Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 6 of 6 for “"Electrooptical devices Design and construction"”.

  1. Polymeric beam-steering 1xN fiber-optic switch

    In Phase I of this research, we first designed, fabricated and demonstrated a thin-film polymeric thermo-optic waveguide beam deflector based on prism-array heating electrode, whose shape contour was designed to effectively steer the beam at maximal deflection. At 1310 nm, a beam deflection angle …

    texas Repository record for Polymeric beam-steering 1xN fiber-optic switch (opens in a new tab)

  2. Advancements in Slow-Wave Thin Film Lithium Niobate for Opto-Electronic Communications

    … in this dissertation are those of the author and do not reflect the official policy or position of the United States Air Force, Department of Defense, or the U.S. Government. The explosive growth of human connectedness over the previous decades has, and will continue to strain the …

    ucf Repository record for Advancements in Slow-Wave Thin Film Lithium Niobate for Opto-Electronic Communications (opens in a new tab)

  3. Analysis and Modification of an Electro-Oculometer

    This paper describes an electro-oculometer and analyzes the electronic circuits required to process the signal. This electro-oculometer is a passive, two-channel device which detects the eye orientation using commercially available electrodes attached near the eyes. The electro-oculometer is …

    ucf Repository record for Analysis and Modification of an Electro-Oculometer (opens in a new tab)

  4. Interfacing a Quadriplegic to a Computer Using the Electro-Ocumeter

    The purpose of this is to design an electro-oculometer system that paper will enable quadriplegics and other persons with severe physical disablities to use a computer. An electro-oculometer is a device that measures the position of a person's eyes. The vertical and horizontal movements of the eyes …

    ucf Repository record for Interfacing a Quadriplegic to a Computer Using the Electro-Ocumeter (opens in a new tab)

  5. Design of a bandpass oculometer

    … (CRP) generated by the eye. In this thesis, the Bandpass Oculometer replaces the joystick of a personal computer, allowing the viewer to use a computer simply by moving his eyes. Low frequency noise, present in all electronic circuits, produces an offset from the reference point, the center of the …

    ucf Repository record for Design of a bandpass oculometer (opens in a new tab)