Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 87 for “"Electrical pulses"”.
-
Detection of electrical pulses during water tree growth in polyethylene
… tree initiation, growth, and transition to an electrical tree. The experimental techniques included phase resolution, bandwidth and time constant adjustment, and several digital signal processing (DSP) techniques. The principle is to detect image currents in two electrodes, via two very low …
-
The Correlation Between Electrical Pulses and Light Flashes in a Proportional Counter.
… one primary ion pair is sufficient to cause an electrical discharge that expands to fill the whole volume of the Geiger tube. In pulse ion chambers, on the other hand, the electric field is not high enough to cause any further ionization, thus only the charge separated by the radiation will be …
-
Utilization of reflections from transmission line elements to produce positive electrical pulses of 0.006 microseconds duration at high repetition rates
… Agriculture and Applied Science. Department of Electrical Engineering, 1950
-
Reparo induzido pela técnica de emissão de pulsos elétricos (electropulsing) na liga AA5083 utilizada da indústria do petróleo
The electrical pulse processing technique (EPT) on a material can be considered an effective alternative for promoting self-repair mechanisms. This technology can favor the prevention of nucleation, coalescence and propagation of microstructural defects in metallic materials used in several …
-
Circuit Modules for CMOS High-Power Short Pulse Generators
High-power short electrical pulses are important for high-performance functionality integration, such as the development of microelectromechanical/nanoelectromechanical systems (MEMS/NEMS), system on chip (SoC) and lab on chip (LoC). Many of these applications need high-power (low impedance load) …
-
The Effects of Electrical Muscle Stimulation on Strength Gains in Healthy Subjects
… the purpose of this study to test the effects of electrical muscle stimulation in developing strength. An additional purpose was to determine if specificity of training occurs with electrical muscle stimulation, in that a slow electrical pulse rate would be more effective in developing strength at …
-
Scaling and Performance of a Device for Fluidized Bed Entrainment Reduction
… determined the particle mass flux by counting electrical pulses produced when particles collided with a metal sensor placed in the flow stream. Air velocity was measured with a rugged hot film anemometer.
-
Single- and entangled-photon emission from strain tunable quantum dots devices
… within a light-emitting diode (LED) to achieve electrically driven sources. Therefore, one would expect a full-fledged optoelectronic quantum network that is running on macroscopically separated, QD-based single- and entangled-photon devices. An all-electrically operated wavelength-tunable on …
-
A pulse analyzer
… is a device for determining the number of electrical pulses within a given size, or voltage range which may be produced by any given source. For example, it may be used to determine the number of pulses between 0.1000 and 0.1005 volts, which may be produced in any given interval of time. …
-
Brownian Dynamics Simulation Studies of Ion Throughput During Cellular Electroporation
… understood, it will become possible to design electrical pulses and tailor waveforms for maximizing the throughput of DNA, drugs, and gene materials.
-
Odlat kött
… starch microspheres. Furthermore, the effect of electrical pulses, with the purpose of enlarging the muscle cells, is examined. The cells are grown in regular cell cultivation dishes modified with electrodes of platinum connected to a pulse generator. The experimental results show that it is …
-
Magnetic field diffusion in metallic and superconducting cylinders /
… field, temperature and nanosecond duration electrical pulses were studied in thin YBaCuO films deposited on Al2¬O¬¬3 with CeO¬2 sublayer; properties of type II superconducting armatures were investigated for coil launcher application. It was obtained that the magnetic field is noticeably …
-
Stable nonvolatile phase modulation with antimony-based phase shifter on a broadband silicon nitride platform
… ±1.9 dB. Switching is achieved using controlled electrical pulses of 13 V for 300 µs for crystallisation and 30 V for 1.5 µs for amorphisation, resulting in a phase shift of approximately 0.43π over a PCM interaction length of 20 µm. These results confirm the robustness and effectiveness of the …
-
Non-invasive internal pattern extraction of integrated circuits using electrostatic force microscopy
… A heterodyne technique which utilizes short electrical pulses for sampling is implemented to extract an arbitrary periodic digital pattern. This thesis also evaluates three narrow pulse generation techniques. An Integrated Circuit version of the Non-Linear Transmission Line (NLTL) was …
-
Estudo do efeito de pulsos elétricos no auto-reparo da liga pré-deformada AA7075 (Al-Zn-Mg-Cu): comportamento mecânico e evolução microestrutural
… for metallic materials, processing by electrical pulses, EPT (Electropulsing Treatment) is a new approach to self-healing that is increasingly important in technology. Applying a controlled current of sufficiently high density but with a low-temperature rise generates an electron flow …
-
Algorithms for inhibition and desynchronization of neural systems /
… of neural activity is oscillations. Through the electrical interaction, neurons tend to synchronize their rhythms and approach a coherent behaviour. On the one hand synchronous neural behaviour relates with such crucial brain functions as vision and memory, while on other hand pathological …
-
Neuroninių sistemų slopinimo ir desinchronizavimo algoritmai /
… of neural activity is oscillations. Through the electrical interaction, neurons tend to synchronize their rhythms and approach a coherent behaviour. On the one hand synchronous neural behaviour relates with such crucial brain functions as vision and memory, while on other hand pathological …
-
Erythrosensors Cellular Characterization
… tonicity. Electroporation relies on controlled electrical pulses that results in reversible pores formation to allow cargo entrance. As part of the cellular characterization of loaded erythrocytes, size and hemoglobin content was evaluated. Cell recovery and fluorescence per cell measurements …
-
DESIGN OF A TIME-AMPLIFIED, STOCHASTIC PHASE INTERPOLATION TIME-TO-DIGITAL-CONVERTER FOR BIOMEDICAL IMAGING APPLICATIONS
… the two input signals. In SPAD-imagers, the electrical pulses triggered by incident photons are measured against the reference clock to extract time-of flight (ToF) data. The performance of TDC is directly related to the temporal performance of the SPAD-imagers in biomedical imaging systems, …
-
Design and Manufacture of a High-Frequency Annular Array Ultrasound System for Medical Imaging
… for larger arrays. The pulser produces monocycle electrical pulses with centre frequencies that could be adjusted from 10-50 MHz and with amplitudes up to 90 Vpp. The annular array transducer has 12 equal area elements and a total active aperture of 6 mm. The transducer array produced pulses with …
Page 1 of 5