Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 169 for “"Electron probe microanalysis."”

  1. A new absorption correction for quantitative electron-probe microanalysis.

    … aluminium and gold over a range (5-29 kV) of probe voltages. The measurements were carried out at three specimen tilt angles ( tau = 90°, 60°, and 40°), where tau is the angle between the incident electron beam and the specimen surface). φ(rhoz) profiles have also been calculated for the same …

    bath Repository record for A new absorption correction for quantitative electron-probe microanalysis. (opens in a new tab)

  2. Field Emission Gun Electron Probe Microanalysis of Radioactive Materials

    … aim of this study was to investigate low voltage microanalysis of radioactive (RA) materials. Field emission electron sources provide access to higher beam currents at smaller beam diameters down to lower accelerating voltages than tungsten sources. Surface layers rapidly contribute errors with …

    bristol Repository record for Field Emission Gun Electron Probe Microanalysis of Radioactive Materials (opens in a new tab)

  3. Quantitative electron probe microanalysis of light elements using energy dispersive x-ray spectrometry.

    … (ED) analysis of light elements in the electron probe are assessed, with particular concern for the accuracy which can be achieved in quantitative analysis. A comprehensive study of the ED system and the low energy spectrum it produces has revealed several problems. These have been …

    bath Repository record for Quantitative electron probe microanalysis of light elements using energy dispersive x-ray spectrometry. (opens in a new tab)

  4. Simulation And Modelling Of Thin Film Phi(rho-z) Curves For Electron Probe Microanalysis

    … analysis of homogeneous bulk unknowns using an electron probe microanalyzer requires the accurate knowledge of the depth distributions of x-ray production ({dollar}phi{dollar}({dollar}rho{dollar}z) curves). Straight line behaviour is observed in the plot of …

    uwo Repository record for Simulation And Modelling Of Thin Film Phi(rho-z) Curves For Electron Probe Microanalysis (opens in a new tab)

  5. The Controlled Solidification of Fe-Mn Base Alloys

    … Qualitative and quantitative metallography and electron-probe microanalysis were used to determine the solidification structure, dendrite arm spacings, solute concentration profiles and inclusion compositions. The results were interpreted in the light of existing knowledge and concepts …

    mcmaster Repository record for The Controlled Solidification of Fe-Mn Base Alloys (opens in a new tab)

  6. Sorption and diffusion of caesium in some nuclear graphites.

    … heat treatment, desorption programme by electron probe microanalysis. The desorption curves consisted of an initial fast period controlled by evaporation of caesium from the surface, followed by a slow rate, controlled by diffusion from the bulk of the graphite. The desorption curves were …

    bath Repository record for Sorption and diffusion of caesium in some nuclear graphites. (opens in a new tab)

  7. Effect of Solid State Diffusion on Microsegregation in Steels

    … effect of carbon on the morphology of growth. Electron probe microanalysis was carried out to obtain quantitative results on the microsegregation of Ni in the binary and ternary alloys. The extent of homogenization of Ni, occurring both during and after solidification was quantitatively …

    mcmaster Repository record for Effect of Solid State Diffusion on Microsegregation in Steels (opens in a new tab)

  8. Quantitative methods in electron microscopy.

    … correction programmes used in quantitative electron probe microanalysis are assessed and their limitations discussed. It is shown that the Philibert absorption correction models (Philibert 1963) may be significantly improved by the adoption of new expressions for the a and h terms. A new …

    bath Repository record for Quantitative methods in electron microscopy. (opens in a new tab)

  9. Redox conditions in the cratonic lithosphere and implications for metasomatism

    … Conventional petrologic techniques, along with electron probe microanalysis (EPMA) and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS), were used to characterise the samples and identify metasomatic events. Evidence of at least one such event was found in the Wesselton …

    anu Repository record for Redox conditions in the cratonic lithosphere and implications for metasomatism (opens in a new tab)

  10. Thermodynamic and Kinetic Study of the Iron-Manganese-Sulfur System at 1300°C

    … of formation of sulfides at 1300°C using electron probe microanalysis and metallographic techniques. Apparent semi-conductive behaviour of MnS, which cannot be understood on the basis of simple diffusion kinetics, was observed in the diffusion experiments. The concept of the "virtual" …

    mcmaster Repository record for Thermodynamic and Kinetic Study of the Iron-Manganese-Sulfur System at 1300°C (opens in a new tab)

  11. A Study Of The Opaque Minerals In The Whitestone Anorthosite, Dunchurch, Ontario

    … by chemical analysis, X-ray diffraction and electron probe microanalysis. A modification of the solvus shape in the hematite-ilmenite system consistent with the composition of hemo-ilmenite lamellae, as well as a mechanism for formation of metamorphic magnetite porphyroblasts from …

    mcmaster Repository record for A Study Of The Opaque Minerals In The Whitestone Anorthosite, Dunchurch, Ontario (opens in a new tab)

  12. High Strength Iron Compacts Containing Carbon, Copper and Tin

    … sintering in this system have been studied. Electron probe microanalysis of sintering models showed that the addition of tin to the iron-copper system progressively increased the solubility of iron in the liquid phase, and decreased the rate of copper diffusion into the iron. Likewise, the …

    aston Repository record for High Strength Iron Compacts Containing Carbon, Copper and Tin (opens in a new tab)

  13. The effect of misfit on morphology and kinetics of plate shaped precipitates

    … by 0.38% for Cu concentrations up to 0.51 at%. Electron probe microanalysis showed that the Mg atoms preferentially partition to the 7 phase whereas Cu atoms partition equally between the precipitate and matrix phases. Direct transmission election rnicroscope observations were made on the …

    ubc Repository record for The effect of misfit on morphology and kinetics of plate shaped precipitates (opens in a new tab)

  14. Cretaceous mantle of the Congo craton : evidence from mineral and fluid inclusions in Kasai alluvial diamonds

    … compositions of fibrous diamonds analyzed by electron probe microanalysis are moderately to highly silicic, matching compositions of diamond-forming fluids from other DRC diamonds. Regional homogeneity of Congo fibrous diamond fluid inclusion compositions suggests spatially extensive …

    ubc Repository record for Cretaceous mantle of the Congo craton : evidence from mineral and fluid inclusions in Kasai alluvial diamonds (opens in a new tab)

  15. Influence of High Temperature Creep upon the Structure of ß-NiAl and ß-NiAl(Fe) Single Crystals

    … controlling the chemical composition with the electron probe microanalysis, determining the unit cell contents from the combined lattice parameter and mass density measurements, and refining the structure parameters according to the X-ray reflection intensity. Specifically, two special single …

    qucosa-diss Repository record for Influence of High Temperature Creep upon the Structure of ß-NiAl and ß-NiAl(Fe) Single Crystals (opens in a new tab)

  16. Identification of tephras from the Eastern Mediterranean using solid state techniques

    … identify the minerals present in the materials, electron probe microanalysis (EPMA) to obtain the chemical composition of the glassy components, and scanning electron microscopy (SEM) to study the morphology of the glassy components. The materials from the Philippi peat basin were found to be …

    concordia

  17. Genesis of the Archaean Troilus Gold-Copper Deposit, Quebec. Evidence for a Multi-Stage, Mixed Genetic Origin

    … laboratory and synchrotron X-ray fluorescence, electron probe microanalysis, microthermometry, and quantitative fluid inclusion gas analysis mass spectrometry were used in support of this work. Results indicate a complex deposit genesis consisting of at least four distinct hydrothermal events …

    uwo Repository record for Genesis of the Archaean Troilus Gold-Copper Deposit, Quebec. Evidence for a Multi-Stage, Mixed Genetic Origin (opens in a new tab)

  18. Combined Geochemical, Mineralogical, and Structural Investigation of Auriferous Quartz Veins at the Vertigo Target, White Gold District, West-Central Yukon Territory, Canada

    … uses digital borehole logging, petrography, electron probe microanalysis, and micro-x-ray fluorescence to evaluate the spatial, geochemical, and mineralogical distribution of Au mineralization at the Vertigo target. Petrographic and structural interpretations are contextualized with …

    uwo Repository record for Combined Geochemical, Mineralogical, and Structural Investigation of Auriferous Quartz Veins at the Vertigo Target, White Gold District, West-Central Yukon Territory, Canada (opens in a new tab)

  19. Laser induced breakdown spectroscopy of martian breccia Northwest Africa 7034: comparison with Mars Science Laboratory results

    … results with the bulk composition acquired with electron probe microanalysis (EPMA) show agreement within LIBS instrument error. Comparison of NWA 7034 data with targets from Gale shows chemical and textural similarities. This study helps bridge the gap between Mars in situ and martian meteorite …

    unm Repository record for Laser induced breakdown spectroscopy of martian breccia Northwest Africa 7034: comparison with Mars Science Laboratory results (opens in a new tab)

Page 1 of 9