Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 18 of 18 for “"Electrical Low Pressure Impactor"”

  1. Combination of mass loss cone, Fourier transforminfrared spectroscopy and electrical low pressure impactor to extend fire behaviour characterization of materials

    L’incendie reste un des sujets redoutés par les industries, les services et autres moyens de production. Ce phénomène par définition incontrôlé dans le temps et dans l’espace est souvent responsable de perte de vies et de biens. Deux types d’agression peuvent être répertoriés en cas d’incendie …

    star-france Repository record for Combination of mass loss cone, Fourier transforminfrared spectroscopy and electrical low pressure impactor to extend fire behaviour characterization of materials (opens in a new tab)

  2. Détermination expérimentale de la vitesse de dépôt sec des aérosols submicroniques en milieu naturel : influence de la granulométrie, des paramètres micrométéorologiques et du couvert

    … en utilisant un impacteur à basse pression (Electrical Low Pressure Impactor, ELPI, DEKATI), à travers des mesures expérimentales in situ. L’originalité de la méthode est le calcul des flux de dépôt par corrélation turbulente. Les vitesses de dépôt sec ont été obtenues pour des aérosols …

    star-france Repository record for Détermination expérimentale de la vitesse de dépôt sec des aérosols submicroniques en milieu naturel : influence de la granulométrie, des paramètres micrométéorologiques et du couvert (opens in a new tab)

  3. Inertial Aerosol Deposition in Neonatal Infant Nasal Airways

    … particles in these models was measured using an electrical low pressure impactor (ELPI). The aerosol entering the nasal replica is characterized with the ELPI by sampling through a blank line. The reduction in concentration of aerosol after passing through the nasal replica is the deposited …

    alberta Repository record for Inertial Aerosol Deposition in Neonatal Infant Nasal Airways (opens in a new tab)

  4. INFLUENCE OF ELECTROSTATIC CHARGE UPON THE DEPOSITION BEHAVIOR OF PHARMACEUTICAL AEROSOLS WITHIN CASCADE IMPACTORS

    Cascade impactors, routinely used for in vitro particle size characterization of pharmaceutical aerosols, are calibrated using dilute, charge-neutralized, monodisperse aerosols. But pharmaceutical aerosols are known to generate concentrated, inherently charged, polydisperse aerosol clouds. A …

    vcu Repository record for INFLUENCE OF ELECTROSTATIC CHARGE UPON THE DEPOSITION BEHAVIOR OF PHARMACEUTICAL AEROSOLS WITHIN CASCADE IMPACTORS (opens in a new tab)

  5. CONTROL OF DIESEL PARTICULATE AND GASEOUS EMISSIONS USING A SINGLE-STAGE TUBULAR WET ELECTROSTATIC PRECIPITATOR

    … measured. A nonroad diesel generator utilizing a low sulfur diesel fuel (500 ppmw) operating at varying load conditions was used as a stationary diesel emission source. The DPM mass analysis was conducted by means of isokinetic sampling and the DPM mass concentration was determined by a …

    ohiolink Repository record for CONTROL OF DIESEL PARTICULATE AND GASEOUS EMISSIONS USING A SINGLE-STAGE TUBULAR WET ELECTROSTATIC PRECIPITATOR (opens in a new tab)

  6. Molecular Responses of Arabidopsis thaliana to Environmental Metal Stressors: Root Cadmium Exposure and Metallic Ultra-Fine Particles from Traffic

    … state-of-the-art analytical methods, such as electrical low-pressure impactor (ELPI+) and single particle ICP-MS (spICP-MS). As a proof of concept and to gain first insights into the physiological processes triggered by metallic UFP exposure, transcriptomic data with A. thaliana were …

    bayreuth Repository record for Molecular Responses of Arabidopsis thaliana to Environmental Metal Stressors: Root Cadmium Exposure and Metallic Ultra-Fine Particles from Traffic (opens in a new tab)

  7. Direct injection gasoline engine particulate emissions

    … soot sensor; condensation particle counter and electrical low pressure impactor. To address the second question, a differential mobility spectrometer is applied to quantify the PM emissions from a number of direct injection gasoline engines, together with investigation of their dependence on …

    oxford Repository record for Direct injection gasoline engine particulate emissions (opens in a new tab)

  8. Particulate wear debris of coated lightweight disc brakes

    … have put automotive companies under tremendous pressure to improve vehicle fuel economy and reduce the carbon dioxide emissions. The use of lightweight disc brake rotors is one of the solutions to meet this legislative requirement. Due to significant reductions in exhaust emissions, the …

    whiterose Repository record for Particulate wear debris of coated lightweight disc brakes (opens in a new tab)

  9. Diesel Exhaust System Influences on Transient Particulate Emissions and Particle Size Distribution

    … with fast acceleration, reaching one of the following target operation conditions: Idle, 1500rpm - 15kW, 2250rpm - 15kW, 2250rpm-35kW and 3500rpm - 15kW. Two preconditioning procedures were designed to provide repeatable cold start tests. These consisted of a) Idle operation for 4 hours the day …

    whiterose Repository record for Diesel Exhaust System Influences on Transient Particulate Emissions and Particle Size Distribution (opens in a new tab)

  10. Measurement of Size-specific Filtration Efficiency and Pressure Drop through Face Masks

    … this thesis was to examine the effects of the following two common usage conditions which may influence parameters that are critical to filtration: 1) moist heat incubation decontamination of respirators for reuse and 2) lower face velocity from school-aged children breathing through woven and …

    alberta Repository record for Measurement of Size-specific Filtration Efficiency and Pressure Drop through Face Masks (opens in a new tab)

  11. Development of a chromium-free consumable for joining stainless steel

    … in the United States and abroad are decreasing allowable exposure levels of hexavalent chromium to welding related personnel. A 2006 OSHA ruling reduced the permissible exposure limit of airborne hexavalent chromium from 52 to 5 micrograms/cubic meter. Achieving the new level may not be practical …

    ohiolink Repository record for Development of a chromium-free consumable for joining stainless steel (opens in a new tab)

  12. Aerosol size distribution and size resolved composition in urban areas of Colombia

    … airborne aerosols were investigated utilizing impactors cascades to measure the size of inhale particles. The particle number concentration and particle number size distribution were measured in the size range from 17 nm and 10 mm using an Electrical Low-Pressure Impactor (ELPI+). Also, was …

    un-colombia Repository record for Aerosol size distribution and size resolved composition in urban areas of Colombia (opens in a new tab)

  13. Measurements and analysis of vertical distribution, surface fluxes, and chemical composition of atmospheric aerosol in two Italian Alpine valleys

    … scavenging was not effective if accompanied by low wind and friction velocities along with a significant increase in emission sources. Other aerosol sources, such as secondary particulate matter formation in the atmosphere, manure, fertilizers, or lithospheric erosion, were instead appointed in …

    trento Repository record for Measurements and analysis of vertical distribution, surface fluxes, and chemical composition of atmospheric aerosol in two Italian Alpine valleys (opens in a new tab)

  14. Media and Devices for Management of Airborne Contaminants

    … devices are highly efficient over a range of flow rates and temperatures; however, some system conditions result in a decrease in efficiency with increasing temperature in a manner not predicted by theory. Experiments were performed on a bench system that introduced atomized oil particles into …

    umn Repository record for Media and Devices for Management of Airborne Contaminants (opens in a new tab)

  15. Media and Devices for Management of Airborne Contaminants

    … devices are highly efficient over a range of flow rates and temperatures; however, some system conditions result in a decrease in efficiency with increasing temperature in a manner not predicted by theory. Experiments were performed on a bench system that introduced atomized oil particles into …

    umn Repository record for Media and Devices for Management of Airborne Contaminants (opens in a new tab)

  16. Media and Devices for Management of Airborne Contaminants

    … devices are highly efficient over a range of flow rates and temperatures; however, some system conditions result in a decrease in efficiency with increasing temperature in a manner not predicted by theory. Experiments were performed on a bench system that introduced atomized oil particles into …

    umn Repository record for Media and Devices for Management of Airborne Contaminants (opens in a new tab)

  17. Electrical Behavior of Non-Aqueous Formulations: Role of Electrostatic Interactions in Pressurized Metered Dose Inhalers (pMDIs)

    … charging mechanisms inside the pMDI formulation.Electrical resistivity and zeta potential measurements confirmed the presence of charged species within HFA based solutions and suspensions although the nature of these species remains unknown. These measurements were influenced by the cosolvent …

    vcu Repository record for Electrical Behavior of Non-Aqueous Formulations: Role of Electrostatic Interactions in Pressurized Metered Dose Inhalers (pMDIs) (opens in a new tab)

  18. Ανάπτυξη μεθοδολογίας για την εκτίμηση της τοξικότητας σωματιδιακών εκπομπών από οχήματα

    … (DPF) to study the toxicity of emissions at the low emission levels imposed by the DPF (D Euro 4+). In this way, these five configurations promised particulate emissions with significant variability in their physicochemical characteristics. Theoretically, this diversity in particle …

    greece Repository record for Ανάπτυξη μεθοδολογίας για την εκτίμηση της τοξικότητας σωματιδιακών εκπομπών από οχήματα (opens in a new tab)