Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Electrokinetic flow"”.

  1. Nonlinear Electrokinetic Flow near Permselective Membrane

    We conducted numerical studies on the nonlinear electrokinetic flow developing near permselective membrane. Numerical methods were developed to solve for the Poisson-Nernst-Planck-Navier-Stokes equations. It was demonstrated that, under a significantly high electric field, an electroconvective …

    nus Repository record for Nonlinear Electrokinetic Flow near Permselective Membrane (opens in a new tab) Download file for Nonlinear Electrokinetic Flow near Permselective Membrane (opens in a new tab)

  2. Numerical methods and simulation for time dependent electrokinetic flow

    <p>Electrokinetic flow typically occurs when an electric field is applied to a fluid electrolyte in the presence of a boundary or interface. The electric field induces a force that causes oppositely charged ions to migrate in opposite directions while simultaneously diffusing due to Brownian …

    njit Repository record for Numerical methods and simulation for time dependent electrokinetic flow (opens in a new tab)

  3. Modelling of electrokinetic flow using the lattice-Boltzmann method

    … lattice-Boltzmann method is used to model ow in electrokinetic systems. A modelling approach based on the coupling of Navier-Stokes, Nernst-Planck and Poisson's equation of electrostatics is utilised. Three lattice-Boltzmann methods are formulated for the three equations respectively. The method …

    chalmers Repository record for Modelling of electrokinetic flow using the lattice-Boltzmann method (opens in a new tab)

  4. Electrokinetic Flow Instabilities in Non-Newtonian Fluids With Conductivity Gradients

    Electrokinetic instabilities (EKI) arise in electrically driven flows because the applied electric field interacts with spatial variations in electrical conductivity, generating electric body forces that can destabilize fluid interfaces. EKI can be beneficial by enhancing mixing in microchannels …

    clemson Repository record for Electrokinetic Flow Instabilities in Non-Newtonian Fluids With Conductivity Gradients (opens in a new tab)

  5. Electrokinetic Flow in a Nanochannel with an Overlapped Electrical Double Layer

    … to improve the understanding of nanofluidic flows. Nanofluidic flows have a wide range of potential application in many fields, such as DNA analysis, drug delivery, analyte separation, power generation, and so on. The most common material used in nanofluidic flows is silica whose surfaces are …

    utahstate Repository record for Electrokinetic Flow in a Nanochannel with an Overlapped Electrical Double Layer (opens in a new tab)

  6. Microfluidic Interfaces for Coupling Hydrodynamic to Electrokinetic Flow and Microchannel Electrophoresis to Electrospray Ionization-Mass Spectrometry

    … interface for coupling hydrodynamic and electrokinetic flows, this interface was first studied theoretically and then experimentally to evaluate the electrophoretic extraction of a negatively charged analyte from a perpendicular hydrodynamic flow stream. Secondly the interface was used to …

    wvu Repository record for Microfluidic Interfaces for Coupling Hydrodynamic to Electrokinetic Flow and Microchannel Electrophoresis to Electrospray Ionization-Mass Spectrometry (opens in a new tab)

  7. Single Molecule Studies In A Nanofludic Channel: Detection And Sorting For Epigenetic Analysis

    … many molecules is achieved by voltage-actuated, electrokinetic flow within the nanofluidic device to precisely control molecule analysis rate and achieve high throughput single molecule detection (SMD). This nanofluidic technology is applied to epigenetic analysis, enabling the study of …

    cornell Repository record for Single Molecule Studies In A Nanofludic Channel: Detection And Sorting For Epigenetic Analysis (opens in a new tab)

  8. Monte Carlo Simulations of Single-Molecule Fluorescence Detection Experiments

    … move along the nanochannel by diffusion and electrokinetic flow. Single-molecule fluorescence signals excited by two spatially offset laser beams are detected and the direction of the flow is adjusted to try to equalize the signals and center the molecule between the beams. An algorithm is …

    utk-theses Repository record for Monte Carlo Simulations of Single-Molecule Fluorescence Detection Experiments (opens in a new tab)

  9. Electrokinetic Phenomena and Singularity-Driven Flows in Nematic Liquid Crystals

    Electrokinetic phenomena, including electrophoresis and electroosmosis, provide a significant tool for engineering the transport of fluids and particles at microscopic scales. This thesis describes additional mechanisms for generating electrokinetic flow by using a nematic liquid crystal …

    umn Repository record for Electrokinetic Phenomena and Singularity-Driven Flows in Nematic Liquid Crystals (opens in a new tab)

  10. DEVELOPMENT OF A XENOGRAFT FOR ANNULAR REPAIR USING PULSED ELECTRIC FIELD EXPOSURES FOR ENHANCED DECELLULARIZATION

    … the removal of immunogenic biomolecules though electrokinetic extraction using optimized aqueous solutions. This approach yields a natural scaffold, ready for biocompatibility and mechanical strength assessment. The effects of microsecond pulsed electric fields (µsPEF) on primary bovine AF …

    rowan Repository record for DEVELOPMENT OF A XENOGRAFT FOR ANNULAR REPAIR USING PULSED ELECTRIC FIELD EXPOSURES FOR ENHANCED DECELLULARIZATION (opens in a new tab)

  11. Experiment and simulation of single-molecule recycling

    … a laser beam into the nanochannel and applying electrokinetic flow along the tube, a molecule passes through the laser beam and emits a burst of photons. The molecule then passes back and forth through the focus while the voltage is repeatedly reversed at a fixed delay after each detected burst. …

    utk-theses Repository record for Experiment and simulation of single-molecule recycling (opens in a new tab)

  12. The use of photopolymers as retaining frits and monoliths for electrochromatography in capillaries or microfluidic devices and some selected applications

    … without sacrificing resolution. Hydrodynamic and electrokinetic flow measurements gave insights into the porosity and tortuosity of the polymer by non-destructive means. Additionally, scanning electron microscopy and atomic force microscopy were employed to elucidate the microscopic structure and …

    concordia Download PDF for The use of photopolymers as retaining frits and monoliths for electrochromatography in capillaries or microfluidic devices and some selected applications (opens in a new tab)

  13. Single Molecule Particle Analysis using Nanotechnology

    … to test operation using both hydrodynamic and electrokinetic flows, which were verified via experimentation to establish the functionality of the device to perform the above mentioned processes. The hydrodynamic flow operations used for spLDR was tested using Rhodamine B and the electrokinetic …

    ku Repository record for Single Molecule Particle Analysis using Nanotechnology (opens in a new tab)

  14. Microfluidic devices interfaced to matrix-assisted laser desorption/ionization mass spectrometry for proteomics

    … provided efficient digestion of proteins at a flow rate of 1 µL/min with a residence time of approximately 24 s in the reaction channel. An electrokinetically driven microreactor was also developed using a micropost structured chip for digestion. The micropost chip had a higher digestion …

    lsu-thes Repository record for Microfluidic devices interfaced to matrix-assisted laser desorption/ionization mass spectrometry for proteomics (opens in a new tab)

  15. Particle Separation Using Electrokinetically-Driven Deterministic Lateral Displacement: A Computational Study

    Electrokinetically-driven deterministic lateral displacement (e-DLD) is a recently proposed technique for continuous, two-dimensional fractionation of particle suspensions in microfluidic platforms. It utilizes the negative dielectrophoretic force that is induced by the DC electric field gradients …

    clemson Repository record for Particle Separation Using Electrokinetically-Driven Deterministic Lateral Displacement: A Computational Study (opens in a new tab)

  16. ELECTROKINETIC PARTICLE MANIPULATIONS IN SPIRAL MICROCHANNELS

    … in 'lab-on-a-chip' devices. This sub-domain of electrokinetic flow is particularly popular due to its advantages in simplicity and versatility. This thesis makes use of dielectrophoretic particle manipulations in three distinct spiral microchannels. In the first of these experiments, we …

    clemson Repository record for ELECTROKINETIC PARTICLE MANIPULATIONS IN SPIRAL MICROCHANNELS (opens in a new tab)

  17. JOULE HEATING EFFECTS ON ELECTROKINETIC TRANSPORT IN CONSTRICTION MICROCHANNELS

    … of Joule heating effects on electroosmotic fluid flow in iDEP is studied under various electric fields. It was determined that depending upon the magnitude of DC voltage, a pair of counter rotating vortices fluid circulations can occur at either downstream end or each end of the channel …

    clemson Repository record for JOULE HEATING EFFECTS ON ELECTROKINETIC TRANSPORT IN CONSTRICTION MICROCHANNELS (opens in a new tab)

  18. Electrokinetic Manipulation of Particles and Cells in Microfluidic Devices

    … are many methods available for these techniques, electrokinetics has been rapidly gaining popularity due to the simplicity of application and removal of the need for in channel micro-structures. This thesis studies the use of electrokinetic flow and accompanying phenomena in various structured …

    clemson Repository record for Electrokinetic Manipulation of Particles and Cells in Microfluidic Devices (opens in a new tab)

  19. Development of an electrostatic peristaltic gas micropump and nanochannel fabrication technique

    … methods for controlling and manipulating fluid flows with length scales less than a millimeter. By miniaturizing the size, microfluidic systems lead to many benefits including decreased cost in manufacturing, use, and disposal; reduced consumption of expensive samples and reagent; decreased time …

    uiuc Repository record for Development of an electrostatic peristaltic gas micropump and nanochannel fabrication technique (opens in a new tab)

  20. MICROFLUIDIC PARTICLE AND CELL MANIPULATION USING RESERVOIR-BASED DIELECTROPHORESIS

    … motions in microfluidic devices, among which electrokinetic techniques are most often used. However, to date, studies of electrokinetic transport phenomena have been primarily confined within the area of microchannels. Very few works have addressed the electrokinetic particle motion at the …

    clemson Repository record for MICROFLUIDIC PARTICLE AND CELL MANIPULATION USING RESERVOIR-BASED DIELECTROPHORESIS (opens in a new tab)

Page 1 of 2