Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 68 for “"Electroencephalograph"”.
-
Personality correlates of the electroencephalograph
Master of Science (M.S.)
-
Clinical applications of the quantitative electroencephalograph
… previously studied in detail. The quantitative electroencephalograph (QEEG) is a dynamic neuroimaging tool that allows for the measurement of brain activity. QEEG source localization analysis has provided additional construct validity for neuropsychological tests by revealing increased …
-
RECOGNITION OF PRIMARY COLOURS IN ELECTROENCEPHALOGRAPH SIGNALS USING SUPPORT VECTOR MACHINES
In this study we have worked on the classification of EEG signals produced by the exposure of primary colours (RGB). The main goal of this study was to perform an offline analysis and classification of color information obtained from EEG signals recorded in response to individual RGB colours …
-
Electroencephalograph predictors of central neuropathic pain in subacute spinal cord injury
Abstract not currently available.
-
Optimization of Electroencephalograph-Based Classification for Imaginary Motion Brain Computer Interface Study
Using Electroencephalography (EEG) to detect imaginary motions from brain waves, to interface human and computer is a very nascent and challenging field that started developing rapidly in the past few decades. The technique involves some electrodes attached on the scalp of the patient and the …
-
Electroencephalograph (EEG) signal processing techniques for motor imagery Brain Computer interface systems
Brain-Computer Interface (BCI) system provides a channel for the brain to control external devices using electrical activities of the brain without using the peripheral nervous system. These BCI systems are being used in various medical applications, for example controlling a wheelchair and …
-
Žmogaus akių mirksnių atpažinimas su neuroniniais tinklais iš žmogaus smegenų elektroencefalografijų /
… suitable for recognition of eye blinks in human electroencephalography data, collected using electroencephalograph provided by UAB “Neurotechnology”. Three distinct neural network architectures, identified through a comprehensive literature review, were compared in two separate experiments. Data …
-
Use case analysis: the ambulatory EEG in navy medicine for traumatic brain injuries
Implementing the ambulatory electroencephalograph (EEG) system can expedite potentially emergent results, reduce patients' time spent in the hospital, eliminate the need for specialized technicians to administer the electrodes, reduce the bulky EEG equipment that takes up space and limited …
-
Improving the performance of GIS/spatial analysts though novel applications of the Emotiv EPOC EEG headset
… increase productivity with a wireless, wearable, electroencephalograph (EEG) headset within the geospatial workflow.
-
Neuropsychological and Electrophysiological Assessment of Adults with Attention Deficit Hyperactivity Disorder
… Performance Test (IVA). The quantitative electroencephalograph (QEEG) was also collected during task performance to examine possible difference in cortical activity between groups and tasks. Results suggest that adults with ADHD demonstrate lower levels of performance on neuropsychological …
-
Physiological correlates of therapeutic rapport: an analysis of brainwave patterns
… there were recognizable similarities in the electroencephalograph (EEC) patterns of a client and a counselor during times of self-reported rapport in a therapy session. Study participants (one counselor and three female senior psychology student volunteers) were connected to an EEC machine …
-
Quantitative differences in participants exposed to patterned, weak-intensity electromagnetic fields: investigating the shiva
… brain activity were measured using quantitative electroencephalograph and subjective reports of experiences were examined. The investigation included two different configurations of the Shiva technology. Results indicated that individuals exposed to specific patterned fields exhibited different …
-
Human control of robots over discrete noisy channels with high latency: toward efficient EEG-based brain-robot interfaces
… at high latency from a human user (e.g., with an electroencephalograph) to control a robotic system (e.g., a robotic wheelchair) that can provide visual feedback. In this framework, the human user communicates their intent by providing inputs in response to queries posed by the robot. The …
-
Identification and Use of PSD-Derived Features for the Contextual Detection and Classification of EEG Epileptiform Transients
… trained neu-rologists go over the patient’s EEG (Electroencephalograph) records looking for epileptic transients. This is a tedious and long process. The objective of this thesis is to automate the procedure by developing a detector that would pick out epileptic transients containing the ”Abnormal …
-
An electroencephalographic comparison of Lowenfeld's haptic-visual and Witkin's field-dependent-field-independent perceptual types
… tactile, and kinesthetic stimuli while an electroencephalograph (EEG) recorded their alpha wave responses eminating from the occipital lobe of the brain. Since alpha waves have consistently been found to be negatively associated with visual imagery, it was hypothesized that Lowenfeld's …
-
Comparison of physiological correlates accompanying transcendental meditation and relaxation period
… muscle activity, cephalic vasomotor activity and electroencephalograph measurements were obtained from twenty-four subjects in order to test the hypothesis that the practice of Transcendental Meditation is associated with a hypometabolic state. Sixteen of the subjects were experienced …
-
The effects of galvanic vestibular stimulation on motor cortical related potentials in Parkinson's disease
… (GVS) on reaction time and MRCPs in PD using electroencephalograph (EEG) to better understand its underlying physiological mechanisms. All Seventeen participants with a diagnosis of Parkinson’s disease completed a voluntary finger and foot tapping task and seven participants also completed a …