Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 43 for “"Electron density and temperature"”

  1. Electron density and temperature determination of a laser-induced plasma in hydrogen gas

    <p>In dense plasmas that contain hydrogen, electron number densities can be deter- mined from the measured full widths at half maximum of the Balmer lines. Electron temperatures can be inferred from Boltzmann plots of the Balmer series. These techniques are applied to characterize the temporal …

    ut-knoxville Repository record for Electron density and temperature determination of a laser-induced plasma in hydrogen gas (opens in a new tab)

  2. Measurement of Electron Density and Temperature in Silicon Microplasma Devices by Optical Emission Spectroscopy

    Made available in DSpace on 2017-07-06T18:55:09Z (GMT). No. of bitstreams: 3 Li_Benben_MS.pdf: 998567 bytes, checksum: 7f27365b2d81cd9fa40c84426158d789 (MD5) Li_Benben_MS_ABS.pdf: 11136 bytes, checksum: 1c9a21b27d87b6b38a303fecf27b5f2e (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for Measurement of Electron Density and Temperature in Silicon Microplasma Devices by Optical Emission Spectroscopy (opens in a new tab)

  3. High-rate electron density and temperature of the ionospheric E-region derived through GNSS-optical sensor fusion

    … severely affect Global Positioning System (GPS) and other forms of wireless communication such as radio frequency (RF) and ultrahigh frequency (UHF). These effects are particularly prevalent at high latitudes, where auroral ionization patterns affect signals and low latitudes where plasma …

    bu Repository record for High-rate electron density and temperature of the ionospheric E-region derived through GNSS-optical sensor fusion (opens in a new tab)

  4. An Application of Spectroscopic Techniques to the Measurement of Electron Density and Temperature in a Brush Cathode Plasma

    A brief review of the Langmuir probe, microwave and spectroscopic techniques most commonly used to make measurements .of plasma electron temperature and density is presented. Of these various methods, certain spectroscopic methods are applied to the measurements of electron density and temperature …

    odu Repository record for An Application of Spectroscopic Techniques to the Measurement of Electron Density and Temperature in a Brush Cathode Plasma (opens in a new tab)

  5. Line broadening analysis of MPD thrusters

    … dynamic (MPD) thruster is conducted to determine electron density and temperature downstream from the cathode. H(Beta) line profiles were scanned from an argon-hydrogen plasma generated in the cathode test facility of the NASA Jet Propulsion Laboratory in Pasadena, CA. A computer program was …

    nps Repository record for Line broadening analysis of MPD thrusters (opens in a new tab)

  6. Magnetically stabilized helium arc for scattering experiments

    … investigated at filling pressures of 2 to 5 torr and plasma currents between 1 and 5 kA. Plasma parameters were measured at a magnetic field of 4 Teslas and a pressure of 3 torr. At these values of the magnetic field and the filling pressure the arc is steady and approximately cylindrically …

    ubc Repository record for Magnetically stabilized helium arc for scattering experiments (opens in a new tab)

  7. A two directional study of scattering of ruby laser light from a plasma jet

    … fluctuation. Changes in the plasma parameters, electron density and temperature, are ruled out as the source of the extra fluctuations.

    ubc Repository record for A two directional study of scattering of ruby laser light from a plasma jet (opens in a new tab)

  8. Spectroscopic measurement of n[subscript e] and T[subscript e] profiles using atomic and kinetic models for Argon in the Texas Helimak

    Profiles for electron density and temperature were determined in a self-consistent way using line emission spectroscopy and collisional radiative models for neutral and singly ionized Argon (Ar I and Ar II) in the Texas Helimak. Neutral Argon density profiles were calculated using a kinetic gas …

    texas Repository record for Spectroscopic measurement of n[subscript e] and T[subscript e] profiles using atomic and kinetic models for Argon in the Texas Helimak (opens in a new tab)

  9. Electron temperature and density measurements in a low pressure plasma with toroidal field

    Double probe measurement of electron temperature and density have been made in hydrogen and helium afterglows in the, pressure range from 1.0 to 60 microns Hg. in the presence of a toroidal magnetic field. Criteria for proper probe operation in the magnetic field have been proposed and followed …

    sask Repository record for Electron temperature and density measurements in a low pressure plasma with toroidal field (opens in a new tab)

  10. Evolution of Electron Properties After Nanosecond Repetitively Pulsed Discharges in Air Measured by Thomson Scattering

    … discharges in air by measuring the evolution of electron density and electron temperature between pulses using Thomson scattering of laser light. Bursts of repetitive pulses within several microseconds after the initial pulse were found to exhibit a coupling effect and create an even higher …

    ohiolink Repository record for Evolution of Electron Properties After Nanosecond Repetitively Pulsed Discharges in Air Measured by Thomson Scattering (opens in a new tab)

  11. Langmuir probe for electro-cyclotron-resonance plasmas

    … film on a substrate has been researched and employed in the semiconductor industry for decades. Recently, the technique of using an electron-cyclotron-resonance plasma to deposit a thin film on the substrate has been developed which has the advantage of easily controlling the electron …

    ttu Repository record for Langmuir probe for electro-cyclotron-resonance plasmas (opens in a new tab)

  12. Diagnostics in a high density Z pinch plasma

    … optical probe techniques. Simple streak and shadow methods give an important preliminary view of the spatial distribution and radial dynamics of plasma during the high compression phase. The electron density and temperature are determined as a function of time by spectrally resolving the …

    ubc Repository record for Diagnostics in a high density Z pinch plasma (opens in a new tab)

  13. Pressure broadening of SiI lines in a hydrogen plasma jet

    … was homogeneous in cross section with respect to electron density and temperature, with axial gradients, well suited for broadening experiments. The broadening of two Sil lines, X3905 Å and A2881 Å was studied. Widths and shifts due to broadening by electrons (Stark effect) and also by neutral …

    ubc Repository record for Pressure broadening of SiI lines in a hydrogen plasma jet (opens in a new tab)

  14. Experimental investigations of plasmas in electromagnetic shock tubes

    … have previously been studied in this laboratory and elsewhere. In general the temperatures and electron densities deduced from time-resolved spectra emitted by the plasma do not agree with the values calculated from shock theory. Photographs taken with a Kerr cell shutter revealed that luminous …

    ubc Repository record for Experimental investigations of plasmas in electromagnetic shock tubes (opens in a new tab)

  15. Diffusion and drift losses and electron cooling in helium afterglows confined by a toroidal magnetic field

    This thesis describes theoretical and experimental investigations of the decay of electron density and temperature in an afterglow confined by a toroidal magnetic field. Measurements were carried out in helium afterglows by means of double floating probes. The plasma density was high enough so that …

    sask Repository record for Diffusion and drift losses and electron cooling in helium afterglows confined by a toroidal magnetic field (opens in a new tab)

  16. A Neutral Beam Probe for the Helimak plasma experiment

    … After some fraction of the atoms underwent electron impact ionization, the resulting ion beam followed a path to an energy analyzer where the change of energy was detected along with the total ion current. The measurement of the change of energy implies a change of potential energy at the …

    texas Repository record for A Neutral Beam Probe for the Helimak plasma experiment (opens in a new tab)

  17. Development Of Laser Spectroscopy For Elemental And Molecular Analysis

    Laser-Induced Breakdown Spectroscopy (LIBS) and Raman spectroscopy are still growing analytical and sensing spectroscopic techniques. They significantly reduce the time and labor cost in analysis with simplified instrumentation, and lead to minimal or no sample damage. In this dissertation, …

    ucf Repository record for Development Of Laser Spectroscopy For Elemental And Molecular Analysis (opens in a new tab)

  18. Analysis of Cassini plasma and magnetic field measurements from 1-7 AU

    … then it has performed four planetary swing-bys and collected hundreds of days of data in the solar wind. In this thesis we mainly use data from the Cassini Electron Spectrometer (ELS) to discuss low energy electron distributions observed from 1 to 7 AU, and during the Cassini swing-bys of Earth …

    ucl Repository record for Analysis of Cassini plasma and magnetic field measurements from 1-7 AU (opens in a new tab)

  19. Ultraviolet sources for advanced applications in the vacuum UV and near UV

    … study consisting of experimental investigations and theoretical analyses of intense ultraviolet sources in VUV and near-UV. Some engineering issues regarding two prototypes of electrodeless lamps using rf and microwave are discussed.;Various excimers that produce intense UV light are …

    wm-mary Repository record for Ultraviolet sources for advanced applications in the vacuum UV and near UV (opens in a new tab)

  20. Study and reduction of the matrix effects in analytical ICP mass spectrometric measurements /

    … But the relationships between the signals and the quantity of element in the sample are very complicated, depend on many physical phenomena and chemical reactions and must be calibrated by application of the reference materials. The accuracy of analysis depends on the level of agreement …

    vilnius Repository record for Study and reduction of the matrix effects in analytical ICP mass spectrometric measurements / (opens in a new tab)

Page 1 of 3