Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 16 of 16 for “"Endografts"”.
-
Endografts, Pressure, and the Abdominal Aortic Aneurysm
… a means to investigate the biomechanics of endografts treating AAA through analysis of the endografts, the AAA, and the combination of them. Axisymmetric models of endograft-treated AAA showed that peak von Mises stress within the wall varied between 533 kPa and 1200 kPa when different …
-
Graphene: the future of endografts and stents?
Το γραφένιο, ένα δισδιάστατο νανο-υλικό που αποτελείται από άτομα άνθρακα με sp2 δεσμούς, έχει μια πληθώρα εξαιρετικών ιδιοτήτων. Το γραφένειο και τα παράγωγα του έχουν επιδείξει σημαντικές δυνατότητες σε πολλούς τομείς, συμπεριλαμβανομένης της αγγειοπλαστικής των στεφανιαίων αγγείων. Τα ήδη …
-
The Effect of Endografts on the Propagation of Aortic Dissection: A Fluid-Structure Interaction (FSI) Finite-Element Model of Flow through the Descending Thoracic Aorta
Tears in the lining of the aorta are termed aortic dissections. Aortic dissections affect 12,000 new patients per year in the US and are associated with significant morbidity and mortality. The primary management method is an invasive and difficult surgery to replace the dissected portion of the …
-
Μελέτη συσχέτισης παραμέτρων ενδομοσχευμάτων ενδαγγειακής αποκατάστασης ανευρυσμάτων κοιλιακής αορτής με την ευενδοτότητα του αορτικού τοιχώματος
… the patients treated with open surgical repair. Endografts are manufactured by material that is less compliant than the native aortic wall and implantation of them causes decrease in aortic compliance. Increased aortic stiffness is independent prognostic factor for adverse cardiovascular events. …
-
Ενδαγγειακή αποκατάσταση ανευρύσματος κοιλιακής αορτής: μηχανικές ιδιότητες που συμβάλλουν στη στήριξη του ενδομοσχεύματος
… mechanisms within 8 commercially available endografts and compare their fixation ability to each other. Moreover various parameters were validated concerning their influence upon fixation. Methods: 20 human cadaveric aortas were surgically dissected from renals to iliac bifurcations, left in …
-
Vascular Surgery: Physician and Patient Education on Novel Procedures
… for the aging population. Physician-Modified Endografts (PMEGs) are an alternative to traditional open surgery for the repair of TAAAs. The procedure to deploy them is minimally invasive, requiring catheters in the arm and groin rather than a large incision down the midline of the body. They …
-
Hemodynamic mathematical modelling for the evaluation of blood flow in fenestrated, branched and chimney endovascular aortic stent-grafts
… alternative to open surgery but the commercial endografts are not suitable for all thoracic and abdominal aortic aneurysms. The aneurysms with unfavorable morphological features require personalized treatment. Customized endografts preserve their fixation while conforming to hostile aortic …
-
Innovations in the endovascular treatment of complex aortic pathologies
… off-the-shelf, and physician-modified endografts, as well as the durability of bridging stents and renal target vessel preservation. The findings demonstrate high technical success rates, acceptable perioperative risk, and improving mid-term durability across complex anatomies. …
-
Numerical, simulations of blood flow effects under the presence of abdominal aortic aneurysm
… complications is variable among thecommercial endografts. However there are only a few clinical, computational or experimentalstudies, providing hemodynamic data in an endograft-specific manner. Additionally, it isknown that the implantation of an endograft alters hemodynamics with possible …
-
Blood Flow in Dissected Aortas After Thoracic Endovascular Aortic Repair
… one or several implants known as stent-grafts or endografts on the inner surface of the aorta. About 38% of TEVAR procedures come with post-procedural complications and approximately 19% to 24% require secondary re-interventions. Computational fluid dynamics (CFD) simulations can be used as a tool …
-
Η συμβολή της υπολογιστικής μελέτης της Αξονικής αγγειογραφίας στην κατανόηση της συμπεριφοράς του συνδυασμού διχαλωτού ενός - τεμαχίου (unibody) αορτικού ενδομοσχεύματος ePTFE με αορτική προέκταση από Dacron
… – Endurant design, the classic AFX and Endurant endografts, in angulated and non – angulated cases based on patient-specific Computational Fluid Dynamics (CFD) simulations.Methods : 3D endograft models of 11 treated AAA cases were reconstructed from Computed Tomography Angiography (CTA) imaging …
-
Stent-graft behaviour during complex endografting procedures
… are dominated by the radial stiffness of endografts. Furthermore, these phenomena are both spatially and temporally dependent. Indeed, careful selection of both endograft combination and configuration is necessary to improve long-term treatment outcomes associated with the chimney …
-
Μακροχρόνιες μορφομετρικές μεταβολές του κεντρικού, υπονεφρικού αυχένα ανευρισμάτων κοιλιακής αορτής μετά από ενδαγγειακή αποκατάσταση
… standard EVAR with self-expanding abdominal endografts. Patients’ recruitment lasted from 2013 to 2018 and postoperative follow-up was up to five years. A computed tomography angiography (CTA) was performed at first month and then at 1, 2 and 5 years. Proximal aortic neck’s (PAN) basic …
-
Διαδερμική και υβριδική ενδοαυλική αντιμετώπιση νόσων της κατιούσης θωρακικής αορτής και του αορτικού τόξου
… hybrid techniques for placement of aortic endografts in debilitated patients and especially in "hostile anatomies", in which we employ alternative hybrid techniques (e.g., antegrade placement from ascending aorta). Moreover, we analyze complications in postoperative follow-up of patients …
-
Η μακρόχρονη εξέλιξη της ανευρυσματικής νόσου των λαγονίων αρτηριών μετά από ενδαγγειακή αποκατάσταση ανευρύσματος κοιλιακής αορτής
… (FSR, increase by>5mm). Six different bifurcated endografts were implanted, and the main grafts’ feature used to differentiate them into subgroups was the suprarenal fixation with hooks or not. Median follow-up was 77 – 24.0 months and the EVAR-related mortality was 2.4% (n=4). Twenty-seven …
-
Patient dose in the fluoroscopically guided endovascular repair of the abdominal aortic aneurysms
… significantly lower FT. Coronary artery disease, endografts with two docking limbs, AAA diameter, neck angle and length, procedure duration, contrast amount, and hospitalization were associated with significantly higher FT. Neck angle was the single independent perioperative factor related to FT …