Simulation and Optimization of ESA Designs for Space Plasma Missions
A novel electrostatic analyzer (ESA) simulation method that differs significantly from traditional methods is presented in this study, the "reverse-fly" simulation method. The simulation process and its applications are discussed in detail. This method is tested by comparing its results to the …
-
PART I. ANALYTICAL APPLICATIONS OF MASS SPECTROMETRY/MASS SPECTROMETRY (MS/MS). PART II. INVESTIGATIONS OF ION-MOLECULE REACTIONS PRODUCTS BY MS/MS. PART III. THE QUESTION OF TAUTOMERISM OF ALKYLNITRILE AND ISONITRILE RADICAL CATIONS
… (ms/ms) instrument having the configuration electrostatic analyzer, magnetic sector, and electrostatic analyzer (EBE). Suitable experiments are reported which evaluate the instrument in terms of the requirements for analytical ms/ms applications: high resolution mass selection, high dynamic …
-
A systematic study of backward ejected electrons for 1 MeV/u O ℓ (q = 3 - 8) projectile ions colliding with argon gas
… ions and argon atoms. A 30 ° parallel plate electrostatic analyzer is used for the measurements. The analyzer has been reconstructed and its properties have been investigated. A computer program has been written to simulate the operation of the analyzer. Within the electron energy range of …
-
Determination of SPEAR-1 rocket body potential during high-voltage experiments
… with respect to the rocket. This thesis uses the electrostatic analyzer ion data to determine the charging response of the rocket body. The peak potential was reached during a 45 kV sphere bias sequence resulting in a -17.4 kV rocket body potential at 361 km altitude. The rocket body potential …
-
Space Experiments Aboard Rockets: SPEAR III
… launch took place at the NASA-Wallops facility. Electrostatic analyzer data provided a record of the rocket body potential, and indications of ion production, or energy-angle scattering within the plasma sheath. Plasma wave information was extracted from floating probe data and skin current probe …
-
Investigation of the threshold behavior of the cross section for collisional dissociation of diatomic molecules
… were taken with a 160° spherical sector electrostatic analyzer in coincidence with the neutral fragments detected in a charge state analyzer. The spectra were transformed from the laboratory frame to the projectile rest frame. The resulting yields were studied as a function of energy near …
-
ROCKET-BORNE LOW ENERGY ION MEASUREMENTS IN SPACE
A capped hemisphere electrostatic analyzer has been developed for the purpose of performing detailed studies of charged particle distributions in space from sounding rocket platforms. This instrument employs micro channel plate detectors in conjunction with a linear resistive anode to carry out …
-
Plasma flow field measurements downstream of a hollow cathode
… space applications, hollow cathodes are used in electrostatic propulsion devices, especially in ion thrusters and Hall thrusters, to provide electrons to sustain the plasma discharge and neutralize the ion beam. This research is considered important based upon previous thruster life tests that …
-
Partial differential cross-sections for electron production by 20 to 120 keV proton impact on argon
… a reasonable energy resolution, a new type of electrostatic analyzer was developed and built which has a large ($\sim$1.45$\pi$ steradian) solid angle acceptance. This analyzer, which is similar to apparatus used in low energy electron diffraction (LEED) experiments, has a low-pass filter …
-
Fine structure of auroral particle acceleration
A mass-analyzing capped hemispherical electrostatic analyzer has been developed for the purpose of resolving the mass, energy, and pitch angle distributions of auroral ions. The instrument, the B-field Hemispherical Electrostatic Energy and Pitch Angle Spectrometer (BEEPS), is an extension of the …
-
Doubly differential cross sections for ejection of electrons from atomic and molecular hydrogen by 30--120 keV helium(+) ion impact
… eV. Ejected electrons were energy analyzed by an electrostatic analyzer with 5% resolution and were detected by a channel electron multiplier. A Slevin-type RF hydrogen atom source was used to generate a mixed target of atomic and molecular hydrogen. The dissociation fraction of the target was …
-
Electron emission in collisions of 0.5 MeV/u C²⁺₂ai
… apparatus consists of a 30° parallel plate electrostatic analyzer with a large position sensitive detector (PSD), a recoil ion time of flight (RITOF) spectrometer, and a charge state analyzer.</p> <p>This work focuses on measuring the energy and angular distribution of electrons ejected …
-
Optical and ion energy spectroscopy of laser-produced plasmas
… x 10¹⁶ Wm⁻² ) in vacuum. A 45° parallel plate electrostatic analyzer was built to record the energy spectra of the streaming ions. Space charge effects within the analyzer are examined quantitatively. Ion velocity spectra, deduced from the energy spectra and covering the range 1-5 x 10⁵ ms⁻¹ , …
-
On the detection of two electrons in low-lying continuum states of a single projectile ion resulting from the collision of a 10.7 MeV AG4+ ion with an AR gas target
… feasibility of using a large 30° parallel plate electrostatic analyzer to detect two electrons in low lying continuum states of a projectile ion. The two electrons are excited just above the double ionization threshold of a Ag<sup>q+</sup> projectile ion in a collision of a 0.1 MeV/u …
-
Carbon K-Shell X-Ray and Auger-Electron Cross Sections and Fluorescence Yields for Selected Molecular Gases by 0.6 To 2 .0 MeV Proton Impact
… constant transmission energy Π/4 parallel pi ate electrostatic analyzer. Absolute carbon K-shell x-ray cross sections for CH₄ are compared to the known results of Khan et al. (1965). Auger-electron cross sections for proton impact on CH₄ are compared to the known experimental values of RΦdbro et …
-
Performance and plume characterization of a laboratory krypton Hall thruster
… Thrust measurement, along with data from an Electrostatic Analyzer (ESA), ExB probe, and Faraday probe were collected to determine the performance characteristics of the thruster as well as the characteristics of the ion beam in each of the three cases outlined above. Additionally, a …
-
Electron emission in grazing ion-surface collisions
… using a 160° spherical sector electron energy analyzer employing a position sensitive detector. Such arrangement permitted simultaneous measurement of the energy and angular distributions of emitted electrons. An electrostatic analyzer in combination with a movable electron multiplier detector …
-
Photoelectron spectroscopic studies of some polyatomic molecules
… the molecule. Retarding fields, a 180° magnetic analyzer, a 127° electrostatic analyzer and a 180° hemi-spherical analyzer have been used to measure the electron energies. In this work only the first method was used. A spherical photoelectron spectrometer was used to make the measurements. This …
-
The Development of a Medium Energy Ion Reflection Spectrometer and Some Problems Associated with its Application to Materials Analysis
… the spectrometer. They include a high resolution electrostatic analyzer and a premium solid state detector cooled to provide an excellent resolution figure. Control of the spectrometer is via a small minicomputer programmed with machine language in a real-time operating environment. Both energy …
-
A high-speed mass spectrometer for characterizing flash desorbed species in pulsed power applications
… This probe is known as the Energy and Velocity Analyzer for Distributions of Electric Rockets (EVADER) probe, which combines an electrostatic analyzer and a Wien velocity filter. Within this study, two different plasma sources were used separately to simulate the plasma generated in the Z …