Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"Electromagnetic flowmeter"”

  1. The electromagnetic flowmeter

    Abstract Not Provided.

    glasgow Repository record for The electromagnetic flowmeter (opens in a new tab)

  2. Electromagnetic flowmeter for dielectric liquids.

    … investigation and theoretical analysis of an electromagnetic flowmeter designed for use with dielectric liquids has been carried out. An extensive survey of the industrial users of flowmeters has been made, involving the participation of over 47 companies, which provides information about the …

    cranfield Repository record for Electromagnetic flowmeter for dielectric liquids. (opens in a new tab)

  3. Development of baseline stability in an electromagnetic flowmeter for dielectric liquids

    … is concerned with the development of a prototype electromagnetic flowmeter for dielectric liquids. A initial prototype flowmeter is tested in laboratory conditions with a liquid of low conductivity, the conclusion of these initial tests being that the stability of the flowmeter is below that …

    cranfield Repository record for Development of baseline stability in an electromagnetic flowmeter for dielectric liquids (opens in a new tab)

  4. The improvement of meter performance of EM sensing flowmeters using software modelling

    … and power consumption of non-mechanical flowmeters such as the conventional electromagnetic flowmeter and the fluidic oscillator. Each flowmeter is studied using Finite Element Modelling for the magnetic field, the virtual current and the fluid dynamics in order to simulate flow signal. …

    cranfield Repository record for The improvement of meter performance of EM sensing flowmeters using software modelling (opens in a new tab)

  5. Electromagnetic flowmeters in multiphase flows

    The response of an Electromagnetic Flowmeter to a secondary, nonconducting phase in a continuous conducting phase is investigated. Experiments are carried out on a commercial 2" Foxboro flowmeter with sinusoidal mains field excitation and point electrodes. The main aspects which are looked for are …

    cranfield Repository record for Electromagnetic flowmeters in multiphase flows (opens in a new tab)

  6. Dispersion of Signal Averaged Pulsatile Blood Flow Waveforms Due to a Variable Heart Rate

    … thesis: photo-electric plethysmograph, doppler flowmeter, NMR blood flowmeter, electrocardiograph, and a pump system simulating blood flow on the extracorporeal electromagnetic flowmeter. Since these signals depend on the heart rate and the heart rate of a healthy individual varies even at rest, …

    marquette Repository record for Dispersion of Signal Averaged Pulsatile Blood Flow Waveforms Due to a Variable Heart Rate (opens in a new tab)

  7. Wave-induced water particle motion measurements

    … of water using a penetrating wave staff and an electromagnetic flowmeter. Moderate swell and low wind conditions prevailed during the experiment. The mea­sured wave-induced velocities were two to four percent greater than those predicted using linear wave theory. Coherence of the wave height and …

    nps Repository record for Wave-induced water particle motion measurements (opens in a new tab)

  8. Assessment of bovine uterine artery hemodynamics using Doppler ultrasound and a computer model

    … to uterine artery blood flow, pulsed Doppler, electromagnetic flowmeter, and continuous wave Doppler data were collected;A computer model of flow in the uterine artery was developed to study, theoretically, the effect of changes in various parameters on the blood velocity waveform;With regard …

    iastate Repository record for Assessment of bovine uterine artery hemodynamics using Doppler ultrasound and a computer model (opens in a new tab)

  9. Hydraulic Modeling of Floods in an Open Conduit Cave

    … relationship using two methods: A electromagnetic flowmeter and the salt dilution method. The stage-discharge relationship used to model stream flow was a result of measuring discharge at multiple stages. Five pressure transducers were deployed opportunistically along a …

    ohiolink Repository record for Hydraulic Modeling of Floods in an Open Conduit Cave (opens in a new tab)

  10. The computation of blood flow waveforms from digital X-ray angiographic data

    … flexible plastic tubing, the tubular probe of an electromagnetic flowmeter and a solenoid to simulate a pulsatile flow waveform which included reverse flow. The technique was validated for both two- and three-dimensional representations of the blood vessel, for various flow rates and calibre …

    ucl Repository record for The computation of blood flow waveforms from digital X-ray angiographic data (opens in a new tab)

  11. Evaluation of a Single Injection Radioiodinated Hippuran Technique for the Estimation of Renal Blood Flow in the Dog

    … of the latter include the ultrasonic and electromagnetic methods of measuring blood flow. The principle of the electromagnetic flowmeter introduced by Kolin is that when a conductor of electricity is moved through a magnetic field, a potential difference is created in the conductor, and …

    marquette Repository record for Evaluation of a Single Injection Radioiodinated Hippuran Technique for the Estimation of Renal Blood Flow in the Dog (opens in a new tab)

  12. Indukční průtokoměr

    Tato práce se zabývá problematikou indukčních průtokoměrů, se změřením na zásuvné indukční průtokoměry. Je zde podrobně rozebrán návrh takovéhoto průtokoměru: sonda, elektromagnet, elektrody, buzení a zpracování měřeného signálu. Dále pak měření takto navrženého průtokoměru, naměřené hodnoty, …

    brno-tech Repository record for Indukční průtokoměr (opens in a new tab)

  13. The Effects of Meter Orientation Downstream of a Short Radius Elbow on Electromagnetic Flow Meters

    Electromagnetic flowmeters (known as magnetic flow meters) are a widely used type of flowmeter. The accuracy of magnetic flow meters are a function of several factors, not the least of which is the flow condition inside the pipe. It has been shown that disturbances in the velocity profile affects …

    utahstate Repository record for The Effects of Meter Orientation Downstream of a Short Radius Elbow on Electromagnetic Flow Meters (opens in a new tab)

  14. Modélisation numérique de débitmètre électromagnétique

    Cette thèse a pour objet la modélisation et l’étude de débitmètres électromagnétiques produits par la société Siemens. Ces appareils permettent de mesurer le débit volumique d’un fluide conducteur en mouvement sous un champ magnétique par le biais d’électrodes mesurant le potentiel induit. …

    star-france Repository record for Modélisation numérique de débitmètre électromagnétique (opens in a new tab)

  15. An Analysis of Electromagnetic Flowmeters: A Numerical Study

    … water and wastewater systems is to use an electromagnetic (magnetic) flowmeter. A magnetic flowmeter has many components, and their accuracy can be compromised if not installed or calibrated correctly. The purpose of the present study was threefold. Each of the three components has been …

    utahstate Repository record for An Analysis of Electromagnetic Flowmeters: A Numerical Study (opens in a new tab)

  16. Podpůrný solární zdroj pro bateriový elektromagnetický průtokoměr

    Tato práce se zabývá návrhem podpůrného solárního zdroje pro bateriově napájený elektromagnetický průtokoměr. Cílem práce je rozšířit stávající architekturu zdroje, který obstarává veškeré napájení systému pomocí primárního článku, o solární nabíječ s akumulátorem, jenž bude schopen dosáhnout lepší …

    brno-tech Repository record for Podpůrný solární zdroj pro bateriový elektromagnetický průtokoměr (opens in a new tab)

  17. Indukční průtokoměr

    Bakalářská práce popisuje základní teoretický princip indukčního snímače. Jsou zde publikovány informace o vlastnostech průtokoměrů, jejich konstrukci, montáži a použití. Dále jsou popsány problémy, které se mohou objevit během realizace a činnosti těchto průtokoměrů. Částí práce je samotná …

    brno-tech Repository record for Indukční průtokoměr (opens in a new tab)