  1. Interpreting Electron Temperature Changes in the Lower Ionosphere

    The electron temperature changes due to 3, 5 and 430 MHz radio wave heating in the lower ionosphere are measured using incoherent scatter diagnostic techniques and are also calculated from heating/cooling theory. The experiments were performed at Arecibo Observatory using the new HF heating …

    rice Repository record for Interpreting Electron Temperature Changes in the Lower Ionosphere (opens in a new tab)

  2. Measurement of Electron Temperature and Density in a Reflex Discharge

    … with continuous, stable operation of the plasma. Electron temperature is measured through the use of spectroscopy, electrostatic wave propagation, and Langmuir Probes. An electron temperature in the 1 eV to 5 eV range is indicated. Electron density is measured through the observation of the …

    fau Repository record for Measurement of Electron Temperature and Density in a Reflex Discharge (opens in a new tab)

  3. Expansion and electron temperature evolution in an ultracold neutral plasma

    … vacuum. It presents a comprehensive study of the electron temperature evolution under different initial conditions. Ultracold neutral plasmas are created by photoionizing laser-cooled neutral atoms in ultrahigh vacuum. The ions are typically at a temperature of ∼ 1K while the electron …

    rice Repository record for Expansion and electron temperature evolution in an ultracold neutral plasma (opens in a new tab)

  4. Microwave Emission and Electron Temperature in the Maryland Centrifugal Experiment

    The use of two magnetised plasma waves as electron temperature diagnostics for the Maryland centrifugal ecperiment (MCX) are explored. First, microwave emission in the whistler mode is examined and ultimately found to be a poor candidate for diagnostic purposes owing to reflections from elsewhere …

    maryland Repository record for Microwave Emission and Electron Temperature in the Maryland Centrifugal Experiment (opens in a new tab)

  5. Electron temperature and pressure at the edge of ASDEX Upgrade plasmas

    … a new method for the estimation of accurate edge electron temperature profiles by forward modelling of the electron cyclotron radiation transport and demonstrates its successful application to investigate the impact of Magnetic Perturbation (MP) fields used for ELM mitigation on the edge kinetic …

    lmu-germany Repository record for Electron temperature and pressure at the edge of ASDEX Upgrade plasmas (opens in a new tab)

  6. Electromagnetic instabilities and plasma turbulence driven by the electron-temperature gradient

    … instabilities and turbulence driven by the electron-temperature gradient are considered in a local slab model of a tokamak-like plasma. Derived in a low-beta asymptotic limit of gyrokinetics, the model describes perturbations at scales both larger and smaller than the electron inertial …

    oxford Repository record for Electromagnetic instabilities and plasma turbulence driven by the electron-temperature gradient (opens in a new tab)

  7. Inference of ionospheric electron density and electron temperature profiles with regression methods

    In this thesis, the inference of ionospheric electron density profiles and electron temperature profiles is presented and discussed. The analysis is based on the Nearest Neighbor (NNB) and Radial Basis Function (RBF) regression methods. Synthetic data sets used to train and validate the inference …

    alberta Repository record for Inference of ionospheric electron density and electron temperature profiles with regression methods (opens in a new tab)

  8. Electron temperature gradient mode streamers and the end of the tokamak pedestal

    … thesis seeks to provide part of the answer via electron-temperature-gradient (ETG) fluctuations in the pedestal region of tokamaks, investigated with the Gyrokinetic Electromagnetic Numerical Experiment (GENE). While ETG turbulence is sometimes ignored, as it is very small scale, there may be …

    texas Repository record for Electron temperature gradient mode streamers and the end of the tokamak pedestal (opens in a new tab)

  9. Spectroscopic Measurement of the Electron Temperature in the Tenuous Argon Ion Laser Plasma

    … line intensity ratio technique for measuring the electron temperature was examined for an argon plasma with a "population inversion" i.e., the number of ions with electrons in the upper 4p levels was greater than in the lower 4s levels. The line intensities from these levels, the argon ion lasing …

    odu Repository record for Spectroscopic Measurement of the Electron Temperature in the Tenuous Argon Ion Laser Plasma (opens in a new tab)

  10. Electrostatic Probe Theory and Its Application to Electron Temperature and Density of Plasma

    … probe theory and its application to measure the electron temperature, the plasma density and the floating potential is the subject of this dissertation. After a general introduction and a brief discussion of the space-charge equations, the Langmuir probe theory is discussed rather extensively …

    bridgeport Repository record for Electrostatic Probe Theory and Its Application to Electron Temperature and Density of Plasma (opens in a new tab)

  11. Electron temperature and density measurements in a low pressure plasma with toroidal field

    Double probe measurement of electron temperature and density have been made in hydrogen and helium afterglows in the, pressure range from 1.0 to 60 microns Hg. in the presence of a toroidal magnetic field. Criteria for proper probe operation in the magnetic field have been proposed and followed …

    sask Repository record for Electron temperature and density measurements in a low pressure plasma with toroidal field (opens in a new tab)

  12. Non-Intrusive Optical Measurement of Electron Temperature in Near Field Plume of Hall Thruster

    … of non-intrusive optical techniques to measure electron temperature in the near field of a Hall thruster, a type of electric propulsion. Results indicate that the pursued technique may be of utility to providing a simple to set up and execute diagnostic for determining electron temperatures in …

    ohiolink Repository record for Non-Intrusive Optical Measurement of Electron Temperature in Near Field Plume of Hall Thruster (opens in a new tab)

  13. Laser Thomson scattering measurements of electron temperature and density in a Hall-effect plasma

    … HET technology is well developed but the electron properties in the discharge are not completely understood, mainly due to the difficulty involved in performing accurate measurements in the discharge. Measurements of electron temperature and density have been performed using electrostatic …

    mtu Repository record for Laser Thomson scattering measurements of electron temperature and density in a Hall-effect plasma (opens in a new tab)

  14. Electron Temperature Enhancement Effects on Plasma Irregularities Associated with Charged Dust in the Earth's Mesosphere

    … described by continuity and momentum equations, electrons whose behavior is determined from quasi-neutrality, and charged dust described by the standard Particle-In-Cell PIC method. The model has been used to investigate the temporal behavior of charged dust associated electron irregularities …

    vt Repository record for Electron Temperature Enhancement Effects on Plasma Irregularities Associated with Charged Dust in the Earth's Mesosphere (opens in a new tab)

  15. An attampt to measure the electron temperature of a Xenon Chloride excimer laser discharge plasma by Thomson scattering

    An electronic timing system was developed so that a commercial Nd:YAG regenerative amplifier could be triggered remotely with a BNC cable and pushbutton switch. This system was used to accurately time a Xenon Chloride transverse discharge laser to the short, high power Nd:YAG pulse to within 5 ns. …

    ubc Repository record for An attampt to measure the electron temperature of a Xenon Chloride excimer laser discharge plasma by Thomson scattering (opens in a new tab)

  16. Helium Line Emission Spectroscopy in the Prototype Material Plasma Exposure eXperiment for Evaluation of Electron Temperature and Density

    <p>The helium-line spectral monitoring (HELIOS) diagnostic measures T_e and n_e using a collisional radiative model (CRM) to interpret the relative intensity of neutral helium emission lines in the presence of plasma. The emission intensity can be measured at a data digitization rate of up to 1 MHz …

    utk-theses Repository record for Helium Line Emission Spectroscopy in the Prototype Material Plasma Exposure eXperiment for Evaluation of Electron Temperature and Density (opens in a new tab)

  17. Vibrational Energy Distribution, Electron Density and Electron Temperature Behavior in Nanosecond Pulse Discharge Plasmas by Raman and Thomson Scattering

    … N<sub>2</sub> vibrational distribution, electron temperature and electron density in nanosecond pulse, nonequilibrium plasma, electric discharges are studied through laser scattering diagnostic techniques. The experiments are conducted in high pulse energy (≥4 mJ/pulse), nanosecond pulse …