Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 172 for “"Eluent"”.

  1. Eluent and ligand effects in cation chromatography

    … resins. Effects of complexing agents in the eluent are also examined for their effects on selectivity. Elution behavior with both complexing and non-complexing eluents are found to be predicted readily by use of the mass-action equilibrium expression for ion-exchange systems;The addition of …

    iastate Repository record for Eluent and ligand effects in cation chromatography (opens in a new tab)

  2. Electrodialytic membrane eluent generators and suppressors for ion chromatography

    … "swamped out" by that of the much more abundant eluent electrolyte. This situation was likened to looking for a needle in a haystack. The problem was solved by using a combination of resins which stripped out or neutralized the ions of the eluent electrolyte leaving only the species of interest …

    ttu Repository record for Electrodialytic membrane eluent generators and suppressors for ion chromatography (opens in a new tab)

  3. Development of HPLC-FID Coupling Using Water as the Eluent

    The characterization of all components of pharmaceutical preparations, especially in the analysis of impurities present at levels higher than 0.05% of the main component, is a challenge in the pharmaceutical industry because no single detector can detect all impurities present. All commercial …

    waterloo Repository record for Development of HPLC-FID Coupling Using Water as the Eluent (opens in a new tab)

  4. Indirect Photometric Chromatography of Inorganic and Organic Anions Using Benzoate as an Eluent

    … organic acids. The application of the benzoate eluent with UV detection method to the determination of anions was demonstrated via the analysis of chloride, EDTA and sorbate in a commercial saline solution. The limits of detection for injected chloride and EDTA were 1.5 ppm, while sorbate was …

    eiu Repository record for Indirect Photometric Chromatography of Inorganic and Organic Anions Using Benzoate as an Eluent (opens in a new tab)

  5. Selectivity Optimization in Tandem Column Liquid Chromatography Using the Eluent Composition as the Tuning Variable

    … variable (e.g. temperature, flow rate, eluent composition) which has different values for the two columns to continuously “tune” the selectivity. We call this family of techniques XT2C, meaning that the variable X (temperature, etc.) is used to continuously tune the combined selectivity …

    umn Repository record for Selectivity Optimization in Tandem Column Liquid Chromatography Using the Eluent Composition as the Tuning Variable (opens in a new tab)

  6. HPLC of Homologous Series of Simple Organic Anions and Cations on an Anion Exchange Column

    … factor of organic anions vs. reciprocal of eluent ion concentration showed good linearity. From the slope and y-intercept data the retention mechanism of organic ion was interpreted as ion exchange and reversed phase interactions. The effects of temperature, acetonitrile concentration of the …

    marquette Repository record for HPLC of Homologous Series of Simple Organic Anions and Cations on an Anion Exchange Column (opens in a new tab)

  7. HPLC of homologous series of simple organic anions and cations on an anion exchange column

    … factor of organic anions vs. reciprocal of eluent ion concentration showed good linearity. From the slope and y-intercept data the retention mechanism of organic ion was interpreted as ion exchange and reversed phase interactions. The effects of temperature, acetonitrile concentration of the …

    marquette Repository record for HPLC of homologous series of simple organic anions and cations on an anion exchange column (opens in a new tab)

  8. Development of complexation ion chromatography for the determination of metal ions

    … based upon the use of a colourforming complexing eluent and direct visible detection of the eluting Pb(II) complex. Using the combination of a strong cation exchange column and an eluent consisting of 20 mM sodium acetate-acetic acid buffer and 0.2 mM xylenol orange (XO) (~pH = 4.2), Pb(II) was …

    dcu Download PDF for Development of complexation ion chromatography for the determination of metal ions (opens in a new tab)

  9. Determination of transition metals by high performance liquid chromatography.

    … and solved were: metalcontamination of the eluent,finding a suitable pump for the system, minimising the noise and reducing the elution times. Detection of the separated metal ions was enabled by post-column derivatisation prior to introduction to thespectrophotometric detector. This …

    sheffield-hallam Download PDF for Determination of transition metals by high performance liquid chromatography. (opens in a new tab)

  10. Resorcinarene-Based Cavitands: From Structural Design and Synthesis to Separations Applications

    … showed selectivity for Cu2+ when no chelating eluent was used in the eluent, a selectivity which was not observed with a commercial column containing standard cation-exchangers. Six metal ions (Cu2+, Mn2+, Co2+, Ni2+, Cd2+, and Zn2+) were separated on the AUA column within a reasonable time …

    byu Repository record for Resorcinarene-Based Cavitands: From Structural Design and Synthesis to Separations Applications (opens in a new tab) Download PDF for Resorcinarene-Based Cavitands: From Structural Design and Synthesis to Separations Applications (opens in a new tab)

  11. Investigation of electrostatic ion chromatography for the separation of inorganic ions

    … to the separation of ions using pure water as an eluent, without the addition of any inorganic buffers or organic modifiers. The nature of the separation, le cationic or anionic, is dependent upon the nature of the zwittenomc stationary phase. In the work presented here, the zwittenomc surfactant …

    dcu Download PDF for Investigation of electrostatic ion chromatography for the separation of inorganic ions (opens in a new tab)

  12. Chemically modified polymeric resins for separation of cations, organic acids, and small polar molecules by high performance liquid chromatography

    … of excellent separations are reported using eluents containing ethylenediammonium cations plus a weak complexing agent. The effect of pH on retention times of metal ions is reported;Separation of carboxylic acids and other polar compounds by ion-exclusion chromatography is usually performed …

    iastate Repository record for Chemically modified polymeric resins for separation of cations, organic acids, and small polar molecules by high performance liquid chromatography (opens in a new tab)

  13. In-line combination of LC with MS,, NMR, UV and IR in drug analysis.

    … a working combination was achieved choice of eluent remained difficult, principally because of eluent signals in the NMR recordings. Deuterated eluents were expensive and still contained residual proton signals. In chapter 2 the feasibility of LC-NMR-MS is demonstrated, while some limits on …

    sheffield-hallam Download PDF for In-line combination of LC with MS,, NMR, UV and IR in drug analysis. (opens in a new tab)

  14. Multicomponent separations using a continuous annular chromatograph

    … at a stationary point at the top of the bed and eluent everywhere else around the annulus, elution chromatography occurs. The rotation rate of the sorbent bed causes the separated components to appear as helical bands, each of which has a characteristic, stationary exit point; hence, the …

    utk-theses Repository record for Multicomponent separations using a continuous annular chromatograph (opens in a new tab)

  15. Investigating mineral dissolution kinetics by Flow-Through Time-Resolved Analysis (FT-TRA)

    … of a gradient pump, which continuously passes eluent of fixed or varying composition through a small flow-through reactor containing a small amount of solid sample. The effluent composition is then analyzed online using an inductively coupled plasma mass spectrometer in time-resolved mode, or …

    ubc Repository record for Investigating mineral dissolution kinetics by Flow-Through Time-Resolved Analysis (FT-TRA) (opens in a new tab) Download PDF for Investigating mineral dissolution kinetics by Flow-Through Time-Resolved Analysis (FT-TRA) (opens in a new tab)

  16. Ion chromatography with low-capacity resins and low-conductivity eluents

    … an aromatic organic acid salt is needed as the eluent. The eluent conductance is sufficiently low so that a suppressor column is not needed and the separated anions can be detected with a simple conductance detector. Numerous examples of actual separations are shown. In some cases, …

    iastate Repository record for Ion chromatography with low-capacity resins and low-conductivity eluents (opens in a new tab)

Page 1 of 9