Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 44 for “"Electromyograms"”.
-
Acquisition and Analysis of Electromyograms of the Human Masseter Muscle
The electromyograms from the human masseter muscles of a randomly sampled population were obtained. For each of the 19 volunteers, four data records were taken during four different mechanical activities: a 20 mm bite separation sequence, a 2 mm bite separation sequence, a clenching sequence, and a …
-
An Instrumentation System for EMG Acquisition and Analysis of Upper Extremity Electromyograms in Cerebral Palsy Subjects
The quantification and analysis of electromyograms in abnormal subjects, such as Cerebral Palsy patients, can prove to be a useful diagnostic tool and aid to clinical treatment. It is the analytical goal of this project to inspect the EMG time and frequency domain characteristics of the forearm …
-
An investigation of the surface electromyograms spatial distribution of the pectoralis major muscle during flat and inclined bench press exercises
… elbow joint flexed at 100° and at 0°. Electromyograms (EMGs) were detected with a dry array of 16 electrodes parallel to the PM fibres. Shifts in IZ position ranged from 0.5 cm to 3.5 cm across all subjects over the detection sites. For the second study, we investigated the distribution …
-
Electromyographic, strength, and girth alterations in selected male and female subjects consequent to a seven week strength improvement program
… determine the test-retest reliability of surface electromyograms, cable tensiometer readings, and thigh measurements; (2) to determine if there was a statistically significant difference between the original and final measures of quadriceps strength, girth, and electromyograms following a strength …
-
Electromyographic Analysis of the Temporal and Masseter Muscles during the Para-Retentional Period in Orthodontic Patients
… (4) one day following occlusal equilibration. Electromyograms from the orthodontic group of subjects were compared with electromyograms from a group of subjects with normal occlusion, and a group of subjects with untreated Class II, Division 1 malocclusions. There was a total of thirteen …
-
A Study on the Effects of Diffuse Transcranial Electrical Currents Upon Unit and Population Visual Potentials
… and visual systems, on electroencephalograms and electromyograms, and electromyograms, and on heart rate and respiration.
-
Risk Factors in Headache and Temporomandibular Dysfunction
… locus of control, type-A, and hostility) and electromyograms (EMG) were compared. Laboratory stress (anagram task) was used while recording EMG. The data were analyzed using a discriminate function analysis which showed that a combination of psychological variables discriminates between groups …
-
NANOCOMPOSITE BIOELECTRONICS FOR BIOPOTENTIAL ENABLED PROSTHESIS
… a high-fidelity measurement of non-invasive electromyograms on the skin for advanced human-machine interface, targeting prosthesis.
-
Recording properties of a concentric needle electrode for electromyography as measured in an electrolytic tank model
… widely used concentric needle electrode produces electromyograms that do not exactly correspond to the true signal in the muscle. The presence of the electrode induces distortions of the original field distribution in the muscle, and the cannula does not act as a perfect reference electrode of …
-
Reflexes elicited by per-cutaneous stimulation of the medial and lateral ligaments of the knee
… The reflexes were observed in averaged rectified electromyograms from Rectus Femoris, Vastus Medialis, Vastus Lateralis, Lateral and Medial Gastrocnemius and Soleus. Muscle activity was essential if reflexes were to be elicited. No reflexes were elicited in relaxed muscles. During the first series …
-
Inspiratory muscle recruitment during swallow and a comparison across airway behaviors.
… augmented breath would be significantly larger. Electromyograms (EMG) from the costal diaphragm and parasternal muscles were recorded and analyzed in five freely breathing anesthetized cats. Muscle recruitment was examined by taking both the root mean square over the initial 75 ms (RMS75) of each …
-
Dominant Upper Extremity Kinematics and Muscular Activity in Sonographers during Kidney Scanning
… published limits during all scans. The electromyograms indicated that the agonistic muscles in the upper arm and forearm were activated simultaneously with the antagonistic muscles at multiple instances throughout the scans, indicating co-contraction was regularly occurring.
-
Quantifying Muscle Fatigue for Hypertrophy Based Exercise Using a Time Constant
… aim is to quantify muscle fatigue by examining Electromyograms of healthy individuals who are subjected to a long term, periodic hypertrophy based exercise routines using a consistent load. It will be demonstrated that a time-constant can be constructed to measure progress of muscle activity …
-
Insights gained into eccentric exercise-induced muscle damage from high-density surface electromyography
… and distally from biceps; recording of surface electromyograms with a 64- electrodes grid while 10 supramaximal pulses were applied to the musculocutaneous nerve; two isometric, maximal voluntary elbow flexion contractions (MVCs). The innervation zone (IZ) longitudinal location, the number of …
-
Reflex Response to Imposed Bilateral Hip Oscillations in Human Spinal Cord Injury
… position using instrumented leg braces. Surface electromyograms (EMGs) and joint torques were recorded during the imposed hip oscillations. Tests were conducted at two different frequencies to test for velocity-dependence of the reflexes and the following four tests were used to examine the …
-
Effects of beta-hydroxy beta-methylbutyrate (HMB) supplementation on gluteus medius muscle fiber composition and muscle performance in adult Thoroughbred horses exercising to fatigue on a high-speed treadmill
… femoris (BF) and semitendinosus (ST) surface electromyograms, and fore- and hindlimb metacarpophalangeal joint angles were captured for the duration of the SET. Results demonstrate that HMB supplementation increased (P < 0.05) the percentage of type IIA muscle fibers in the GM with a …
-
Low Impedance, Durable, Self-Adhesive Hydrogel Epidermal Electrodes for Electrophysiology Recording
… and stable recordings in electrocardiograms and electromyograms without the need for external fixatives, and maintaining functionality in humid and submerged environments. In addition, this study provides insight into the potential of hydrogel epidermal electrodes as mechanical sensors, expanding …
-
The effect of age on electromyographic and kinematic responses to electrical stimulation of the distal tibial nerve during walking
… and older adult (70 years and older) groups. Electromyograms (EMG) of the tibialis anterior (TA), soleus (SOL), medial gastrocnemius (MG), biceps femoris (BF) and vastus lateralis (VL) were recorded along with gait kinematics including angular displacement and velocity at the ankle and knee …
-
Investigation of the Neuromuscular Control of the Shoulder When Performing Concurrent Upper Extremity Tasks
… study provided an improved method of normalizing electromyograms from dynamic contractions and was used in the subsequent studies of this thesis. Studies 3 and 4 of this thesis examined the response of shoulder muscles in healthy individuals during static sub-maximal efforts and maximal dynamic …
-
The effect of age on neuromechanical responses to electrical stimulation of superficial peroneal nerve during walking
… walking in healthy young and elderly groups. Electromyograms (EMG) of the tibialis anterior (TA), soleus (Sol), medial gastrocnemius (MG), biceps femoris (BF) and vastus lateralis (VL) were recorded along with gait kinematics including joint displacement and angular velocity at the ankle and …
Page 1 of 3