Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 33 for “"Effluent suspended solids"”

  1. Evaluation of Factors Responsible for High Effluent Suspended Solids Events in the Kuwahee Wastewater Treatment Plant

    <p>The potential factors causing high effluent suspended solids (ESS) in Kuwahee Wastewater Treatment Plant (WWTP) are studied in order to properly identify the reason or reasons that might lead to focus future studies in proper remedial actions in the facility. In this document an analysis …

    ut-knoxville Repository record for Evaluation of Factors Responsible for High Effluent Suspended Solids Events in the Kuwahee Wastewater Treatment Plant (opens in a new tab)

  2. The Use of Enlarged Feed Wells as Flocculator Units in Activated Sludge Secondary Clarifiers

    The quality of the effluent from activated sludge wastewater treatment plants is highly dependent on the performance of the final clarifier. The final clarifier performs solids/liquids separation through sedimentation. The standard design criteria (overflow rate and detention time) must be selected …

    ucf Repository record for The Use of Enlarged Feed Wells as Flocculator Units in Activated Sludge Secondary Clarifiers (opens in a new tab)

  3. An investigation of the effects of the addition of powdered activated carbon to the activated sludge of cellulose acetate manufacturing wastewater

    … at a temperature of 18°C and a biological solids retention times of fourteen days. The addition of PAC also improved the sludge settleability but this resulted in higher effluent suspended solids concentration because zone settling Velocity was the primary factor affecting effluent …

    vt Repository record for An investigation of the effects of the addition of powdered activated carbon to the activated sludge of cellulose acetate manufacturing wastewater (opens in a new tab)

  4. The Effect of Detention Period on the Clarification Efficiency of Nitrified Activated Sludge

    … due to the biochemical oxygen demand exerted by solids lost in the clarifier effluent. Detention period is one factor which influences clarification performance and thus is of interest to the designer engineer. Also of interest is the relationship between detention period and rising sludge …

    ucf Repository record for The Effect of Detention Period on the Clarification Efficiency of Nitrified Activated Sludge (opens in a new tab)

  5. Dynamics and Control of Solids-Liquid Separation in the Activated Sludge Process

    … clarification and thickening functions of the solids-liquid separator. This also included the development of a hydraulic model capable of predicting flow transients through the treatment plant and a solids model to predict MLSS concentrations in the reactors for arbitrary hydraulic forcings. …

    rice Repository record for Dynamics and Control of Solids-Liquid Separation in the Activated Sludge Process (opens in a new tab)

  6. The Effect of Recycle Control on Activated Sludge Clarification Efficiency

    … adverse effects on the clarifier during peak solids loading situations. Although this control action is directed at the thickening function, there has been speculation that the elevated recycle rates may be responsible for an increased effluent solids concentration. To evaluate the …

    ucf Repository record for The Effect of Recycle Control on Activated Sludge Clarification Efficiency (opens in a new tab)

  7. Dynamic Real Time Control of the Activated Sludge Process Using Step Feed

    … feed activated sludge process for control of effluent quality. Computer simulation and pilot studies were used to develop a process control strategy involving the Specific Oxygen Utilization Rate (SCOUR). This control was applied using a real-time minicomputer system. Comparisons were made to …

    mcmaster Repository record for Dynamic Real Time Control of the Activated Sludge Process Using Step Feed (opens in a new tab)

  8. Combined treatment of landfill leachate and domestic sewage

    … properties of the biomass, as reflected by the effluent suspended solids and SVI, improved as the sludge age was increased from 5 days to 20 days. However, due to endogenous respiration, cell lysis occurred in all the systems during the 20-day SRT and this caused the average effluent COD to …

    ubc Repository record for Combined treatment of landfill leachate and domestic sewage (opens in a new tab)

  9. Design parameters for filter capacity

    … breakthrough curves. In the two equations, the solids retention characteristics were described by the filter capacity, (sigma)(,u), and the attachment coefficient, K, and these parameters can easily be obtained by fitting a straight line to data obtained from pilot plant tests;In the filtration …

    iastate Repository record for Design parameters for filter capacity (opens in a new tab)

  10. The Effects of Dissolved Oxygen Concentration and Biological Solids Retention Time on Activated Sludge Treatment Performance

    … the effects of DO concentration and biological solids retention time (BSRT) on treatment performance using the activated sludge process. The four reactors, operating at BSRTs of 20, 10, 5, and 2 days, were fed settled municipal wastewater collected from the Kuwahee wastewater treatment plant in …

    ut-knoxville Repository record for The Effects of Dissolved Oxygen Concentration and Biological Solids Retention Time on Activated Sludge Treatment Performance (opens in a new tab)

  11. Impacts of Operating Parameters on Extracellular Polymeric Substances Production in a High Rate Activated Sludge System with Low Solids Retention Times

    … The present study evaluated the influence of the solids retention time (SRT), dissolved oxygen (DO) concentration, and production of extracellular polymeric substances (EPS) on bio-flocculation and subsequent carbon capture using a pilot-scale A-stage process. A mixed liquor suspended solids …

    odu Repository record for Impacts of Operating Parameters on Extracellular Polymeric Substances Production in a High Rate Activated Sludge System with Low Solids Retention Times (opens in a new tab)

  12. Cost Effective Design of the Activated Sludge Wastewater Treatment System

    … subject to constraints on the following: effluent suspended solids effluent substrate concentration underflow solids concentration maximum and minimum mixed liquor suspended solids concentration maximum and minimum values for settling basin depth Recognizing the importance of the final …

    ucf Repository record for Cost Effective Design of the Activated Sludge Wastewater Treatment System (opens in a new tab)

  13. Development and assessment of a membrane bioreactor for wastewater treatment

    … biological treatment process to treat dairy effluent. Another unit similar to the process above was also set up but with a gravity settling tank replacing the membrane unit. Kinetic studies were done on both processes and their results compared. Effluent characteristics of both processes were …

    dut Repository record for Development and assessment of a membrane bioreactor for wastewater treatment (opens in a new tab)

  14. Secondary Clarifier Modeling: A Multi-Process Approach

    … atmospheric conditions and the total dissolved solids concentration. A Quasi-3D (Q3D) clarifier model has been developed to include the following factors: axisymmetric hydrodynamics (including the swirl component), five types of settling (nonsettleable particles, unflocculated discrete settling, …

    uno Repository record for Secondary Clarifier Modeling: A Multi-Process Approach (opens in a new tab)

  15. Mathematical modelling of clean water treatment works

    … surrogate models that can be used to predict the effluent suspended solids concentration, for a given number of independent variables. This approach can provide valuable guidance in clean water treatment process design and operation, thus providing a tool to achieve better day-to-day performance …

    ucl Repository record for Mathematical modelling of clean water treatment works (opens in a new tab)

  16. Fundamentals of the static granular bed reactor

    … anaerobic system. High organic removal, low effluent suspended solids (TSS), and high methane content in the off gas were consistently obtained with all SGBRs operated. Two SGBRs treating non-fat dry milk, or synthetic wastewater, were operated continuously for more than four years at …

    iastate Repository record for Fundamentals of the static granular bed reactor (opens in a new tab)

  17. Effects of copper on nitrification and denitrification of leachate from an abandoned landfill

    … inhibit denitrification, but did cause elevated effluent suspended solids concentrations. An additional treatment step would be needed for reliable treatment of the leachate. Copper additions caused inhibition of both nitrification and denitrification. The degree of nitrification and …

    vt Repository record for Effects of copper on nitrification and denitrification of leachate from an abandoned landfill (opens in a new tab)

  18. High rate wastewater treatment using aerobic upflow sludge blanket (AUSB) with external oxygenation

    … high upflow velocity through the reactor, the effluent suspended solids was mostly below 70 mg/L, which could be polished further for SS removal without using a conventional secondary clarifier. The AUSB sludge showed a high specific oxygen uptake rate (SOUR) of up to 180-250 mg O<sub>2</sub>/g …

    hkust Repository record for High rate wastewater treatment using aerobic upflow sludge blanket (AUSB) with external oxygenation (opens in a new tab)

Page 1 of 2