Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 29 for “"Electron detector"”.

  1. Calibration & optimization procedures for an ultrafast DEPFET based electron detector (EDET)

    HLL und MPSD entwickeln einen neuartigen Elektronen-Detektor, der mit einer bis-lang unerreichten Bildfrequenz von 80 kHz, schnell ablaufende biologische und chemi-sche Prozesse aufzeichnen wird. Maßgefertigt für die Fokalebene eines Transmissi-onselektronenmikroskops, sollen verschiedenste Proben …

    lmu-germany Repository record for Calibration & optimization procedures for an ultrafast DEPFET based electron detector (EDET) (opens in a new tab)

  2. The design of a rocket-borne high time resolution electron detector

    … then act in resonance with precipitating auroral electrons at their local plasma and cyclotron frequencies (.5-10 MHz) to produce a modulation of the electron flux. The design of a rocket-borne experiment to measure flux modulation of 4-8keV auroral electrons in the previously unexplored frequency …

    rice Repository record for The design of a rocket-borne high time resolution electron detector (opens in a new tab)

  3. Development of an energy filtering direct electron detector for diffraction studies in the SEM

    … of an energy filtering digital direct electron detector for diffraction studies of materials in the field emission scanning electron microscope (SEM). The main aim was the development of the digital complementary metal-oxide-semiconductor hybrid pixel detector, \Timepix" for electron …

    strathclyde Repository record for Development of an energy filtering direct electron detector for diffraction studies in the SEM (opens in a new tab)

  4. Thermal analysis and performance validation for in-vacuum operation of Compton HV-MAPS electron detector for the MOLLER Experiment

    … by the scattering of longitudinally polarized electrons off un- polarized electrons in a liquid hydrogen target. MOLLER will utilize High Voltage-Monolithic Active Pixel Sensors (HV-MAPS) in the Hall A’s Compton polarimeter to monitor the polariza- tion of the incoming beam from the Continuous …

    manitoba Repository record for Thermal analysis and performance validation for in-vacuum operation of Compton HV-MAPS electron detector for the MOLLER Experiment (opens in a new tab)

  5. Feasibility Studies of Conversion Electron Mossbauer Spectroscopy (CEMS) of Iron-Doped InP

    An electron detector for conversion electron Mossbauer spectroscopy (CEMS) has been designed and built. Tests have been performed to study the effects on the electron detector resolution with respect to high anode voltage, He/CH4 gas flow rate, and counting rate. These parameters have been …

    odu Repository record for Feasibility Studies of Conversion Electron Mossbauer Spectroscopy (CEMS) of Iron-Doped InP (opens in a new tab)

  6. Electron Emission from Ferroelectric Thin Films and Single Crystals

    Electron emission from ferroelectrics (FEE) is a promising source for electrons. Although extensive studies have shown that the emission is inititated by a variation of the spontaneous polarization, the exact underlying emission process remained unclear to date. The focus of this work is to analyze …

    qucosa-diss

  7. The development of the plasma electron analyzer for the Comet Rendezvous and Asteroid Flyby Mission

    … of thirteen scientific instruments, a plasma electron analyzer capable of providing 3-dimensional measurements of the energy and angular distribution of electrons in the solar wind, asteroidal and cometary environments. After initial instrument selection, mission planners at JPL suggested that …

    rice Repository record for The development of the plasma electron analyzer for the Comet Rendezvous and Asteroid Flyby Mission (opens in a new tab)

  8. Detector development for the MOLLER experiment

    … in the scattering of longitudinally polarized electrons off unpolarized electrons, using the recently upgraded 11 GeV beam in Hall A at Jefferson Laboratory (JLab). The goal is to reach an overall accuracy of 2.4% for the measured APV, which would be an improvement of a factor of five compared …

    manitoba Repository record for Detector development for the MOLLER experiment (opens in a new tab)

  9. ELECTRON BEAM TESTING OF INTEGRATED CIRCUITS USING A MODIFIED SCANNING ELECTRON MICROSCOPE

    … frequencies and have smaller structures. The electron beam has been identified as the only usable alternative for probing VLSI devices. The electron beam is a easily positioned, high resolution, nonloading and nondestructive probe. A conventional scanning electron microscope (SEM) can be used …

    nus Repository record for ELECTRON BEAM TESTING OF INTEGRATED CIRCUITS USING A MODIFIED SCANNING ELECTRON MICROSCOPE (opens in a new tab) Download file for ELECTRON BEAM TESTING OF INTEGRATED CIRCUITS USING A MODIFIED SCANNING ELECTRON MICROSCOPE (opens in a new tab)

  10. Determination of the Neutron Beta-Decay Asymmetry Parameter <em>A</em> Using Polarized Ultracold Neutrons

    … the initial neutron spin and the emitted decay electron’s momentum, determines λ = gA /gV , the ratio of the weak axial-vector and vector coupling constants. A high-precision determination of λ is important for weak interaction physics, and when combined with the neutron lifetime it permits an …

    uky-thes Repository record for Determination of the Neutron Beta-Decay Asymmetry Parameter <em>A</em> Using Polarized Ultracold Neutrons (opens in a new tab)

  11. On the detection of two electrons in low-lying continuum states of a single projectile ion resulting from the collision of a 10.7 MeV AG4+ ion with an AR gas target

    … high energy doubly-excited states, in which two electrons are simultaneously excited away from the rest of the electrons in the ionic core, making their mutual interaction as important as their individual interaction with the remaining core. This thesis reports on an atomic collision experiment …

    ut-knoxville Repository record for On the detection of two electrons in low-lying continuum states of a single projectile ion resulting from the collision of a 10.7 MeV AG4+ ion with an AR gas target (opens in a new tab)

  12. Detection and Analysis of Low Energy Electrons in a Scanning Electron Microscope using a novel detector design based on the Bessel Box Energy Analyser

    Advancements in the field of scanning electron microscopy have been one of the major nano technology enablers. A scanning electron microscope (SEM) generates a magnified image of the sample by bombarding it with an electron beam and detecting the electrons that scatter off the surface along with …

    whiterose Download PDF for Detection and Analysis of Low Energy Electrons in a Scanning Electron Microscope using a novel detector design based on the Bessel Box Energy Analyser (opens in a new tab)

  13. Electronic and optoelectronic devices using chemical vapour deposited 2D materials

    … on playing important role in next generation electronics and optoelectronics. Driven by the thrust of this, this project studies the electronic and optoelectronic properties of 2D materials through device fabrication with 2D materials. Graphene and WS<sub>2</sub> are the representative 2D …

    oxford Repository record for Electronic and optoelectronic devices using chemical vapour deposited 2D materials (opens in a new tab)

  14. High-Throughput Structure Determination Using Serial Electron Diffraction Method

    … methods such as X-ray diffraction (XRD), or Cryo-Electron Microscopy (CryoEM) require well-ordered, micron-sized crystals and often involve cryogenic environments, limiting their applicability to many important classes of beam-sensitive or nanoscale materials. Electron diffraction has emerged as a …

    toronto-retro Repository record for High-Throughput Structure Determination Using Serial Electron Diffraction Method (opens in a new tab)

  15. Sounding rocket measurements of thermal electrons in active nightside aurora

    … in darkness were made by the UNH Thermal Electron Detector (TED). At these middle altitudes, understanding this population is important because the thermal electrons can carry currents coupling the lower ionosphere and the magnetospheric auroral source. This thesis, focusing on the …

    unh-thes Repository record for Sounding rocket measurements of thermal electrons in active nightside aurora (opens in a new tab)

  16. Phenotypic Plasticity of Oral Jaw Dentition in Archosargus Probatocephalus

    … sectioned, and examined using scanning electron microscopy (SEM) to measure the enamel and dentin layers. Using the SEM backscatter electron detector the elemental composition of the different layers was determined at multiple locations. Finally, data was analyzed using analyses of …

    wku-diss Repository record for Phenotypic Plasticity of Oral Jaw Dentition in Archosargus Probatocephalus (opens in a new tab)

  17. Development of a Low-Cost Electron Microscope for Educational Purposes

    Electron microscopy is a powerful tool for exploring microscopic world, yet its high cost and operational complexity severely limit accessibility, particularly within educational institutions. Commercial systems are often designed as opaque "black boxes," further hindering hands-on learning and …

    portland-state Repository record for Development of a Low-Cost Electron Microscope for Educational Purposes (opens in a new tab)

  18. Cryo-EM structure of IcmS-IcmW-DotL(655-783) from the type IVB secretion system of legionella pneumophila

    … studies by X-ray crystallography and cryo-electron microscopy. Three maps of the IcmSW-DotL-tail complex (~42 kDa) were generated from cryo-EM images recorded with a Volta phase plate and K2 Summit direct electron detector at 500-1000 nm under-defocus. The final maps were processed with …

    bu Repository record for Cryo-EM structure of IcmS-IcmW-DotL(655-783) from the type IVB secretion system of legionella pneumophila (opens in a new tab)

  19. Studies of the local atomic ordering in nanostructured amorphous materials using advanced scanning transmission electron microscopy techniques

    … are investigated using scanning transmission electron microscopy. One of the most powerful tools for achieving this is fluctuation microscopy, where a set of diffraction patterns are recorded using a small, but fairly parallel electron probe that is scanned over the sample using a small step …

    glasgow Repository record for Studies of the local atomic ordering in nanostructured amorphous materials using advanced scanning transmission electron microscopy techniques (opens in a new tab) Download PDF for Studies of the local atomic ordering in nanostructured amorphous materials using advanced scanning transmission electron microscopy techniques (opens in a new tab)

  20. Transmission Electron Microscopy of Organic Crystalline Material and Zeolites

    … of the fine atomic structure. In this work electron microscopy has been utilised for the characterisation of a model organic compound (theophylline form II) and a model zeolite (Sn-beta), both of which are highly sensitive to damage when irradiated by a high-energy electron beam (80 – 300 …

    whiterose Download PDF for Transmission Electron Microscopy of Organic Crystalline Material and Zeolites (opens in a new tab)

Page 1 of 2