Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"Electron contamination"”.

  1. Experimental verification of buildup region dose calculation for a commercial treatment planning system

    … distances. This is attributed to the high electron contamination associated with these fields. The low levels of discrepancies between measured and calculated dose values for the 15 MV beam as compared to those of the 6 MV beam need further investigations. The good agreement between …

    sask Repository record for Experimental verification of buildup region dose calculation for a commercial treatment planning system (opens in a new tab)

  2. Optimization studies of the TRIUMF biomedical pion beam

    … decay, a model has been made to account for the electron contamination measurements. An optimum π⁻ production target for radiotherapy is recommended. We conclude that the actual performance of the pion transport system is approximately three times below the design expectation. However, the …

    ubc Repository record for Optimization studies of the TRIUMF biomedical pion beam (opens in a new tab) Download PDF for Optimization studies of the TRIUMF biomedical pion beam (opens in a new tab)

  3. Absorbed dose in the build-up region in modern megavoltage photon radiotherapy

    … mode is nearly compensated by the reduction of electron contamination and head scatter. In literature, the reduction in electron contamination in flattening-filter free mode is often anticipated to improve build-up calculation accuracy, as treatment planning systems generally use simple electron …

    ghent Repository record for Absorbed dose in the build-up region in modern megavoltage photon radiotherapy (opens in a new tab)

  4. A coarse mesh transport method with novel source treatment

    … angular distribution, spectrum, energy, and electron contamination of a 6 MV photon beam from a Varian c-series clinac. Of note is the use of a hemispherical harmonic expansion with the functional expansion tally method to model photonic fluence. The source was implemented in the COMET-PE …

    gatech Repository record for A coarse mesh transport method with novel source treatment (opens in a new tab)

  5. Operation, characterisation & physical modelling of unflattened medical linear accelerator beams and their application to radiotherapy treatment planning

    … surrounding their use. The photon scatter and electron contamination introduced by modifying the fluence are difficult to model, as is the variation in energy spectrum caused by differential absorption across the field. Leakage radiation also causes increased whole body doses to the patient, …

    birmingham Download PDF for Operation, characterisation & physical modelling of unflattened medical linear accelerator beams and their application to radiotherapy treatment planning (opens in a new tab)

  6. Real-time, upstream, radiotherapy verification using a CMOS Monolithic Active Pixel Sensor System

    … to separate therapeutic photon and contaminant electron signals. A grating-friendly reconstruction algorithm was developed, achieving worst resolutions of 68 . 59 ± 10. 75 μm for a 10 × 10 cm2 field and 109. 5 ± 24. 7 μm for a 40 × 40 cm2 field.<br/><br/>The system’s performance was validated …

    bristol Repository record for Real-time, upstream, radiotherapy verification using a CMOS Monolithic Active Pixel Sensor System (opens in a new tab) Download PDF for Real-time, upstream, radiotherapy verification using a CMOS Monolithic Active Pixel Sensor System (opens in a new tab)

  7. A quantitative method for reproducible ionization chamber alignment to a water surface for external beam radiation therapy depth dose measurements

    … radiation beam type, field size, energy, and electron contamination. Measurements are acquired using standard radiotherapy accelerators in the Virginia Commonwealth University Department of Radiation Oncology and at the National Research Council of Canada, where a customized scanning system …

    vcu Repository record for A quantitative method for reproducible ionization chamber alignment to a water surface for external beam radiation therapy depth dose measurements (opens in a new tab)

  8. In-Vivo Radiation Diode Dosimetry for Therapeutic Photon Beams

    … if sufficient buildup is provided to eliminate electron contamination. An empirical formula was proposed to fit the dose rate dependence of diode sensitivity. In the energy dependence study, the energy dependence diode detectors are quantified. The empirical theory to quantify this effect was …

    usf Repository record for In-Vivo Radiation Diode Dosimetry for Therapeutic Photon Beams (opens in a new tab)

  9. Ακριβής προσδιορισμός παραμέτρων ποιότητας δέσμης ακτινοβολίας στην ακτινοθεραπεία με τη βοήθεια επαναληπτικών υπολογιστικών μεθόδων monte carlo

    … 25 and 41, allowed us to study the influence of electron contamination in various therapeutic energies and in different geometries. The contribution of the secondary contamination electrons on the surface dose is 16% for 6 MV and 12 MV, 6% for 15 MV and 17% for 23 MV. The energy spectra of …

    greece Repository record for Ακριβής προσδιορισμός παραμέτρων ποιότητας δέσμης ακτινοβολίας στην ακτινοθεραπεία με τη βοήθεια επαναληπτικών υπολογιστικών μεθόδων monte carlo (opens in a new tab)

  10. Optimization of Beamline Elements and Shielding in a Preclinical MV Bremsstrahlung FLASH Irradiator

    … FLASH Effect has been shown to occur using electrons, protons, and low-energy photons (<600 keV), the underlying biological mechanism is still disputed. In order to obtain greater clarity regarding the biological mechanism, preclinical, experimental systems must be created with irradiation …

    gatech Repository record for Optimization of Beamline Elements and Shielding in a Preclinical MV Bremsstrahlung FLASH Irradiator (opens in a new tab)

  11. Dose calculations relating to the use of negative pi-mesons for radiotherapy

    … the detailed calculations, namely, (a) muon and electron contamination of the incident pion beam, (b) loss of pions from the beam by interactions with nuclei of the medium before coming to rest and (c) dose contributions from neutrons released in the "stars" at the end of the pion tracks. When …

    ubc Repository record for Dose calculations relating to the use of negative pi-mesons for radiotherapy (opens in a new tab) Download PDF for Dose calculations relating to the use of negative pi-mesons for radiotherapy (opens in a new tab)