Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 13 of 13 for “"Electron Radiotherapy"”
-
Monte Carlo techniques for electron radiotherapy
In this work simulation of electron beams and electron postmastectomy radiotherapy are evaluated using Monte Carlo Techniques. To achieve this several steps were followed. The first step was to perform measurements for dose distributions on a water tank for the different energies and field sizes …
-
Targeted Auger Electron Radiotherapy of HER2-amplified Breast Cancer
… sequences (NLS) and labeled with Auger electron-emitters have great potential for targeted radiotherapy of cancer. This approach may be especially appropriate for the 25-30% of patients with breast cancer whose tumors display overexpression of HER2. Trastuzumab (Herceptin) is a humanized …
-
Monte Carlo treatment planning with modulated electron radiotherapy: framework development and application
… de faisceaux combinés (MBRT pour "Mixed Beam RadioTherapy"). La justification et la validation de ce travail sont déemontrées à travers les résultats des études de planification, qui ont déterminées les avantages dosimétriques d'utiliser MERT ou MBRT par rapport aux alternatives cliniques de …
-
Monte Carlo Studies in the Applications of Magnetic Fields to Electron Radiotherapy
In electron radiation therapy, conforming the radiation dose to the tumor is important, yet challenging due to electron scatter by air molecules. The conventional approach involves placing a fixed metal collimator near the patient’s skin to block scattered radiation, providing a static treatment. …
-
Near Critical Density Laser Beat-Wave Acceleration for Radiotherapy Applications
… Density (NCD) plasma to generate an electron beam suitable for radiotherapy. The beat-wave is generated from the co-propagation of an 800nm laser, the primary laser, and a 400nm laser, the secondary laser. The lasers are simulated with a pulse duration of 35 fs and a respective energy …
-
Validation of a Monte Carlo dose calculation algorithm for clinical electron beams in the presence of phantoms with complex heterogeneities
… is to validate the Monte Carlo algorithm for electron radiotherapy in the Eclipse™ treatment planning system (TPS), and to compare the accuracy of the Electron Monte Carlo algorithm (eMC) to the Pencil Beam algorithm (PB) in Eclipse™. Dose distributions from GafChromic™ EBT3 film measurements …
-
Efeito de campos magnéticos estáticos em irradiação por elétrons
The present work deals with electron radiotherapy coupled with high external static magnetic fields and the biological response of cells to these. The objective was to determine the relevance of the coupling of external magnetic fields and radioactive beams as an optimization tool in the treatment …
-
Nyström method applied to the transport equation in cylindrical geometries
… of semitransparent materials, and photon and electron radiotherapy. The numerical simulation of this equation tends to be very difficult and the computational complexity arising from the high number of dimensions in the phase space and from its integro-differential structure leads to the …
-
Evaluation of Presage® As A 3D Dose Verification to ol In Proton Beams
Radiotherapy techniques have advanced and radiation dose plans have become much more complex over the last decade. This is especially true in proton therapy, which involves extremely steep dose gradients as a result of positioning the Bragg peak to cover the volumes to be treated. The Bragg peak …
-
Design and Validation of a Prototype Collimation System with Reduced Applicator Weights for Elekta Electron Therapy Beams
The objective of this study was to design an electron collimation system for Elekta Infinity accelerators with significantly reduced applicator weights, while maintaining acceptable in-field beam flatness and out-of-field leakage dose. The design was restricted to 6-20 MeV beams for 6x6 to 25x25 …
-
Cerenkov emission in radiotherapy
… assurance (QA) method is explored for clinical electron beams and clinical proton beams based on imaging and measuring Cerenkov light. A simulation was performed of the deposited energy and of Cerenkov production in water using Geant4. Monte Carlo simulation was used to predict the measured …
-
Design lineárního urychlovače pro onkologickou léčbu
Tématem této diplomové práce je design lineárního urychlovače pro onkologickou léčbu. Návrh je zaměřen na vylepšení estetické stránky stroje, ale zároveň přichází s invenčním řešením, jak lépe zpřístupnit ozařování onkologicky nemocných pacientů a tím tam zvýšit šance na úspěšnou léčbu rakoviny.