Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 31 for “"Electromechanical impedance"”

  1. Fatigue life estimation of 1-D aluminum beam using electromechanical impedance technique

    … smart materials, such as the electro-mechanical impedance (EMI) technique, employing the piezo-impedance transducers as collocated actuators and sensors, is known for its ability in damage detection and characterization. This study attempts to push forward this area of research, by developing a …

    nanyang Repository record for Fatigue life estimation of 1-D aluminum beam using electromechanical impedance technique (opens in a new tab)

  2. Towards Cyber-Physical Security for Additively Manufactured Parts via In Situ Monitoring and Electromechanical Impedance

    The layer-by-layer nature of additive manufacturing (AM) allows for toolless fabrication of highly complex geometries that cannot be made via traditional processes. AM is unique in its ability to precisely define both the material properties and geometric shape throughout the volume of a part, …

    vt Repository record for Towards Cyber-Physical Security for Additively Manufactured Parts via In Situ Monitoring and Electromechanical Impedance (opens in a new tab)

  3. Design of Crystal Filters

    This thesis concerns the application of electromechanical impedance elements to electric wave filters, so it is appropriate to begin with some discussion of such elements. The most important type is the piezoelectric resonator, most commonly made quartz.

    unm Repository record for Design of Crystal Filters (opens in a new tab)

  4. Structural Health Monitoring of Adhesively Bonded Joints With Piezoelectric Wafer Active Sensors

    … focus of this research was directed towards the electromechanical impedance method for disbond detection. The electromechanical impedance (EMI) method was modeled extensively with analytical and finite element method; the theoretical predictions were compared with carefully conducted experiments …

    south-carolina Repository record for Structural Health Monitoring of Adhesively Bonded Joints With Piezoelectric Wafer Active Sensors (opens in a new tab)

  5. High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification

    Over several decades, high-frequency electromechanical impedance measurements have been the basis of a nondestructive evaluation and health monitoring technique. These piezoceramic-based single-input-single-output measurements are quick to record and provide information about the host structure as …

    tamu Repository record for High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification (opens in a new tab) Embargoed until 2027-08-01

  6. High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification

    Over several decades, high-frequency electromechanical impedance measurements have been the basis of a nondestructive evaluation and health monitoring technique. These piezoceramic-based single-input-single-output measurements are quick to record and provide information about the host structure as …

    tamu Repository record for High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification (opens in a new tab) Embargoed until 2027-08-01

  7. High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification

    Over several decades, high-frequency electromechanical impedance measurements have been the basis of a nondestructive evaluation and health monitoring technique. These piezoceramic-based single-input-single-output measurements are quick to record and provide information about the host structure as …

    tamu Repository record for High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification (opens in a new tab) Embargoed until 2027-08-01

  8. High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification

    Over several decades, high-frequency electromechanical impedance measurements have been the basis of a nondestructive evaluation and health monitoring technique. These piezoceramic-based single-input-single-output measurements are quick to record and provide information about the host structure as …

    tamu Repository record for High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification (opens in a new tab) Embargoed until 2027-08-01

  9. High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification

    Over several decades, high-frequency electromechanical impedance measurements have been the basis of a nondestructive evaluation and health monitoring technique. These piezoceramic-based single-input-single-output measurements are quick to record and provide information about the host structure as …

    tamu Repository record for High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification (opens in a new tab) Embargoed until 2027-08-01

  10. High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification

    Over several decades, high-frequency electromechanical impedance measurements have been the basis of a nondestructive evaluation and health monitoring technique. These piezoceramic-based single-input-single-output measurements are quick to record and provide information about the host structure as …

    tamu Repository record for High Frequency Synthesis for Impedance Based Health Monitoring and Unique Part Identification (opens in a new tab) Embargoed until 2027-08-01

  11. Έλεγχος και επεμβάσεις δομικών στοιχείων από ωπλισμένο σκυρόδεμα με ειδικά τσιμεντοκονιάματα και ευφυή υλικά

    … methodologies for acquiring and evaluating the electromechanical responses of piezoelectric sensors. The Electromechanical Impedance method captures the variation of the electromechanical response of a piezoelectric patch attached to the structural element due to the degradation of its …

    greece Repository record for Έλεγχος και επεμβάσεις δομικών στοιχείων από ωπλισμένο σκυρόδεμα με ειδικά τσιμεντοκονιάματα και ευφυή υλικά (opens in a new tab)

  12. Development and Test of High-Temperature Piezoelectric Wafer Active Sensors for Structural Health Monitoring

    … sensor that utilizes langasite material. The Electromechanical impedance (E/M) method was chosen to detect the piezoelectric property. Experiments that verify the basic piezoelectric property of LGS at high temperature environments were carried out. Further validations were conducted by …

    unt Repository record for Development and Test of High-Temperature Piezoelectric Wafer Active Sensors for Structural Health Monitoring (opens in a new tab)

  13. Traveling Wave Thermoacoustic-Piezoelectric Energy Harvester: Theory and Experiment

    … in a two-part reduced-order model of the electromechanical impedance of the harvester. The predictions of the finite element model are compared with those of ANSYS finite element analysis and validated experimentally. The two-part model is utilized in a numerical analysis of the TWTAE …

    maryland Repository record for Traveling Wave Thermoacoustic-Piezoelectric Energy Harvester: Theory and Experiment (opens in a new tab)

  14. Characterization of smart PZT transducer and admittance signatures using PZT-structure interaction models for structural health monitoring

    … health monitoring (SHM) by the emergence of the electromechanical impedance (EMI) technique. This technique employs piezoelectric-ceramic (PZT) transducers for the prediction of structural response known as electromechanical (EM) admittance. Engineering structures can be classified into two …

    nanyang Repository record for Characterization of smart PZT transducer and admittance signatures using PZT-structure interaction models for structural health monitoring (opens in a new tab)

  15. Modeling and Experimental Analysis of Piezoelectric Augmented Systems for Structural Health and Stress Monitoring Applications

    … and loading monitoring, with focus being cast on impedance-based SHM and acoustoelastic-based stress measurement techniques. While impedance-based SHM has been successfully implemented as a damage detection technique, the utilization of electromechanical impedance measurements for damage …

    vt Repository record for Modeling and Experimental Analysis of Piezoelectric Augmented Systems for Structural Health and Stress Monitoring Applications (opens in a new tab)

  16. Localização de danos estruturais utilizando ondas guiadas e impedância eletromecânica

    … compared, namely the Guided Wave method and the Electromechanical Impedance (EMI) technique, applied to an experimental prototype of an aluminum plate representing a cut of an airplane wing. For this, algorithms implemented in the Labview software are used, which enabled the measurement of the …

    brazil-ufscar Repository record for Localização de danos estruturais utilizando ondas guiadas e impedância eletromecânica (opens in a new tab)

  17. Composite Structural Health Monitoring With Piezoelectric Wafer Active Sensors

    … on composites using wave propagation as well as electromechanical impedance spectroscopy methods. The damage studied includes both material level damage and structural level damage. The self-diagnosis capability of the sensor has also been developed in this study.

    south-carolina Repository record for Composite Structural Health Monitoring With Piezoelectric Wafer Active Sensors (opens in a new tab)

  18. INTELLIGENT DETECTION OF BOLT LOOSENESS USING STRUCTURAL HEALTH MONITORING METHODS AND PERCUSSION APPROACH

    … looseness, including the active sensing method, electromechanical impedance (EMI) method, and the vibro-acoustic modulation (VAM) method. However, current approaches mostly focus on single-bolt looseness detection, and there is still a lack theoretical investigation to explore the principle of …

    houston Repository record for INTELLIGENT DETECTION OF BOLT LOOSENESS USING STRUCTURAL HEALTH MONITORING METHODS AND PERCUSSION APPROACH (opens in a new tab)

  19. A Comprehensive Integrity Monitoring System for Bolted Flange Connections

    … The piezo-based active sensing method and the electromechanical impedance (EMI) method provide different approaches to monitor the characteristic variations in the metal-to-metal sealing condition. Upon seal failure, the acoustics generated by the sudden release of the escaping pressurized …

    houston Repository record for A Comprehensive Integrity Monitoring System for Bolted Flange Connections (opens in a new tab)

Page 1 of 2