Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 29 for “"Electric arcs"”

  1. Theoretical, numerical and experimental study of DC and AC electric arcs

    … La simulation numérique a été faite pour des arcs en régimes DC, pulsé et AC à des pressions atmosphériques et inférieures. Les principales caractéristiques de l’arc ont été analysées et discutées. Les résultats obtenus ont été comparés avec les résultats expérimentaux et ont montré un bon …

    star-france Repository record for Theoretical, numerical and experimental study of DC and AC electric arcs (opens in a new tab)

  2. The initiation of electric arcs and the possible impact in industrial environments

    Advancing knowledge and understanding of electrical arc flash and arc blast hazards through experimentation, modelling and analysis is the main goal of the present thesis. To achieve this, initially, significant work has been carried out to analyse existing data on arc flash hazards and mitigation …

    strathclyde Repository record for The initiation of electric arcs and the possible impact in industrial environments (opens in a new tab)

  3. The initiation of electric arcs and the possible impact in industrial environments

    Advancing knowledge and understanding of electrical arc flash and arc blast hazards through experimentation, modelling and analysis is the main goal of the present thesis. To achieve this, initially, significant work has been carried out to analyse existing data on arc flash hazards and mitigation …

    greece Repository record for The initiation of electric arcs and the possible impact in industrial environments (opens in a new tab)

  4. Investigations into practical closed-loop arc control systems

    … of literature on the high velocity behaviour of electric arcs in magnetic fields. This has been used together with original experiments carried out by the author, to produce a mathematical model for a low velocity low power arc. A control system has been developed using an original arc velocity …

    aston Repository record for Investigations into practical closed-loop arc control systems (opens in a new tab)

  5. Modelling and analysis of electric arc loads using harmonic domain techniques

    … has been reported that as much as 12% of global electricity production goes into producing artificial light using arc discharge lamps and that global annual production of these lamps may be as much as 1.2 billion units. In the liquid steel production industry, one metric tone of steel demands, on …

    glasgow Repository record for Modelling and analysis of electric arc loads using harmonic domain techniques (opens in a new tab)

  6. The Photography and Identification of the Secondary Spectrum of Helium

    … introduced; in spaces between the electrodes of electric arcs; in spark discharges; and In discharge tubes.

    marquette Repository record for The Photography and Identification of the Secondary Spectrum of Helium (opens in a new tab)

  7. Arc Fault Detection in DC Photovoltaic Systems

    Arc faults have always been a concern for electrical systems as they can cause fires, personnel shock hazard, and system failure. In photovoltaic (PV) systems, a large number of electrical connectors and long wire runs are expected. Combined with the high DC voltage, deterioration of the wire …

    tamu Repository record for Arc Fault Detection in DC Photovoltaic Systems (opens in a new tab)

  8. Investigating DC circuit breaker service life

    … spike mitigation techniques aimed at reducing electric arcs during switching operations. Unlike AC systems, DC lacks a natural zero-crossing which results in large transient voltages that accelerate switch wear and reduce service life. A low-cost low-complexity RC circuit was designed using …

    uoit Repository record for Investigating DC circuit breaker service life (opens in a new tab)

  9. Series Dc Arc Characterization, Prevention & Detection inAircraft Systems

    … systems, dc bus voltages are expected to rise aselectrication efforts push power demands higher. Higher bus voltages improve systemeffciency and reduce the weight of the cabling system. Despite these advantages,electric arcs become a signicant threat in aircraft when the higher voltage is …

    ohiolink Repository record for Series Dc Arc Characterization, Prevention & Detection inAircraft Systems (opens in a new tab)

  10. Mathematical modelling of electrical, thermal, and chemical processes occurring within a silicon furnace

    … endothermic chemical reactions provided by an electric current. The interacting physical processes occurring in SAFs are tightly coupled, and vary over a range of timescales. As a result, SAF modelling efforts have generally neglected to include many of the chemical, thermal, and electrical …

    oxford Repository record for Mathematical modelling of electrical, thermal, and chemical processes occurring within a silicon furnace (opens in a new tab)

  11. Evaluation of the need for having neutral sections in Banverkets catenary system

    … de-energized. They reduce the risks of creating electric arcs and the damage on section points. However they cost a lot of money to build and the heavy section isolator that are used in some cases might damage the pantograph. Neutral sections can be removed in some places, where the energizing is …

    chalmers Repository record for Evaluation of the need for having neutral sections in Banverkets catenary system (opens in a new tab)

  12. Pre-Study of Arc Extinguishing Techniques for a 4-Pole 1500 VDC Contactor

    … of current. When the contacts are separated an electric arc occurs between them which has to be extinguished in some way for the current to be broken. This makes DC breaking extra difficult and special features need to be implemented in order to extinguish the arc and break the current ow. High …

    chalmers Repository record for Pre-Study of Arc Extinguishing Techniques for a 4-Pole 1500 VDC Contactor (opens in a new tab)

  13. ON-LINE DETECTION AND LOCATION OF LOW-LEVEL ARCING FAULTS IN METAL-CLAD ELECTRICAL EQUIPMENT

    Modern metal-clad electrical equipment are built with tight insulation tolerances and are consequently subjected to severe electrical and thermal stresses. Insulation failure as a result of higher electrical and thermal stresses leads to arcing faults. Large numbers of equipment fire and burndown …

    sask Repository record for ON-LINE DETECTION AND LOCATION OF LOW-LEVEL ARCING FAULTS IN METAL-CLAD ELECTRICAL EQUIPMENT (opens in a new tab)

  14. ESTUDIO METALOGRÁFICO DE LOS EFECTOS DE ARCOS ELÉCTRICOS PRIMARIOS Y SECUNDARIOS SOBRE CABLEADO DE COBRE EN EL INTERIOR DE DIFERENTES ATMÓSFERAS. APLICACIÓN A LA INVESTIGACIÓN DE INCENDIOS Y COMPARACIÓN DE RESULTADOS CON INCENDIOS REALES

    … of fires is particularly important to study electrical conductors. A detailed analysis of them provides evidence or indications regarding the cause of the sinister. In this current thesis are studied typical electrical conductors, which have been subjected to different environmental …

    upv Repository record for ESTUDIO METALOGRÁFICO DE LOS EFECTOS DE ARCOS ELÉCTRICOS PRIMARIOS Y SECUNDARIOS SOBRE CABLEADO DE COBRE EN EL INTERIOR DE DIFERENTES ATMÓSFERAS. APLICACIÓN A LA INVESTIGACIÓN DE INCENDIOS Y COMPARACIÓN DE RESULTADOS CON INCENDIOS REALES (opens in a new tab)

  15. A study of the influence of an external magnetic field on electric arc behaviour in low-voltage dc switching

    The rapid growth of battery-powered electric vehicles, dc renewable-energy sources (e.g.,photovoltaic systems), and associated dc energy storage devices has stimulated increasing interest in low-voltage (less than 100 V) dc switching for isolation and protection. Interrupting a dc circuit is more …

    soton Repository record for A study of the influence of an external magnetic field on electric arc behaviour in low-voltage dc switching (opens in a new tab)

  16. Conductive material within Temperature Management

    … of current. When the contacts are separated an electric arc occurs between them which has to be extinguished in some way for the current to be broken. This makes DC breaking extra difficult and special features need to be implemented in order to extinguish the arc and break the current ow. High …

    chalmers Repository record for Conductive material within Temperature Management (opens in a new tab)

  17. Reconnaissance d'arcs de défaut dans les aéronefs par apprentissage artificiel

    … d'un contact par exemple. Dans le cas d'arcs indésirables liés à des défauts, détecter leur présence le plus rapidement possible afin de les couper constitue donc un enjeu majeur. L'énergie et la capacité destructrice des arcs sont directement liées à la puissance du réseau de …

    star-france Repository record for Reconnaissance d'arcs de défaut dans les aéronefs par apprentissage artificiel (opens in a new tab)

Page 1 of 2