Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 17 of 17 for “"Electrical resistance heating"”.
-
Laboratory study evaluating electrical resistance heating of pooled trichloroethylene
… (TCE) in a saturated groundwater system using electrical resistance heating (ERH). Two experiments were conducted using a two-dimensional polycarbonate test cell, the first consisting of a single pool of TCE perched above a capillary barrier, the second consisting of two pools of TCE each …
-
Electrical Resistance Heating of Groundwater Impacted by Chlorinated Solvents in Heterogeneous Sand
… received increasing attention in recent years. Electrical resistance heating (ERH) is a commonly applied thermal technology in the industry. ERH applications are used at heterogeneous sites, where permeability contrasts can significantly impact the heating process along with the movement of …
-
Gas Production and Mass Transfer During Electrical Resistance Heating of Clay Lenses
… of remediation in clay lenses in sand by electrical resistance heating (ERH). Clay lenses are areas of accumulation for dense non-aqueous phase liquid (DNAPL) and are difficult to remediate. Experiments were performed in a two-dimensional, saturated porous medium comprising of an …
-
Impact of Low Temperature Electrical Resistance Heating on Subsurface Flow and Mass Transport
… flow and mass transport, as a result of electrical resistance heating (ERH). Low temperature ERH was simulated using a newly developed two-dimensional, electro-thermal, flow and transport model (ETM). To capture the non-isothermal processes in the subsurface during low temperature ERH, …
-
Gas Dynamics during Bench-Scale Electrical Resistance Heating of Water, TCE and Dissolved CO2
… and transport mechanisms during bench-scale electrical resistance heating (ERH) experiments were examined in this study using a quantitative light transmission visualization method. Processed images during water boiling indicated that gas bubble nucleation, growth and coalescence into a …
-
Comparative Evaluation of Electrical Heating Methods for Oil Sand Reservoirs
… homogeneity. An alternative approach of applying electrical energy, including methods of electric heater, electrical resistance heating and electromagnetic heating, can be used to generate heat in reservoirs that are not suitable for steam injection or to improve the economics of the heavy oil …
-
Organic Vapor Recovery Using Activated Carbon Fiber Cloth and Electrothermal Desorption
… (ED). ED regenerates the adsorbent by efficient electrical resistance heating. A unique aspect of this technology is that adsorbate readily condenses inside the adsorption vessel and is recovered as a pure liquid with only passive cooling during the regeneration of the ACFC. Such feature …
-
Semi-empirical model of convection heat transfer at windows and blinds near floor diffusers for use in building energy modeling
… end, energy flows associated with a specific Heating Ventilation and Air-Conditioning (HVAC) configuration- a floor register near a glass curtain wall with or without Venetian blinds- are analyzed experimentally and partially described with accepted theory. Natural convection at the same …
-
A LABORATORY STUDY ON THE EFFECTS OF DISSOLVED GAS EXSOLUTION ON THE PERFORMANCE OF IN-SITU THERMAL TREATMENT TECHNOLOGIES
… laboratory scale experiments. Laboratory-scale heating experiments were conducted at temperatures above and below the co-boiling temperature using sand-water-NAPL mixtures with and without dissolved carbon dioxide-saturated water. Results indicated extraction of NAPL was possible at temperatures …
-
Clinching of AA7075 Aluminum Sheets
… failed to form a successful joint. A novel electrical resistance heating technique (ERH) to provide ductility to the joined sheets was used to obtain die-less clinched joints in AA7075-T6. ERH technique provides a large range of heating temperatures from room temperature to 270°C for a …
-
Study of Uniaxial Compression Process for AA7075 Aluminum Alloy
… in deformed cubes. The non-isothermal rapid heating of test specimens using electrical resistance heating and subsequent compression of the specimen provided results similar to the isothermal case. However, the electrical resistance method offers a cost-effective process to form smaller high …
-
Recovery of stranded heavy oil by electromagnetic heating
… the formation. The application of low-frequency heating, also known as electrical resistance heating, is limited by water vaporization near the wellbore which breaks the conductive path to the reservoir, and limits the heating rate as well as the resulting production rates. Electromagnetic (EM) …
-
Numerical Modeling of Steam Flushing for Removal of Dense Nonaqueous Phase Liquids
… developments were followed by the advancement of electrical resistance heating (ERH) and thermal conductive heating (TCH). Over the last three decades, a variety of field scale projects and laboratory experiments have been performed using the various types of in situ thermal treatment technologies …
-
Development of integrated food processing technologies based on the application of electric fields: effects on denaturation of milk proteins
… be achieved. The promise of rapid and volumetric heating has called the attention of food industry for the potential use of ohmic heating (OH) in food preservation. OH, also called Joule heating or electrical resistance heating is one of the earliest applications of electricity in food …
-
Glass Melting Using Concentrated Solar Heat
… concentrated solar heat. However, secondary heating was necessary to sustain the flow beyond the focal spot of the beam while avoiding fracture of the crucible due to thermal gradients induced by the beam. Also, the efficiency of this process was very poor (3-4%) and the throughput was very …
-
Contaminant mass transfer during boiling in fractured geologic media
… was removed at a rate 6 times higher than before heating. The nonvolatile bromide concentration, as an indicator of the steam quality, showed a reverse correlation with the volatile 1,2-DCA concentration, indicating that the majority of 1,2-DCA was removed by partitioning to the vapor phase. To …