Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 18 of 18 for “"Electrical cable"”
-
An Analysis of Thermally Induced Arcing Failure of Electrical Cable
… 14/2 American wire gauge (AWG) with ground cable due to external heat was examined. This type of cable was selected due to its widespread use in residential building wiring. This research is motivated by the fact that currently there are no widely accepted methods or models used to predict …
-
Modeling of Electrical Cable Failure in a Dynamic Assessment of Fire Risk
… fires is the need to determine the likelihood of electrical cable failure which can lead to the loss of the ability to control or spurious actuation of equipment that is required for safe shutdown. A number of plants are now transitioning from their deterministic fire protection programs to a …
-
Multi-dimensional modeling of thermal conditions and pyrolysis dynamics in electrical cable fire
Electrical cables present significant fire hazards across residential, industrial, and aeronautical settings. While numerical modeling offers a cost-effective way to design safer cables and predict their fire performance, its predictive capability depends heavily on the level of model uncertainty. …
-
An instrumented controlled-atmosphere cone calorimeter to characterize electrical cable behavior in depleted fires
Les câbles électriques constituent la charge calorifique la plus abondante dans les centrales nucléaires et l'incendie est la source d'agression interne ayant la plus grande occurrence (un départ de feu par tranche et par an en France). Le risque incendie est caractérisé par deux vecteurs : la …
-
Evaluation of critical nuclear power plant electrical cable response to severe thermal fire conditions
The failure of electrical cables exposed to severe thermal fire conditions are a safety concern for operating commercial nuclear power plants (NPPs). The Nuclear Regulatory Commission (NRC) has promoted the use of risk-informed and performance-based methods for fire protection which resulted in a …
-
Analysis of metallic coatings based in zinc-aluminium-magnesium alloys, in terms of performance and long-term corrosion. Case study: Electrical cable trays selection in project design
[ES] En los últimos años, se han desarrollado numerosos tipos de recubrimientos superficiales frente a la corrosión basados especialmente en aleaciones de cinc-aluminio-magnesio (conocidas como aleaciones "ZM"), como alternativas a los recubrimientos tradicionales basados en cinc (conocidos como …
-
UNMANNED GROUND VEHICLE (UGV) DOCKING, CONNECTION, AND CABLING FOR ELECTRICAL POWER TRANSMISSION IN AUTONOMOUS MOBILE MICROGRIDS
Autonomous Mobile Microgrids provide electrical power to loads in environments where humans either can not, or would prefer not to, perform the task of positioning and connecting the power grid equipment. The contributions of this work compose an architecture for electrical power transmission by …
-
APPLICATIONS OF ROBOT OPERATING SYSTEM (ROS) TO MOBILE MICROGRID FORMATION OUTDOORS
… UGV, and design and installation of a active electrical cable delivery system. Results begin with representation of the capabilities of each of these contributions. Finally, outdoor demonstration results are presented and a code appendix is included.
-
Torsion testing for characterizing the plastic behavior in metals: determination of material flow stress for FEM-based design and optimization of metal forming processes
… and optimization of the wire drawing process for electrical cable production. A theoretical multi-pass drawing model is developed, considering the entire process and focusing on the relationship between drawing and back-stresses. The model is implemented by incorporating the material’s plastic …
-
An analysis of the degree of implementation of total quality and technology management principles to enhance the competitive status of a cable manufacturing company
The cable manufacturing industry may not be well known to some people, yet people’s very lives depend on products and services it produces. Today people live in a highly technological or digital world where most of the technology used by society has at least one electrical cable in it or is …
-
Modelling and Analysis of Close Contact Ultrasonic Power Transfer Systems with Metal Barriers
Traditional methods of powering electrical loads across sealed metallic containers require physical penetration of the metallic body to feed an electrical cable through it, thus reducing the structural integrity of the container. Consequently, wireless power transfer technologies are employed to …
-
Imitation Learning in Robotic Manipulation Using Diffusion Models
… designed to teach the robot to interact with an electrical cable, simulating a current measurement operation, an application with strong practical relevance for industry. The training procedures are also detailed, including data preprocessing and organization strategies, as well as the metrics …
-
A finite element calculation method for the heat transfer effects on the current-carrying capacity of underground electrical cables
… the global heat dissipation around underground electrical cable installations, used in electricity transmission and distribution. A detailed numerical solution of the complex heat transfer present; conduction, free convection and radiation, with unknown boundary values at the air-solid …
-
Dietary exposure of 1,2-dibromo-4-(1,2-dibromoethyl)cyclohexane to juvenile brown trout (Salmo trutta): bioaccumulation parameters and effects on circulating plasma sex hormones
… foam, adhesive in fabric and vinyl lamination, electrical cable coatings and construction materials. The technical formulation contains two diastereoisomers, α- and β-, which are present in equimolar amounts. Under elevated temperatures two other isomers, γ- and δ-, can be formed. The recent …
-
Evaluation of Biomass and Coal Briquettes for a Spreader Stoker Boiler Using an Experimental Furnace - Modeling and Test
… such as reduced motor life, connector/cable failure, and VFD tripping. To better understand the behavior of electric motors in diverse environ- ments, experimental testing has been conducted on two different 230/460 V 3-phase AC brushless motors at unloaded and loaded conditions. The …
-
Development of fire sprinkler system design for buildings with exposed timber surfaces
… of screw fixings used to suspend mechanical and electrical (M&E) services from CLT ceilings, including sprinkler systems, at ambient (pre-fire), under fire and post-fire conditions. Pull-out tests were conducted to evaluate load capacity in non-fire conditions, and these measurements were used as …
-
Discriminating and Localizing Thermal Aging in Low Voltage Polymeric Cables using Non-Destructive Electrical Diagnostics
… attention is being paid to the condition of LV electrical cable systems in nuclear power plants (NPPs), given industry and governmental efforts to extend the operational life of numerous existing NPPs well beyond their initial 40-year design life / license period. Thermal degradation is a key …
-
Crosslinking of ethylene copolymers from epoxy chemistry
La plupart des couches d'isolation de câbles pour la moyenne tension "MV" et haute tension "HV" sont fabriquées en polyéthylène réticulé (XLPE) par voie peroxyde. L'impact des sous-produits de réaction sur les propriétés et la nécessité d'une étape de dégazage au cours du processus sont les …