Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 83 for “"Electronic circuitry"”.
-
Electronic circuitry for shaping current pulses for small scale transcranial magnetic stimulation coils
… to simplify pulse shaping without using complex circuitry, a mosfet was used as a dynamic element to control current. A triangular gate voltage waveform was introduced. This approach allowed for finer control over critical parameters such as rise time, fall time, and pulse width, which are key to …
-
Resolving bacteria with the coulter counter
… and Proteus vulgaris were obtained with the electronic particle counter. These distributions appeared to follow the normal distribution when relative per cent was plotted against diameter, The two modes of the distributions appeared far enough apart to warrant future attempts to separate …
-
A digital tachometer/accelerometer
… through velocity- and acceleration-processing circuitry. Computer simulation is used to optimize the electronic circuitry to achieve the best accuracy.
-
A/D conversion: a digital voltmeter
… and large scale integration of commonly used electronic circuitry. One of the special MSI devices commercially available today is the Fairchild 381^ Digital Voltmeter Logic Array which contains most of the logic required for a 4 1/2 decade digital Voltmeter. In this thesis the design of an …
-
Acute Effects of the Antibiotic Streptomycin on Neural Network Activity and Pharmacological Responses
… serve as neural interfaces connecting neurons to electronic circuitry. The result of this study shows that streptomycin lowered the spike production of neuronal network, and also, sensitization was seen when neuronal network pre-exposed to streptomycin.
-
An Experimental Investigation of the Dead Time of Geiger-Mueller Counters
… importance. With the present perfection of electronic circuitry, this resolving time has become largely a function of the dead time of the Geiger counter tube itself. It was therefore proposed to investigate methods of reducing this dead time. Only self-quenching counter tubes had to be …
-
A visual display of certain speech parameters
… are established and discussed. The complete electronic and mechanical design and fabrication of a prototype speech parameter analyzer is described in detail. Schematic diagrams of all electronic circuitry employed and photographs of the prototype equipment are included. Preliminary …
-
An automatic electronic speech teaching responder.
… of this concept are presented, The complete electronic and mechanical design plus fabrication of the automatic electronic speech training responder is described in detail. Schematic diagrams of all electronic circuitry employed and photographs of the prototype equipment are included. The …
-
Shipboard More-Electric
… fields of digital control and advanced power electronic circuitry enable researchers and designers to investigate novel approaches of providing shipboard service power requirements. The Shipboard More-Electric concept is based on using high efficiency DC-DC PWM converter modules in place of …
-
Fluid manipulation by means of electrowetting-on-dielectrics
… thin films for EWOD was developed. Further electronic circuitry and software ("DHS") to control almost every EWOD application was built. Limitations of the effect (e.g. contact angle saturation) were investigated and the dynamics of a specific EWOD systems (open-EWOD) was examined. …
-
A high performance laser-excited interferometer for measuring electron densities
… cm⁻²) and temporal resolution (Δτ ~ ±25 nsec.). Electronic circuitry provides a direct, continuous readout of electron density. Measurements have been made on a z-pinch discharge which are impossible in any other way, confirming the usefulness of the discharge as a spectroscopic source, and …
-
Techniques to Improve Electron Density Measurements in the D Region of the Ionosphere
… of an antenna in a plasma, (2) by using improved electronic circuitry, and (3) by modifying the mechanical payload configuration. To use the improved model for antenna impedance, estimates for the earth's magnetic field, electron temperature, and electron collisional frequency are entered and then …
-
Design and Implementation of Signal Processing Circuitry for Implantable Sensors
… a chip containing the sensors and the electronic circuitry is implanted in the human body. This implanted chip provides for continuous measurement and helps reduce inconvenience caused to diabetic patients. A potentiostat forms an integral part of a sensor signal processing circuit. In …
-
Development of a power electronics for a flywheel energy storage system
The development of a power electronic circuitry for a flywheel energy storage system is discussed in the following aspects. First, due to the nature of permanent magnet brushless DC motor/generator, the operation of three-phase voltage source inverter/rectifier can be simplified to that of a …
-
Low Power Amplifiers for Recording Activity of Electrically Active Cells
… drives the need for the integration of low power electronic circuitry at or very close to the site of activity. We describe low voltage low power CMOS amplifiers that address this need by rejecting DC offsets, and have tunable bandwidths. They operate at 1.35V, with a power consumption of 37.8μW …
-
Pixel: A Tool for Creative Design with Physical Materials and Computation
… of practice, such as computer programming and electronic circuitry. Although recent tools have lowered barriers to creating such systems, they tend to be too technical and constraining for creating systems to be a feasible everyday activity. These tools often rely on traditional interaction …
-
Analysis and application of a passive electronic analog model to the hydrologic regime of a watershed
A digitally simulated electronic watershed analog has been developed for the analysis of the hydrologic regime of a watershed. Individual electrical circuits were designed to synthesize the physical characteristics of the hydrologic components of a watershed: interception, surface storage, runoff, …
-
Characterization of avalanche photodiode arrays for temporally resolved photon counting
… Lincoln Laboratory but with no accompanying electronic circuitry for biasing or reading out the detectors. I describe the design, construction and testing of the electronics to bias the arrays and detect photons. Once a final prototype version of the electronics was developed, I characterized …
-
The Effect of Cesium Vapor on the Emission Characteristics of Uranium Carbide at Elevated Pressures
… bath. The design of the tube is shown, and the electronic circuitry is given with an explanation of the method of measurement. The experimental data for “electron emission vs 1000/T” was plotted for the experimental μa’s and then used to make a plot of “log10 μa vs 1000/T”. The plot of “log10 μa …
-
Synthesis and High-Pressure Structural Studies of AuX2 (X= Al, Ga, In) Compounds
… to intriguing pressure-induced behavior such as electronic topological transitions (ETTs), and structural phase transitions as well as their use in a variety of practical applications such as a solar spectral absorber and in electronic circuitry. In this study, the high-pressure structure of …
Page 1 of 5