Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 3 of 3 for “"End One Flange Loading"”.

  1. Direct Strength Method for Web Crippling of Cold-formed Steel C and Z Sections Subjected to Interior One Flange Loading and End One Flange Loading

    The main objective of this research is to extend the “Direct strength method” for determining the web crippling strength of cold-formed steel C and Z sections subjected to End one flange loading and Interior one flange loading conditions. Direct strength method is applied for designing the columns …

    unt Repository record for Direct Strength Method for Web Crippling of Cold-formed Steel C and Z Sections Subjected to Interior One Flange Loading and End One Flange Loading (opens in a new tab)

  2. Web-Crippling Strength of Multi-Web Cold-Formed Steel Deck Sections Subjected to End One Flange (EOF) Loading

    … for different load cases and different end conditions, in the End One Flange (EOF) loading case, coefficients for the unfastened configuration were used as a conservative solution for the fastened case because there was no directly applicable test data available in the literature. This …

    vt Repository record for Web-Crippling Strength of Multi-Web Cold-Formed Steel Deck Sections Subjected to End One Flange (EOF) Loading (opens in a new tab)

  3. Strength of Cold-Formed Steel Jamb Stud-To-Track Connections

    … and must be checked for web crippling at the end reactions. While a design expression currently exists for the single stud-to-track connection, there is no similar design expression for multiple jamb stud members. An experimental investigation was carried out, consisting of 94 jamb stud …

    waterloo Repository record for Strength of Cold-Formed Steel Jamb Stud-To-Track Connections (opens in a new tab)