Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"Electrocautery"”.

  1. Iatrogenic Electrocautery Damage and Cellular-Based Corrosion of Total Joint Arthroplasty Biomaterials

    … for debate, with some believing it is caused by Electrocautery (EC) damage at the time of surgery and others believing it is caused by inflammatory cells attacking the implant surface. The purpose of this thesis is to identify to what degree Electrocautery damage can alter the implant surface and …

    tenn-hsc Repository record for Iatrogenic Electrocautery Damage and Cellular-Based Corrosion of Total Joint Arthroplasty Biomaterials (opens in a new tab)

  2. Caracterización de pacientes adultos con epistaxis por varices septales tratados con electrocauterización en hospital universitario Méderi mayor

    … in our country where epistaxis is managed with electrocautery in the office. Objective: To describe the characteristics of adult patients with epistaxis due to septal varices treated with electrocautery at Hospital Universitario Mayor Mederi, Bogotá, from August 2021 to May 2022. Methods: A …

    rosario Repository record for Caracterización de pacientes adultos con epistaxis por varices septales tratados con electrocauterización en hospital universitario Méderi mayor (opens in a new tab)

  3. CHARACTERIZATION OF SURGICAL PLUME AEROSOLS AND ASSESSMENT OF OCCUPATIONAL EXPOSURES AMONG OPERATING ROOM PERSONNEL

    … The four surgical instruments used were an electrocautery knife, a carbon dioxide laser, a harmonic scalpel, and a neutral plasma coagulator system (i.e., Plasma JetTM). At the point of generation, geometric mean (GM) particle number concentrations ranged from 7.11E+05 particles per cubic …

    jhu Repository record for CHARACTERIZATION OF SURGICAL PLUME AEROSOLS AND ASSESSMENT OF OCCUPATIONAL EXPOSURES AMONG OPERATING ROOM PERSONNEL (opens in a new tab)

  4. Algorithms & software for intelligent patient monitoring

    … An algorithm has been developed for detecting electrocautery noise in the electrocardiogram (ECG) using wavelet analysis. Electrocautery noise can lead an expert system to make incorrect diagnoses. In 15 surgical cases spanning 38.5 hours of ECG data, we achieved a false positive rate of 0.71% …

    ubc Repository record for Algorithms & software for intelligent patient monitoring (opens in a new tab) Download PDF for Algorithms & software for intelligent patient monitoring (opens in a new tab)

  5. Cellular Corrosion of CoCrMo Total Knee Implants: Understanding Underlying Mechanisms Through Retrieval Analysis and Simulated Inflammatory Conditions

    … of the oxide layer. However, damage caused by electrocautery tools has shown identical characteristics, leading some to believe this is the true cause. This study aims to distinguish between these two damage mechanisms and investigate the biological response of inflammatory cells to common …

    tenn-hsc Repository record for Cellular Corrosion of CoCrMo Total Knee Implants: Understanding Underlying Mechanisms Through Retrieval Analysis and Simulated Inflammatory Conditions (opens in a new tab)

  6. The Effect of Treatment of the Healing Time of Experimentally Induced Granulomatous Ulcers Due to Barium Sulfate in the Rectum of a Dog

    … edges of the uncers were debrided and the electrocautery was applied to the necrotic ulcer base. The subsequent rapid healing of the ulcers was attributed to the asucerization and promoting of drainage. The purpose of this experiment is to induce barium granulomatous ulcers in dogs and to …

    marquette Repository record for The Effect of Treatment of the Healing Time of Experimentally Induced Granulomatous Ulcers Due to Barium Sulfate in the Rectum of a Dog (opens in a new tab)

  7. On Patellofemoral joint replacement - Clinical, radiological, and numerical studies.

    … primary total knee replacement. Circumpatellar electrocautery in total knee replacement is used by approximately 50% of orthopaedic surgeons in The Netherlands. The use of electrocautery results in a lower prevalence of anterior knee pain and better functional results.

    radboud Repository record for On Patellofemoral joint replacement - Clinical, radiological, and numerical studies. (opens in a new tab) Download PDF for On Patellofemoral joint replacement - Clinical, radiological, and numerical studies. (opens in a new tab)

  8. Η συμβολή του νυστερίου υπερήχων και της ηλεκτροθερμικής μεθόδου έμφραξης των αγγείων στην αποτροπή του υγρώματος στην τροποποιημένη ριζική μαστεκτομή

    … three groups: twenty (20) were treated via the electrocautery method, twenty (20) via the harmonic scalpel and twenty (20) via the electrothermal bipolar vessel sealing system. Electrocautery is a method of producing heat in the tissues with the use of high frequency electric current. The …

    greece Repository record for Η συμβολή του νυστερίου υπερήχων και της ηλεκτροθερμικής μεθόδου έμφραξης των αγγείων στην αποτροπή του υγρώματος στην τροποποιημένη ριζική μαστεκτομή (opens in a new tab)

  9. Degradation of Cobalt Chrome Molybdenum Hip And Knee Implants in Vivo and in Vitro

    … what effect the secondary damage modes such as electrocautery damage and adhesive wear have on these devices. In this thesis we (1) create a semi-quantitative wear score for explanted CoCrMo femoral condyles; (2) determine if the wear score correlates with ion release into the periprosthetic …

    clemson Repository record for Degradation of Cobalt Chrome Molybdenum Hip And Knee Implants in Vivo and in Vitro (opens in a new tab)

  10. Topical treatments of anal high-grade squamous intraepithelial lesions for anal cancer prevention

    … lesions (HSIL). While ablative therapies like electrocautery and surgical excision are commonly used, they can be invasive, expensive, and associated with considerable morbidity. For those reasons, there is interest in the use of topical therapies in the treatment of anal HSIL. While no …

    bu Repository record for Topical treatments of anal high-grade squamous intraepithelial lesions for anal cancer prevention (opens in a new tab)

  11. Advances in Autonomous Vision-Guided Robotic Soft Tissue Surgery

    … system solutions automate suturing and electrocautery in soft tissue surgeries, achieving surgical outcomes comparable to those of skilled surgeons. The developed robotic systems were evaluated through tissue phantom experiments, ex vivo cadaver studies, and preclinical in vivo animal …

    jhu Repository record for Advances in Autonomous Vision-Guided Robotic Soft Tissue Surgery (opens in a new tab) Embargoed until 2028-05-01

  12. Anti-Inflammatory Effects of PPAR-gamma in Surgical Brain Injury (SBI)

    … retractor stretch, intraoperative hemorrhage and electrocautery damage. As a result of this surgical brain injury (SBI) postoperative complications such as inflammation, brain edema, and cell death can occur in the susceptible brain areas. Cerebral inflammation is a known contributor to the …

    loma-linda Repository record for Anti-Inflammatory Effects of PPAR-gamma in Surgical Brain Injury (SBI) (opens in a new tab)

  13. Perioperative Considerations of a Patient with Implementable Pacemaker

    … to the myocardial tissue (Zaidan et al., 2005). Electrocautery can be a significant source of EMI in the operative setting, if proper precautions are not taken to decrease the incidence (Dawes et al., 2006).

    nodak Repository record for Perioperative Considerations of a Patient with Implementable Pacemaker (opens in a new tab)

  14. Development of a liquid drug delivery payload for modular, wireless, incorporeal robots for laparoscopic surgery

    … need for a relatively large energy source for electrocautery tools and harmonic scalpels. An incorporeal robot capable of carrying and delivering liquids would combine the advantages of incorporeal mobile robots and liquid hemostatic agents. The main focus of this thesis is the development of a …

    uiuc Repository record for Development of a liquid drug delivery payload for modular, wireless, incorporeal robots for laparoscopic surgery (opens in a new tab)

  15. Creation of an Autonomous, Fluorescence-Based Tissue Diagnostic and Ablation Device for use in Brain Tumor Resection

    … CT scans) and manual resection tools (such as electrocautery and forceps). Unfortunately, this current paradigm offers hurdles that stand in the way of more precise, accurate tumor resection. These hurdles include the physical phenomenon of brain shift and the natural limitation of the human …

    duke Repository record for Creation of an Autonomous, Fluorescence-Based Tissue Diagnostic and Ablation Device for use in Brain Tumor Resection (opens in a new tab)

  16. Design, development, and evaluation of meso-scale robotic system for deep intracranial tumor removal

    … robot that is tendon-driven and equipped with electrocautery, suction and irrigation capabilities. A novel central tendon routing mechanism has been employed to enable independent segment control in a tight workspace. To improve stability of the surgical procedure, a stiffness tunable MINIR-II …

    gatech Repository record for Design, development, and evaluation of meso-scale robotic system for deep intracranial tumor removal (opens in a new tab)

  17. Contemporary surgical treatment of benign prostate hyperplasia, advantages of different surgical methods. literature review /

    … studies of holmium laser and conventional electrocautery have shown comparable improvement in symptoms. However, holmium laser incision of the bladder neck provides better hemostasis but carries risks such as retrograde ejaculation. For patients with slightly larger prostates or when …

    vilnius Repository record for Contemporary surgical treatment of benign prostate hyperplasia, advantages of different surgical methods. literature review / (opens in a new tab)

  18. Inflammation and Corrosion in Total Hip Prostheses: The Generation and Interaction of Reactive Oxygen Species with CoCrMo Metallic Biomaterial Surfaces

    … CoCrMo retrievals and CoCrMo surfaces damaged by electrocautery and ROS-rich solutions were shown to have significantly (p < 0.05) decreased corrosion resistance (RP) with increased constant phase element capacitance (CPE Q) and open circuit potentials (OCPs), indicating that ROS are major …

    clemson Repository record for Inflammation and Corrosion in Total Hip Prostheses: The Generation and Interaction of Reactive Oxygen Species with CoCrMo Metallic Biomaterial Surfaces (opens in a new tab)

  19. Design, Modeling and Control of Micro-scale and Meso-scale Tendon-Driven Surgical Robots

    … meso-scale two degree-of-freedom robotic bipolar electrocautery tool that increases the workspace of the neurosurgeon. A static model is proposed for the robot joints that avoids problems arising from pure kinematic control. Using this model, a control system is developed that comprises of a …

    gatech Repository record for Design, Modeling and Control of Micro-scale and Meso-scale Tendon-Driven Surgical Robots (opens in a new tab)

  20. Counterpulsation cardiac assist device controller defection filter simulation and canine experiments

    … interference due to mechanical ventilation, electrocautery, signal attenuation and random noise was present. The robust Pa triggering algorithm was based on a derivative comparator "riding clipper" algorithm for the Pa-based controller. In order to empirically determine the robustness of the …

    njit Repository record for Counterpulsation cardiac assist device controller defection filter simulation and canine experiments (opens in a new tab)

Page 1 of 2