Commissioning and out-of-field dose characterisation of the Elekta Unity MRL
Marcus Powers commissioned the Southern Hemisphere's first clinical MRI-guided Linear Accelerator and assessed radiation doses during treatments with the machine. He found it was suitable for the provision of cancer therapy and revealed potential unintended radiation deposition to distal patient …
-
Design and Validation of a Prototype Collimation System with Reduced Applicator Weights for Elekta Electron Therapy Beams
… was to design an electron collimation system for Elekta Infinity accelerators with significantly reduced applicator weights, while maintaining acceptable in-field beam flatness and out-of-field leakage dose. The design was restricted to 6-20 MeV beams for 6x6 to 25x25 cm2 applicators at 100 cm SSD …
-
Volumetric Modulated Arc Therapy Evaluation With The Radiological Physics Center Head and Neck Phantom
… of this project was to compare two VMAT systems, Elekta VMAT and Varian RapidArc, to the current standard of care, IMRT, in terms of both treatment plan quality and dosimetric delivery accuracy using the Radiological Physics Center (RPC) head and neck (H&N) phantom. Clinically relevant treatment …
-
Development of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit to ol For Clinical Trials
… source models representing the output of Elekta 6MV and 10MV and Varian TrueBeam Flattening Filter Free (FFF) 6MV and FFF 10MV therapeutic x-ray beams were developed. The Monte Carlo technique, using the Dose Planning Method (DPM) algorithm, was used in radiation dose calculations. During …
-
The Clinical Effect of Changing from a Dose to Water to a Dose to Medium-Based Methodology to Calculate Monitor Units for Electron Beams
… North Coast Cancer Institute (MNCCI) implemented Elekta’s Monaco® electron Monte Carlo (eMC) dose calculation algorithm for electron beams. The new algorithm resulted in a change in clinical practice whereby monitor units (MU) delivered to patients would be calculated in terms of dose to medium …
-
Investigation into the use of Four Dimensional Cone Beam Computed Tomography for Internal Target Volume definition in Lung Stereotactic Ablative Body Radiation
… 4DCBCT, using two different linear accelerators: Elekta® Linear Accelerator (Elekta AB, Stockholm, Sweden) and a Varian® Linear Accelerator (Varian Medical Systems, Palo Alto, CA, USA). A motion phantom was employed to simulate patient breathing and tumour movement. The high-energy radiation used …
-
Polymer Gel Dosimetry in Magnetic Resonance-Image Guided Radiation Therapy
… by MGS Research were characterized with the Elekta Versa HD™ linear accelerator and compared to the characterizations performed with a GMW electromagnet installed in the linear accelerator vault and with the Elekta MR-Linac, a 7 MV linear accelerator integrated with a 1.5 T MR scanner. …
-
Detectors in Medical Physics Measuring Dose by Detectors
… at dmax for two energies 6 MV and 10 MV on the Elekta machine. This was done by using only two points and comparing the results with percentage depth dose (PDD) for the depth dose curve for both energies. In addition the doses were obtained by using three method of detectors suck as the ion …
-
Experimental Verification of 4D Monte Carlo Simulations of Dose Delivery to Moving and Deforming Anatomies
… Dose deliveries were performed on an Elekta Infinity linac with Agility MLC for static and volumetric modulated arc therapy treatments on the stationary and breathing states of the phantoms. The dose was measured with film (point dose and dose profile) and the RADPOS 4D dosimetry …
-
On the use of an endorectal balloon in ultrahypofractionated MR-guided radiotherapy of prostate cancer
… mit einem ERB an einem Unity MR-LINAC (Elekta) ultrahypofraktioniert bestrahlt wurden. Die zweite Kohorte umfasste zehn Patienten, die im gleichen Zeitraum ohne ERB an der Universitätsklinik für Strahlentherapie Tübingen ebenfalls an einem Unity MR-LINAC (Elekta) mittels …
-
Neutron exposure from electrom linear accelerators and a proton accelerator : measurements and simulations
… found that ambient neutron dose equivalents from Elekta accelerator were significant lower than from Varian accelerator, especially for 18MV beams. Neutron dose equivalent per therapeutic dose (H/D) around the MEVION S250 Proton Therapy System were evaluated using measurements and MCNPX …
-
Dosimetric effects of removing the flattening filter in radiotherapy treatment units
… and Monte Carlo simulations for a modified Elekta Precise linear accelerator, operating with and without a flattening filter, were performed and the differences were evaluated. For an Elekta Precise linac, it was found that by removing the flattening filter the dose could be delivered …
-
Monte Carlo techniques for electron radiotherapy
… different energies and field sizes provided by ELEKTA SL18 Linac available at the University Hospital of Larisa. The measurements were performed for the central axis percent depth dose (pdd), and the off-axis dose profiles at the depth of maximum dose (Dmax). Choosing, installing and using a …
-
Development of an Independent Monte Carlo Dose Calculation Tool for Validation of the Monaco Electron Treatment Planning System
… and measured percent depth dose (PDD) data from Elekta Synergy and Agility therapy accelerators for multiple fields and source to surface distances (SSD). Spectra were initially determined without applicators present and thereby removed a significant variable in modelling. The accelerator head …
-
A phantom based evaluation on the effects of patient breathing motion on Stereotactic Body Radiotherapy treatment volumes
… data. Two treatment planning systems (Monaco, (Elekta) and Eclipse (Varian)) were used to determine the dosimetric characteristics of the materials. This was compared to actual dose as delivered by a linear accelerator (Elekta Synergy). Results: Paths were calculated from the breathing cycles …
-
Μελέτη γωνιακής εξάρτησης δοσιμέτρων οπτικής φωταύγειας σε 1.5Τ μαγνητικό πεδίο
Έπειτα από την κλινική εισαγωγή του Elekta Unity MR-linac, υπάρχει επείγουσα ανάγκη για ανάπτυξη πρωτοκόλλων και εργαλείων δοσιμετρίας. Η παρουσία ισχυρού μαγνητικού πεδίου, τροποποιεί τις τροχιές των φορτισμένων σωματιδίων και κατ’ επέκταση την απόκριση των δοσιμέτρων. Ωστόσο, οι περισσότερες …
-
Image quality and dose of an accelerator-integrated kV CBCT systems
… radiotherapy: Varian On-Board Imager (OBI) and Elekta X-ray Volumetric Imager (XVI). Several imaging quality tests were performed using current clinical imaging protocols provided with both systems and various types of image quality phantoms. CBCT imaging dose of each system was also estimated …
-
Optimization Models and Techniques for Radiation Treatment Planning Applied to Leksell Gamma Knife(R) Perfexion(TM)
… models which we developed for PerfexionTM unit (Elekta, Stockholm, Sweden), in essence, have come to the assistance of oncologists in automatically locating isocentres and de ning sector durations. Sector duration optimization (SDO) and sector duration and isocentre location optimization (SDIO) …
-
Διερεύνηση ποσοτικών δεικτών αξιολόγησης της κατανομής δόσης καρκίνου προστάτη με εξωτερική ακτινοθεραπεία
… εφαρμόστηκαν σε γραμμικό επιταχυντή infinity της Elekta. Σε κάθε πλάνο υπολογίστηκε από το ίδιο το σύστημα ο δείκτης συμμόρφωσης της δόσης CI και επίσης υπολογίστηκαν οι δείκτες CIrp, CIrtog, CIdexp, CIlomax και CIsalt, δημιουργώντας νέες δομές μέσω του treatment planning system. Στατιστική …