Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 20 for “"Endodontic instruments"”

  1. The structural and physical properties of endodontic instruments

    Endodontic instruments are manufactured by many companies throughout the world. Since no evidence exists in the literature concerning the variable quality of the instruments on the market, the following investigation was undertaken with the objective to compare a sample of instruments from some of …

    bu Repository record for The structural and physical properties of endodontic instruments (opens in a new tab)

  2. An investigation of phase transformation mechanisms for nickel-titanium rotary endodontic instruments

    Nickel-titanium rotary instruments based upon the intermetallic compound NiTi have gained considerable popularity among endodontists because the very low elastic modulus of NiTi enables these instruments to readily negotiate curved root canals during endodontic therapy with a slow-speed handpiece. …

    ohiolink Repository record for An investigation of phase transformation mechanisms for nickel-titanium rotary endodontic instruments (opens in a new tab)

  3. Characterization of New Rotary Endodontic Instruments Fabricated from Special Thermomechanically Processed NiTi Wire

    Although NiTi rotary instruments are very popular for endodontic treatment, instrument separation is still a challenge in clinic. A new NiTi rotary instrument has recently been marketed that is machined from M-Wire that has been subjected to a proprietary novel thermomechanical processing …

    ohiolink Repository record for Characterization of New Rotary Endodontic Instruments Fabricated from Special Thermomechanically Processed NiTi Wire (opens in a new tab)

  4. Comparative surface roughness analysis of rotary endodontic instruments using non-contact digital microscopy

    The full abstract for this thesis is available in the body of the thesis, and will be available when the embargo expires.

    ubc Repository record for Comparative surface roughness analysis of rotary endodontic instruments using non-contact digital microscopy (opens in a new tab)

  5. Thermally treated niti endodontic instruments and its application in root canal cleaning and shaping /

    … to clarify how efficient thermally treated NiTi instruments are in root canal cleaning and shaping and if they are superior to other File Systems or not. What is the status of the development of thermally treated instruments? Are there any new thermal treatment processes, and how effective are …

    vilnius Repository record for Thermally treated niti endodontic instruments and its application in root canal cleaning and shaping / (opens in a new tab)

  6. Differential Scanning Calorimetric (DSC) Study of New and Sterilized Nickel-Titanium Rotary Endodontic Instruments

    … (NiTi) files have become popular in endodontic procedures compared to traditional stainless steel hand files owing to their increased flexibility which is especially advantageous in curved canals. Due to the associated costs, endodontic instruments are frequently re-used, which …

    marquette Repository record for Differential Scanning Calorimetric (DSC) Study of New and Sterilized Nickel-Titanium Rotary Endodontic Instruments (opens in a new tab)

  7. Effect of previous angular deformation on flexural fatigue resistance of controlled memory nickel-titanium endodontic instruments

    … angle on fatigue resistance of Typhoon (TYP) CM instruments. Methodology: TYP NiTi 25/.04, TYP NiTi 40/.04, TYP CM 25/.04 and TYP CM 40/.04 were rotated until fracture to obtain the mean angular deflection according to the +-ISO 3630-1 standard. Files were pre-torqued to 25, 50, and 75% of their …

    ubc Repository record for Effect of previous angular deformation on flexural fatigue resistance of controlled memory nickel-titanium endodontic instruments (opens in a new tab)

  8. Low-cycle cyclic fatigue properties of novel nickel-titanium rotary endodontic instruments in the single- and double-curvatures.

    Introduction: This in vitro study aimed to evaluate and compare the fatigue resistance of ProFile Vortex® (VX) and Vortex Blue® (VB) files in two different artificial double curvature canals (DC1 and DC2) and in an artificial single curvature canal (SC). The bending moment of VX and VB was …

    ubc Repository record for Low-cycle cyclic fatigue properties of novel nickel-titanium rotary endodontic instruments in the single- and double-curvatures. (opens in a new tab)

  9. Influencia de los factores relacionados con la fatiga cíclica de las limas endodónticas de NiTi

    [EN] The endodontic rotary and reciprocating files of NiTi has reported to exhibit unexpected fractures inside the root canal system during the root canal treatment; which can affect the prognosis of the endodontic therapy. Therefore, it is important to assess the variables related to this …

    salamanca Repository record for Influencia de los factores relacionados con la fatiga cíclica de las limas endodónticas de NiTi (opens in a new tab)

  10. Torsional Testing of Race, K3 and Profile Nickel Titanium Endodontic Files

    Rotary endodontic instruments have different cross sectional designs that may effect their resistance to torsional stress. The purpose of this study is to evaluate the static torsional properties of two nickel titanium files that have recently been introduced for use in endodontics and compare them …

    vcu Repository record for Torsional Testing of Race, K3 and Profile Nickel Titanium Endodontic Files (opens in a new tab)

  11. Comparison of Three Different Nickel-Titanium Endodontic Rotary Systems in Shaping Simulated S-Shaped Canals

    … resistance to fracture are ideal properties that endodontic instruments should have. The aim of the study was to compare the shaping ability of three different nickel-titanium rotary instruments in simulated S-shape root canals by measuring transportation and canal volume change CVC. Materials and …

    marquette Repository record for Comparison of Three Different Nickel-Titanium Endodontic Rotary Systems in Shaping Simulated S-Shaped Canals (opens in a new tab)

  12. Avaliação das propriedades físico-químicas de instrumentos reciprocantes de níquel-titânio tratados termicamente

    Reciprocating nickel-titanium endodontic instruments have been developed to obtain a faster and safer preparation, however, these instruments have the disadvantage of fracturing during use. Facing this disadvantage, manufacturers have developed changes in instrument design and alloy finishes, as …

    brazil-ufrn Repository record for Avaliação das propriedades físico-químicas de instrumentos reciprocantes de níquel-titânio tratados termicamente (opens in a new tab)

  13. The effect of cyclic fatigue on the hardness of new NiTi endodontic files : a nanoindentation study

    … on the hardness of both PTG and PTU NiTi rotary endodontic instruments. Methodology: PTU and PTG instruments were subjected to rotational bending at a curvature of 40° and a radius of 6mm. The number of cycles to fracture (NCF) was recorded. According to the ISO 3630-1 specification, 45° bending …

    ubc Repository record for The effect of cyclic fatigue on the hardness of new NiTi endodontic files : a nanoindentation study (opens in a new tab)

  14. Quantitative assessment of covariants of root canal treatment efficacy in human teeth

    … researchers and dental instrument manufacturers. Endodontics has been one of the most developing fields of dental science in recent years. There have been new instruments, materials, and methods introduced, which have been very rapidly adopted since most facilitate the root canal treatment …

    jamescook Repository record for Quantitative assessment of covariants of root canal treatment efficacy in human teeth (opens in a new tab)

  15. Vorgaben zur manuellen Aufbereitung von Wurzelkanalinstrumenten

    Wurzelkanalinstrumente kommen bei ihrem Einsatz mit Körperflüssigkeiten und -geweben in Berührung und sind daher nach jedem Gebrauch als kontaminiert zu betrachten und vor erneutem Gebrauch aufzubereiten, um Kreuzinfektionen bei Patienten auszuschließen. Für die Durchführung einer erfolgreichen …

    fu-berlin Repository record for Vorgaben zur manuellen Aufbereitung von Wurzelkanalinstrumenten (opens in a new tab)

  16. Μελέτη του μηχανισμού θραύσης μηχανοκίνητων μικροεργαλείων ενδοδοντίας νικελίου-τιτανίου σε ευθείς και κεκαμμένους ριζικούς σωλήνες

    … on the failure mechanism of rotary Ni-Ti endodontic instruments of the ProFile system (Dentsply Maillefer, Ballaigues, Switzerland) under standardized simulated clinical conditions for a known number of consecutive uses. Three hundred mesial root canals from freshly extracted human …

    greece Repository record for Μελέτη του μηχανισμού θραύσης μηχανοκίνητων μικροεργαλείων ενδοδοντίας νικελίου-τιτανίου σε ευθείς και κεκαμμένους ριζικούς σωλήνες (opens in a new tab)

  17. Détermination rapide de la durée de vie en fatigue oligocyclique de structures au comportement inélastique confiné : application aux instruments endodontiques en alliage à mémoire de forme Nickel-Titane

    … employés dans le cadre de l’élaboration d'instruments endodontiques. Leurs grandes souplesses permettent d’épouser la forme courbée des canaux dentaires. Cependant, des ruptures en service par fatigue sont parfois observées. La prise en compte du dimensionnement en fatigue des instruments …

    star-france Repository record for Détermination rapide de la durée de vie en fatigue oligocyclique de structures au comportement inélastique confiné : application aux instruments endodontiques en alliage à mémoire de forme Nickel-Titane (opens in a new tab)

  18. SODIUM HYPOCHLORITE'S EFFECT ON NICKEL-TITANIUM ROTARY INSTRUMENTS AND ITS EFFECT ON RESISTANCE TO FRACTURE

    The purpose of this study was to examine the effect of partial and total immersion in sodium hypochlorite on nickel-titanium rotary files and to determine whether resistance to fracture was influenced by the immersion time. One hundred K3™ and 100 ProFile® rotary files were either partially or …

    vcu Repository record for SODIUM HYPOCHLORITE'S EFFECT ON NICKEL-TITANIUM ROTARY INSTRUMENTS AND ITS EFFECT ON RESISTANCE TO FRACTURE (opens in a new tab)

  19. Flexible TiO₂ coating on superelastic NiTi alloys for bioapplications

    … sol-gel a été utilisée pour revêtir des instruments endodontiques de RaCe. Ce deuxième système a été testé à la fois en fatigue pour estimer sa durée de vie, et à la résistance à la corrosion en NaClO, et à des températures correspondant aux transformations de phase. Les résultats ont …

    star-france Repository record for Flexible TiO₂ coating on superelastic NiTi alloys for bioapplications (opens in a new tab) Restricted access

  20. Influence des traitements thermiques sur les performances et la tenue en service des instruments endodontiques

    … but d'améliorer la résistance à la rupture des instruments endodontique en NiTi, les recherches s'orientent de plus en plus vers les procédés de post-fabrication tels que les traitements de surface et l'application des traitements thermiques. Cependant, peu derecherches se sont tournées vers une …

    star-france Repository record for Influence des traitements thermiques sur les performances et la tenue en service des instruments endodontiques (opens in a new tab)