Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 24 for “"Electrogoniometry"”

  1. Wrist and thumb joint postures and motions - measurements using electrogoniometry and EMG

    … reduce effort and/or facilitate productivity. Electrogoniometry offers a relatively simple and objective way to measure joint postures and motions. The expectation is that electrogoniometric instruments will provide better measures of postures and movements than the more subjective methods such …

    goteborg Repository record for Wrist and thumb joint postures and motions - measurements using electrogoniometry and EMG (opens in a new tab)

  2. Comparison of forward hockey skating kinetics on ice and on a synthetic surface by means of a customized force measurement system and electrogoniometry

    Étant donné les défis techniques de mesure de la force au cours du patinage sur glace, peu de choses sont connues quant à la dynamique de cette unique forme de locomotion. Par conséquent, le premier objectif de cette étude a été de développer un système portable de mesure de la force, et le second …

    mcgill Repository record for Comparison of forward hockey skating kinetics on ice and on a synthetic surface by means of a customized force measurement system and electrogoniometry (opens in a new tab)

  3. Avaliação das amplitudes de movimento do cotovelo, antebraço e punho durante manuseio de carga em um setor industrial

    … record the wrist, forearm and elbow movements. Electrogoniometry was used to record the movements of seven experienced workers during a real activity in an occupational environment. Most of the workers positioned their hands on the load asymmetrically, and the box handles were not used. Large …

    brazil-ufscar Repository record for Avaliação das amplitudes de movimento do cotovelo, antebraço e punho durante manuseio de carga em um setor industrial (opens in a new tab)

  4. Physical exposure, musculoskeletal symptoms and attitudes related to ICT use

    … and wrist positions/movements with electrogoniometry during work with a traditional flat computer mouse (pronated hand position) and a vertical computer mouse (neutral hand position). Work with the vertical computer mouse decreased the muscle activity in the extensor muscles in the …

    goteborg Repository record for Physical exposure, musculoskeletal symptoms and attitudes related to ICT use (opens in a new tab)

  5. Quantification of abnormal muscle tone following spinal cord injury: A clinical perspective

    … techniques: therapist rating, patient rating, electrogoniometry and dynamometry augmented by polyelectromyography, prior to implementing the combined assessment programme in a group of spinal cord injured and neurologically intact subjects. The relationships between the findings of each …

    ucl Repository record for Quantification of abnormal muscle tone following spinal cord injury: A clinical perspective (opens in a new tab)

  6. Análise do controle motor após treino em esteira com suporte parcial de peso corporal em pacientes com hemiplegia crônica

    … plantar flexion muscular groups of the ankle and electrogoniometry of the dorsiflexion and plantar flexion of the ankle. Eight subjects concluded the experiment. Three patients had better outcomes after 5 times a week treatment, two patients showed improvement only when the treatment was performed …

    brazil-ufscar Repository record for Análise do controle motor após treino em esteira com suporte parcial de peso corporal em pacientes com hemiplegia crônica (opens in a new tab)

  7. Biomechanical analysis of fixed bearing and mobile bearing total knee prostheses

    … motion analysis in the laboratory and electrogoniometry and accelerometry during free living conditions. No differences were found between FB and MB groups during walking at post-surgery that could not be explained by differences at pre-surgery. There were also no differences between FB …

    northumbria Repository record for Biomechanical analysis of fixed bearing and mobile bearing total knee prostheses (opens in a new tab)

  8. Masticatory muscles activities in temporomandibular joint internal derangement.

    … EMG of the temporalis and masseter muscles, electrogoniometry and force measurements of the TMJ were synchronously used to investigate the biomechanical role of the two portions of the lateral pterygoid muscle in relation to internal derangement (ID) of the temporomandibular joint (TMJ). This …

    ottawa-retro Repository record for Masticatory muscles activities in temporomandibular joint internal derangement. (opens in a new tab)

  9. Functional assessment to compare electromagnetic navigated and conventional total knee arthroplasty

    … included a kinematic evaluation using flexible electrogoniometry, calculation of the hamstring and quadriceps moment while the knee joint was flexed to 90º, an activity level assessment using an activity monitor and clinical and functional questionnaires. The alignment of the prosthesis within …

    strathclyde Repository record for Functional assessment to compare electromagnetic navigated and conventional total knee arthroplasty (opens in a new tab)

  10. Medidas diretas na avaliação da exposição biomecânica de trabalhadores em ambiente real

    … Study 1 discusses the use of inclinometry, electrogoniometry and electromyography to quantify the biomechanical exposure of industrial workers from the automotive sector, comparing two production lines (one manual and one semiautomated). For this purpose, postures and movements of the head, …

    brazil-ufscar Repository record for Medidas diretas na avaliação da exposição biomecânica de trabalhadores em ambiente real (opens in a new tab)

  11. Detecting kinematic gait abnormalities in people with multiple sclerosis using clinically practical measures

    … clinical questions about MS. Wireless flexible electrogoniometry (EG) is a clinically practical measure of joint angles. The GAITRite walkway system is a clinically practical, valid and reliable measure of temporal and spatial gait characteristics. The overall objective of this two-study …

    sask Repository record for Detecting kinematic gait abnormalities in people with multiple sclerosis using clinically practical measures (opens in a new tab)

  12. Flexor tendon motion and shear in the carpal tunnel: implications for work

    … flexed (Chapter 4). Using colour flow imaging, electrogoniometry, and fine-wire EMG, relative displacement was found to increase with tendon velocity and force (Chapter 5). Relative displacements in Chapters 3 to 5 were combined into a prediction model, and further compared to a tendon friction …

    mcmaster Repository record for Flexor tendon motion and shear in the carpal tunnel: implications for work (opens in a new tab)

  13. Exposição biomecânica durante o manuseio de caixas em ambiente real e simulado com trabalhadores industriais

    … was randomized. In addition to direct measures (electrogoniometry, inclinometry and electromyography) subjective scales were used to assess the comfort and perceived effort. In general, both experienced and inexperienced subjects had lower biomechanics load handling non-commercial boxes compared …

    brazil-ufscar Repository record for Exposição biomecânica durante o manuseio de caixas em ambiente real e simulado com trabalhadores industriais (opens in a new tab)

  14. An Exploration of the Influence of Activity and Occupation on Recovery from a Surgically Treated Distal Radius Fracture

    … during purposeful activities was evaluated using electrogoniometry and compared with movement during active range of motion exercises. The study provided novel data demonstrating that significantly greater volumes of movement are produced by performing purposeful activities than previously …

    auckland-tech Repository record for An Exploration of the Influence of Activity and Occupation on Recovery from a Surgically Treated Distal Radius Fracture (opens in a new tab)

  15. The effects of segmental vibration on hamstring range of motion

    … points (baseline, Post 1, Post 2) measured with electrogoniometry. The AKE and PSLR tests were performed three times on each leg, at each time-point. The mean baseline AKE measurements were used to determine which leg was least flexible and would receive the vibration intervention (experimental), …

    unitec Repository record for The effects of segmental vibration on hamstring range of motion (opens in a new tab)

  16. Avaliação de pegas e sobrecarga dos membros superiores durante o manuseio de caixas : aspectos biomecânicos e perceptuais

    … and elbows were objectively evaluated through electrogoniometry. The boxes had already received an ergonomic intervention, implemented six months before the data collection. The ergonomic intervention evaluated was the insertion of cutout handles in the cardboard boxes. The main results …

    brazil-ufscar Repository record for Avaliação de pegas e sobrecarga dos membros superiores durante o manuseio de caixas : aspectos biomecânicos e perceptuais (opens in a new tab)

  17. Análise cinesiológica e biomecânica de atividades de manuseio de carga

    … wrist radial and ulnar deviations quantified by electrogoniometry. Ten male volunteers participated in this study handled a box between surfaces of different heights. The activities was performed to evaluate significant differences between the anthropometry of volunteers´ hands and between …

    brazil-ufscar Repository record for Análise cinesiológica e biomecânica de atividades de manuseio de carga (opens in a new tab)

  18. Neuro-Mechanical Analysis of Eccentric Overload of Elbow Flexors

    Eccentric overload in training settings utilizes loads higher than concentric one repetition maximum (1RM). There is no clear definition of eccentric “failure” or 1RM using conventional weights, so eccentric 1RM is estimated to be between 145-190% concentric 1RM. Historically, the highest intensity …

    sask Repository record for Neuro-Mechanical Analysis of Eccentric Overload of Elbow Flexors (opens in a new tab)

Page 1 of 2