge properties and effluent quality was investigated using laboratory scale reactors. It was found that an increase in SRT resulted in an increase in effluent solution polysaccharide, with the < 3,000 daltons (3K) size fraction contributing up to 68 percent of …

    vt Repository record for Effect of Solids Retention Time on Activated Sludge Properties and Effluent Quality (opens in a new tab)

  4. Energy Production and Effluent Quality in Tubular Digesters Treating Livestock Waste in Rural Costa Rica

    … benefits. However, careful use of digester effluent as a soil amendment is required due to the potential presence of protozoan parasites Cryptosporidium parvum and Giardia lamblia. This research investigated the performance of four tubular digesters in the Monteverde region of Costa Rica. …

    usf Repository record for Energy Production and Effluent Quality in Tubular Digesters Treating Livestock Waste in Rural Costa Rica (opens in a new tab)

  5. Effect of Feed Rate and Solid Retention Time (SRT) on Effluent Quality and Sludge Characteristics in Activated Sludge Systems Using Sequencing Batch Reactors

    … the PFR configurations produce better sludge quality, in terms of settleability and dewaterability, and subsequently better effluent quality than CSTR systems. In this experiment, the effect of SRT and substrate loading rate on activated sludge was investigated using bench scale SBRs. PFR and …

    vt Repository record for Effect of Feed Rate and Solid Retention Time (SRT) on Effluent Quality and Sludge Characteristics in Activated Sludge Systems Using Sequencing Batch Reactors (opens in a new tab)

  6. DYNAMIC MEMBRANE TECHNOLOGY FOR MUNICIPAL WASTEWATER TREATMENT

    … tank served the dual purpose of maintaining effluent quality in the event of biomass washouts, as well as enhancing the effluent quality in terms of COD and SS. The DM layer could be easily washed off the mesh surface by purely physical cleaning without the need for chemical cleaning required …

    nus Repository record for DYNAMIC MEMBRANE TECHNOLOGY FOR MUNICIPAL WASTEWATER TREATMENT (opens in a new tab) Download file for DYNAMIC MEMBRANE TECHNOLOGY FOR MUNICIPAL WASTEWATER TREATMENT (opens in a new tab)

  7. The influence of nitrogen and sludge age change in reactor performance and biopolymer production in activated sludge

    … to sludge a settling characteristic and effluent quality. In order to obtain the sludge samples for the analyses, two completely mixed, continuous flow activated sludge systems were maintained during this research. Raw wastewater from the Celanese Fiber Plant located at Narrows, Virginia …

    vt Repository record for The influence of nitrogen and sludge age change in reactor performance and biopolymer production in activated sludge (opens in a new tab)

  8. Evaluation of Greywater and A/C Condensate for Water Reuse: An Approach using Artificial Neural Network Modeling

    … (UV), and reverse-osmosis (RO). GAC-MI-ME effluent-quality was analyzed for greywater from laundry, shower, and wash basin. High-grade effluent equivalent to unrestricted water reuse was observed at UF and RO units. A subsequent tool (GREY-ANN) was proposed for GAC-MI-ME effluent quality …

    tamu Repository record for Evaluation of Greywater and A/C Condensate for Water Reuse: An Approach using Artificial Neural Network Modeling (opens in a new tab)

  9. Application of Low Pressure Reverse Osmosis Membranes for the treatment of UASB effluent

    … of Upflow Anaerobic Sludge Bioreactor (UASB) effluent with the goal of water reuse. The parameters studied were included the flux profile, constituent rejection, and membrane resistance changes. An investigation into the effectiveness of pre-treatment by GAC column and a study of fouling …

    guelph Repository record for Application of Low Pressure Reverse Osmosis Membranes for the treatment of UASB effluent (opens in a new tab)

  10. Food Waste Composition and Biological Hydrolysis Pretreatment Effect on Anaerobic Digestion: Performance and Modeling

    … of the FW can improve digestion and reduce effluent levels of organic mater, reducing downstream requirements for discharging the liquid stream. Organic loading rate is a key operational parameter which determines the methane yield, volumetric production, and effluent quality of an AD …

    guelph Repository record for Food Waste Composition and Biological Hydrolysis Pretreatment Effect on Anaerobic Digestion: Performance and Modeling (opens in a new tab)

  11. Assessment of ultraviolet light disinfection efficiency of advanced wastewater treatment plant effluent

    … of a 3-bank UV disinfection system for filter effluent from the Clark County Advanced Wastewater Treatment Plant has shown {dollar}>{dollar}4-log removal of seeded MS-2 coliphage at UV dosages of 80-100 milliwatt-seconds per square centimeter (mW-s/cm{dollar}\sp2{dollar}), and consistent …

    unlv Repository record for Assessment of ultraviolet light disinfection efficiency of advanced wastewater treatment plant effluent (opens in a new tab) Download PDF for Assessment of ultraviolet light disinfection efficiency of advanced wastewater treatment plant effluent (opens in a new tab)

  12. Characterization, Treatment, and Improvement of Aquacultural Effluents

    During the water quality and sludge characterization phase, average effluent quality over the course of a day was not found to be impaired during a 7-month sampling and monitoring study at the three trout farms. However, effluent quality was found to change significantly during times of high farm …

    vt Repository record for Characterization, Treatment, and Improvement of Aquacultural Effluents (opens in a new tab)

  13. Response of wild fish to municipal wastewater treatment plant upgrades

    … Primarily in response to the introduction of new effluent quality standards, the Region of Waterloo has invested millions of dollars to upgrade several of its MWWTPs including the facility servicing Kitchener, creating a unique opportunity to conduct a before-and-after study. The main objective of …

    waterloo Repository record for Response of wild fish to municipal wastewater treatment plant upgrades (opens in a new tab)

  14. Application of Landfill Treatment Approaches for the Stabilization of Municipal Solid Waste

    … was reduced relative to mature waste. Leachate quality improved for all FBs but through different mechanisms. Flushing was the most effective approach at removing biodegradable components and improving leachate quality. A mass balance on carbon and nitrogen revealed that a significant fraction …

    ucf Repository record for Application of Landfill Treatment Approaches for the Stabilization of Municipal Solid Waste (opens in a new tab)

  15. Changes in Septic Tank Effluent Due to Water Softener Use

    … plants can lead to deflocculation and poor effluent quality. Therefore, it is logical to assume that high sodium levels that result from the exchange of calcium and magnesium for sodium in home softeners could give rise to poor effluent quality from septic tanks, leading to shortened lives …

    vt Repository record for Changes in Septic Tank Effluent Due to Water Softener Use (opens in a new tab)

  16. A field study of a household package treatment plant

    … installation and operation practices, an average effluent of 85 mg/l BOD and 79 mg/l SS. Under similar circumstances, the type CA5-E plant produced an average effluent quality of 67 mg/l BOD and 56 mg/l SS. As neither type of plant operated with a VSS concentration of greater than 150 mg/l, the …

    ubc Repository record for A field study of a household package treatment plant (opens in a new tab) Download PDF for A field study of a household package treatment plant (opens in a new tab)

  17. Biological Nutrient Removal (BNR) Process Optimization and Recovery of Embedded Energy Using Biodiesel By-product

    … to the BNR system. Both systems had similar effluent quality and achieved total nitrogen (TN) and total phosphorus (TP) removals up to 86% and 92% respectively. The 5-stage BardenphoTM BNR experiment investigated the location of glycerol addition (direct vs. fermented) on the performance of …

    ucf Repository record for Biological Nutrient Removal (BNR) Process Optimization and Recovery of Embedded Energy Using Biodiesel By-product (opens in a new tab)

  18. Bioflocculation: Implications for Activated Sludge Properties and Wastewater Treatment

    … important in determining settling, dewatering, effluent and digested sludge properties (activated sludge properties) and may be vital to the function of all processes related to the above properties. In these studies, it was shown that divalent cations such as calcium and magnesium improved …

    vt Repository record for Bioflocculation: Implications for Activated Sludge Properties and Wastewater Treatment (opens in a new tab)

  19. An investigation into constructed wetlands for domestic greywater treatment and reuse in Ontario

    … treatment systems that can meet reclaimed water quality standards. The purpose of this thesis is to develop a horizontal subsurface flow wetland design that can be sited in a greenhouse, to document the initial performance of the design treating real greywater, to determine the effect of plants, …

    guelph Repository record for An investigation into constructed wetlands for domestic greywater treatment and reuse in Ontario (opens in a new tab)

Page 1 of 14