Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 21 for “"Electrical signatures"”
-
Analysis of electrical signatures in synchronous generators characterized by bearing faults
… generators is proposed based on the analysis of electrical signatures, and its bearing fault detection capability is demonstrated. Experiments with staged bearing faults are conducted to validate the effectiveness of the proposed fault detection method. First, a generator test bed with an in- …
-
Analysis of Ball Bearing Defects in Synchronous Machines using Electrical Measurements
Rolling element bearings are used in most electrical machines, especially for small and medium size applications. Under non-ideal operating conditions, ball bearing condition degrades by fatigue, ambient vibration, misalignment, overloading, contamination, corrosion from water or chemicals, …
-
Marker-Free Isolation and Enrichment of Rare Cell Types Including Tumor Initiating Cells through Contactless Dielectrophoresis
… to manipulate rare cell types based on their electrical signatures using dielectrophoresis (DEP) without having direct contact between the electrodes and the sample, known as contactless dielectrophoresis (cDEP). DEP is the motion of a particle in a suspending medium due to its polarization in …
-
Comparative analysis of electrical and mechanical fault signatures in induction motors
This research deals with the comparison of fault signatures in induction motors. The primary objective is to study and analyze the similarities in the electrical and mechanical fault signatures, and to determine the suitability of the former for effective motor fault detection. Currently, vibration …
-
Non-intrusive industrial load monitoring on a factory in Brazil
… of Non-Intrusive Load Monitoring applied to electrical data collected from a factory in Brazil. NILM proposes to separate single-appliance power consumption from consumers total demand without the need for installation of intrusive sensors or more than one meter per building. As the main …
-
Characterizing and Real-Time Monitoring of Various Types of Waters and Wastewaters Contaminated With Algae, Recycled Plastic Powders, and Clay Using the New Electrical Methods With Vipulanandan Models
… and relaxation time (τ = Rc × Cc). Distinct electrical signatures were observed for each contaminant: algal samples exhibited dielectric variation; nitric acid and NaOH showed dominant ionic conduction; PLA and bentonite displayed interfacial polarization effects. Strong correlations were …
-
Design and Fabrication of Nanofluidic Systems with Integrated Sensing Electrodes for Rapid Biomolecule Characterization
… I-V curve measurements of fluids with different electrical conductivities in the nanochannel. As a proof of concept for biomolecule characterization, negatively-charged nanobeads (20-nm yellow-green FluoSpheres®) were translocated through the nanochannel and their corresponding electrical …
-
Characterization [of] nucleic acids unwinding and exploring its application in miRNA detection in the nanopore
… a signature current pattern that can be used to electrically track the double-stranded DNA (dsDNA) unzipping process. With the signature signals, we can also distinguish the release of dsDNA without unzipping. Second, based on the electrical signatures we identified, we have designed a …
-
Inspection of Earthen Embankment Dams Using Time Lapse Electrical Resistivity Tomography
… more confident evaluation of a dam's integrity. Electrical resistivity is one geophysical technique that would be useful in detecting internal flaws associated with seepage and piping because it is sensitive to moisture changes. A study is being conducted to examine the feasibility of electrical …
-
Application of chemically modified oligonucleotides in nanopore sensing and DNA nano – biotechnology
… pore. The resulting characteristic current signatures are specific for the chemical composition and the size of the tags. The unique electrical signatures can be exploited to encode sequence information as demonstrated for the discrimination between drug resistance-conferring point …
-
Identification of distributed energy resources in low voltage distribution networks
… and security of supply on this side of the electrical systems. In this regard, this thesis explores techniques to actively monitor these systems in low voltage distribution systems. <br/><br/>Non-intrusive load monitoring (NILM) method, commonly used for energy management systems, contribute …
-
Electrochemical Characterization of Different Types of Waters and Their Effects on Cement Paste Hydration Properties Using the Electrochemical Impedance Spectroscopy, Vipulanandan Models, and Artificial Neural Network
… waters and predicts cement-paste strength from electrical signatures alone. Seven waters were studied: City Tap (CTW), Rain (CRW), Bottled (CBW), Sea (CSW), Pond (CPW), Algal Culture Medium (CALG) and Spent Coffee-Powder Suspension (CSCP). Each was characterized by the Vipulanandan Case-2 …
-
Sensorless fault diagnosis of centrifugal pumps
Analysis of electrical signatures has been in use for some time to assess the condition of induction motors. In most applications, induction motors are used to drive dynamic loads, such as pumps, fans, and blowers, by means of belts, couplers and gear-boxes. Failure of either the electric motors or …
-
Electronic properties of defects in silicon and related materials.
… efficient structures. This thesis presents the electrical characterisation of two different diode structures that are important for the present and future generations of electronic devices.The first part of the thesis is focused on the electrical characterisation of Ultra-Shallow Junction (USJs) …
-
Mircofluidic Systems for High-throughput Biophysical Characterization of Single Cells
Biophysical (mechanical and electrical) properties of living cells have been proven to play important roles in the regulation of various biological activities at the molecular and cellular level, and can serve as promising label-free markers of cells' physiological states. In the past two decades, …
-
Developing bioelectronic sensors for 3D in vitro models at the air liquid interface: Innovative technology for biomedical and respiratory research.
… 32 days, and, permits continuous, simultaneous electrical readouts. The third goal was technology-focused and resulted in the design and fabrication of a novel microelectronic device that was capable of monitoring epithelial barrier function and perturbations of primary *in vitro* models at the …
-
Investigation of Electrical Properties on Material by Modifying Interfacial and Grain Surface Properties
… it is not clear what mechanisms affecting the electrical properties of a porous medium, especially those leading to alteration of the pore space and mineral surfaces are responsible for the observed polarization in electrical signatures. A general objective of this work, therefore, is to test …
-
Développement de capteurs logiciels pour la détection de défauts mécaniques dans les entraînements électriques à vitesse variable : Application à la maintenance prédictive des éoliennes
Cette thèse est consacrée à la détection de défauts mécaniques dans les machines synchrones à partir des mesures électriques à vitesse variable. L'application visée est l'éolien. L'approche proposée est basée sur les méthodes d'order tracking dans lesquelles les signaux d'analyse sont …
-
Conception d’un jumeau numérique pour un procédé d’aspiration industrielle
Cette thèse est consacrée à la conception d’un jumeau numérique pour système de ventilation industriel dans un contexte de surveillance et de diagnostic. Les mesures d’entrées du modèle sont exclusivement électriques et aucun capteur mécanique n’est utilisé. Les cas particuliers de la vitesse fixe …
-
Προσδιορισμός και μελέτη των μετα-μεταγραφικών τροποποιήσεων Ν6-μεθυλαδενοσίνη και 5-μεθυλοκυτοσίνη των ανθρώπινων mRNAs στον καρκίνο του μαστού
… the nanopore, thereby capturing the intrinsic ‘electrical signatures’ of modifications without the need for chemical treatment, reverse transcription, or amplification. Such an approach enables the simultaneous acquisition of both primary sequence and epitranscriptomic information at …
Page 1 of 2