The structural and physical properties of endodontic instruments
Endodontic instruments are manufactured by many companies throughout the world. Since no evidence exists in the literature concerning the variable quality of the instruments on the market, the following investigation was undertaken with the objective to compare a sample of instruments from some of …
-
An investigation of phase transformation mechanisms for nickel-titanium rotary endodontic instruments
Nickel-titanium rotary instruments based upon the intermetallic compound NiTi have gained considerable popularity among endodontists because the very low elastic modulus of NiTi enables these instruments to readily negotiate curved root canals during endodontic therapy with a slow-speed handpiece. …
-
Characterization of New Rotary Endodontic Instruments Fabricated from Special Thermomechanically Processed NiTi Wire
Although NiTi rotary instruments are very popular for endodontic treatment, instrument separation is still a challenge in clinic. A new NiTi rotary instrument has recently been marketed that is machined from M-Wire that has been subjected to a proprietary novel thermomechanical processing …
-
Comparative surface roughness analysis of rotary endodontic instruments using non-contact digital microscopy
The full abstract for this thesis is available in the body of the thesis, and will be available when the embargo expires.
-
Thermally treated niti endodontic instruments and its application in root canal cleaning and shaping /
… to clarify how efficient thermally treated NiTi instruments are in root canal cleaning and shaping and if they are superior to other File Systems or not. What is the status of the development of thermally treated instruments? Are there any new thermal treatment processes, and how effective are …
-
Differential Scanning Calorimetric (DSC) Study of New and Sterilized Nickel-Titanium Rotary Endodontic Instruments
… (NiTi) files have become popular in endodontic procedures compared to traditional stainless steel hand files owing to their increased flexibility which is especially advantageous in curved canals. Due to the associated costs, endodontic instruments are frequently re-used, which …
-
Effect of previous angular deformation on flexural fatigue resistance of controlled memory nickel-titanium endodontic instruments
… angle on fatigue resistance of Typhoon (TYP) CM instruments. Methodology: TYP NiTi 25/.04, TYP NiTi 40/.04, TYP CM 25/.04 and TYP CM 40/.04 were rotated until fracture to obtain the mean angular deflection according to the +-ISO 3630-1 standard. Files were pre-torqued to 25, 50, and 75% of their …
-
Low-cycle cyclic fatigue properties of novel nickel-titanium rotary endodontic instruments in the single- and double-curvatures.
Introduction: This in vitro study aimed to evaluate and compare the fatigue resistance of ProFile Vortex® (VX) and Vortex Blue® (VB) files in two different artificial double curvature canals (DC1 and DC2) and in an artificial single curvature canal (SC). The bending moment of VX and VB was …
-
Influencia de los factores relacionados con la fatiga cíclica de las limas endodónticas de NiTi
[EN] The endodontic rotary and reciprocating files of NiTi has reported to exhibit unexpected fractures inside the root canal system during the root canal treatment; which can affect the prognosis of the endodontic therapy. Therefore, it is important to assess the variables related to this …
-
Torsional Testing of Race, K3 and Profile Nickel Titanium Endodontic Files
Rotary endodontic instruments have different cross sectional designs that may effect their resistance to torsional stress. The purpose of this study is to evaluate the static torsional properties of two nickel titanium files that have recently been introduced for use in endodontics and compare them …
-
Comparison of Three Different Nickel-Titanium Endodontic Rotary Systems in Shaping Simulated S-Shaped Canals
… resistance to fracture are ideal properties that endodontic instruments should have. The aim of the study was to compare the shaping ability of three different nickel-titanium rotary instruments in simulated S-shape root canals by measuring transportation and canal volume change CVC. Materials and …
-
Avaliação das propriedades físico-químicas de instrumentos reciprocantes de níquel-titânio tratados termicamente
Reciprocating nickel-titanium endodontic instruments have been developed to obtain a faster and safer preparation, however, these instruments have the disadvantage of fracturing during use. Facing this disadvantage, manufacturers have developed changes in instrument design and alloy finishes, as …
-
The effect of cyclic fatigue on the hardness of new NiTi endodontic files : a nanoindentation study
… on the hardness of both PTG and PTU NiTi rotary endodontic instruments. Methodology: PTU and PTG instruments were subjected to rotational bending at a curvature of 40° and a radius of 6mm. The number of cycles to fracture (NCF) was recorded. According to the ISO 3630-1 specification, 45° bending …
-
Quantitative assessment of covariants of root canal treatment efficacy in human teeth
… researchers and dental instrument manufacturers. Endodontics has been one of the most developing fields of dental science in recent years. There have been new instruments, materials, and methods introduced, which have been very rapidly adopted since most facilitate the root canal treatment …
-
Vorgaben zur manuellen Aufbereitung von Wurzelkanalinstrumenten
Wurzelkanalinstrumente kommen bei ihrem Einsatz mit Körperflüssigkeiten und -geweben in Berührung und sind daher nach jedem Gebrauch als kontaminiert zu betrachten und vor erneutem Gebrauch aufzubereiten, um Kreuzinfektionen bei Patienten auszuschließen. Für die Durchführung einer erfolgreichen …
-
Μελέτη του μηχανισμού θραύσης μηχανοκίνητων μικροεργαλείων ενδοδοντίας νικελίου-τιτανίου σε ευθείς και κεκαμμένους ριζικούς σωλήνες
… on the failure mechanism of rotary Ni-Ti endodontic instruments of the ProFile system (Dentsply Maillefer, Ballaigues, Switzerland) under standardized simulated clinical conditions for a known number of consecutive uses. Three hundred mesial root canals from freshly extracted human …
-
Détermination rapide de la durée de vie en fatigue oligocyclique de structures au comportement inélastique confiné : application aux instruments endodontiques en alliage à mémoire de forme Nickel-Titane
… employés dans le cadre de l’élaboration d'instruments endodontiques. Leurs grandes souplesses permettent d’épouser la forme courbée des canaux dentaires. Cependant, des ruptures en service par fatigue sont parfois observées. La prise en compte du dimensionnement en fatigue des instruments …
-
SODIUM HYPOCHLORITE'S EFFECT ON NICKEL-TITANIUM ROTARY INSTRUMENTS AND ITS EFFECT ON RESISTANCE TO FRACTURE
The purpose of this study was to examine the effect of partial and total immersion in sodium hypochlorite on nickel-titanium rotary files and to determine whether resistance to fracture was influenced by the immersion time. One hundred K3 and 100 ProFile® rotary files were either partially or …
-
Flexible TiO₂ coating on superelastic NiTi alloys for bioapplications
… sol-gel a été utilisée pour revêtir des instruments endodontiques de RaCe. Ce deuxième système a été testé à la fois en fatigue pour estimer sa durée de vie, et à la résistance à la corrosion en NaClO, et à des températures correspondant aux transformations de phase. Les résultats ont …
-
Influence des traitements thermiques sur les performances et la tenue en service des instruments endodontiques
… but d'améliorer la résistance à la rupture des instruments endodontique en NiTi, les recherches s'orientent de plus en plus vers les procédés de post-fabrication tels que les traitements de surface et l'application des traitements thermiques. Cependant, peu derecherches se sont tournées vers une …