Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 63 for “"Electrometer"”.

  1. Optomechanical electrometer based on optical mode-localization sensing

    … explores the feasibility of the optomechanical electrometer based on a novel sensing mechanism named optical mode-localization that originates from the mechanical mode-localization sensing mechanism. The electrometer is constructed by integrating coupled optical ring resonators and a suspended …

    soton Download PDF for Optomechanical electrometer based on optical mode-localization sensing (opens in a new tab)

  2. Absolute-potential measurements by means of the quadrant electrometer

    Thesis (M.S.)--University of Kansas, Chemistry, 1922. ; Includes bibliographical references.

    ku Repository record for Absolute-potential measurements by means of the quadrant electrometer (opens in a new tab)

  3. A wide-range logarithmic electrometer with improved accuracy and temperature stability

    … seven-decade temperature-compensated logarithmic electrometer is presented. The amplifier is designed for a dynamic range of 1 pA to 10 μA. Temperature compensation is accurately achieved by using an array of four matched monolithic bipolar transistors and straightforward postprocessing …

    ut-knoxville Repository record for A wide-range logarithmic electrometer with improved accuracy and temperature stability (opens in a new tab)

  4. An Electrometer Design and Characterization for a CubeSat Neutral Pressure Instrument

    … of an ionization chamber and a logarithmic electrometer circuit. The Rev. 1 SNeuPI electrometer prototype does not function as designed. A Rev. 2 electrometer circuit must be designed and its performance characterized across specified operating temperature and input current ranges. This …

    vt Repository record for An Electrometer Design and Characterization for a CubeSat Neutral Pressure Instrument (opens in a new tab)

  5. Highly Sensitive Single Electron Box on the Atomic Force Microscopy Probe as an Electrometer

    … of a highly sensitive single-electron box (SEB) electrometer integrated with atomic force microscopy (AFM) for charge and potential measurements at the nanoscale. The research addresses the limitations of traditional scanning single-electron transistor (SSET) techniques, which, despite their high …

    texas-state Repository record for Highly Sensitive Single Electron Box on the Atomic Force Microscopy Probe as an Electrometer (opens in a new tab)

  6. Scanning Electrometer for Electrical Double-layer (SEED) : The direct measurement of ion dynamics for biosensor

    … reaction. The method is called Scanning Electrometer for Electrical Double-layer (SEED). As the optical signal measured by SEED is linearly proportional to the maximum redox current obtained by CV, the optical signal quantitatively maps the local redox current density distribution. To …

    nebraska Repository record for Scanning Electrometer for Electrical Double-layer (SEED) : The direct measurement of ion dynamics for biosensor (opens in a new tab)

  7. The fluxgate electric field meter : a feasibility study

    … difference between the electrodes requires an electrometer with extremely low bias current and high input resistance. A novel electrometer was concieved and designed to accomplish this task. The new electrometer is a solid-state analogue of the vibrating-capacitor electrometer and is claimed to …

    ubc Repository record for The fluxgate electric field meter : a feasibility study (opens in a new tab) Download PDF for The fluxgate electric field meter : a feasibility study (opens in a new tab)

  8. Atsparus perkrovoms elektrometrinis stiprintuvas /

    … As technology constantly evolves, so does electrometers. There is a need to achieve high sensitivity of this device as it is used in high variety of scientific experiments. To improve sensitivity various amplifiers are used with field effect tranzistors and currently the most popular of …

    vilnius Repository record for Atsparus perkrovoms elektrometrinis stiprintuvas / (opens in a new tab)

  9. Development of novel fabrication technology for SOI single electron transfer devices

    … spin qubits co-integrated with a single electron electrometer, a waveguide and a nanomagnet. This platform aims to demonstrate the full operation of double spin qubits by integrating the following three key techniques in one compact footprint: a precisely controlled single electron transfer …

    soton Download PDF for Development of novel fabrication technology for SOI single electron transfer devices (opens in a new tab)

  10. Adaptive binarization of legacy ionization chamber cosmic ray recordings

    … ray ionization chamber which uses a Lindemann electrometer. Seven of these chambers were constructed at seven stations around the world. These chambers recorded cosmic ray data by projecting the shadow of the electrometer needle onto a continuously moving strip of 60 mm photographic paper. Hour …

    nwu-za Repository record for Adaptive binarization of legacy ionization chamber cosmic ray recordings (opens in a new tab)

  11. The Construction and Testing of an Ionization Chamber Designed for Use in Measuring the Roentgen Intensity of an X-ray Source

    … chamber, which, when connected to a Dershem electrometer, could be used to determine the intensity of an X-ray source producing ionization within the chamber. It was desired that the chamber conform to the physical dimensions of the ionization intensity unit, commonly called the “Roentgen".

    marquette Repository record for The Construction and Testing of an Ionization Chamber Designed for Use in Measuring the Roentgen Intensity of an X-ray Source (opens in a new tab)

  12. The detection of distant objects by means of infra-red radiation

    … type pentodes 954 and 956 have been examined as electrometer tubes in the region of grid current of 10⁻¹² amperes. It is indicated, on the basis of the small sample used, that the 954 is the better tube for this purpose.

    ubc Repository record for The detection of distant objects by means of infra-red radiation (opens in a new tab) Download PDF for The detection of distant objects by means of infra-red radiation (opens in a new tab)

  13. Holographic Deflection Imaging Measurement of Electric Charge on Aerosol Particles

    … a bipolarly charged particle sample against an electrometer, and the other to demonstrate particle size effect on triboelectric charging of aerosols in a fan-driven isotropic turbulence chamber. The HDI setup was configured for each experiment, and measurement uncertainty was estimated. …

    buffalo Repository record for Holographic Deflection Imaging Measurement of Electric Charge on Aerosol Particles (opens in a new tab)

  14. Die versyfering van historiese kosmiese straal-data = The digitization of historic cosmic-ray data

    … ionization chamber which uses a Lindemann electrometer. The shadow of the electrometer needle was projected onto a continuously moving strip of 60 mm photographic paper. Hour markers were recorded by dimming the lamp for three minutes at the start of each hour, while also grounding the …

    nwu-za Repository record for Die versyfering van historiese kosmiese straal-data = The digitization of historic cosmic-ray data (opens in a new tab)

  15. Design, Construction and Test of Ionization Chamber and Indicator Unit

    … by itself but also in conjunction with a Dershem Electrometer as the indicating unit. The unit was designed for use in x-ray diffraction and radioactivity experimentations. The chamber is so designed and constructed that it may be used with various gases under pressures up to forty pounds gage …

    marquette Repository record for Design, Construction and Test of Ionization Chamber and Indicator Unit (opens in a new tab)

  16. Development of a scanning thermoelectric microscope for profiling the local Seebeck coefficient in a thin-film superlattice

    … to connect the STM tip and the sample to an electrometer for measuring the thermovoltage generated by the contact of the STM tip to the warm sample. This method was used to measure the local Seebeck coefficient in each of the 20 layers of a p-type AlAs/GaAs thin-film superlattice. The results …

    texas Repository record for Development of a scanning thermoelectric microscope for profiling the local Seebeck coefficient in a thin-film superlattice (opens in a new tab) Restricted access

  17. Engineering the electromagnetic environment in a nanostructure to study single-electron tunneling

    … frequency Single Electron Transistor as a fast electrometer, single electron tunneling oscillations may therefore be directly observed.

    rice Repository record for Engineering the electromagnetic environment in a nanostructure to study single-electron tunneling (opens in a new tab)

Page 1 of 4